09:44:57 #38451 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Tokamak GOLEM for Technical University of Eindhoven 09:44:58 #38451 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 09:44:59 #38451 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 09:45:00 #38451 /GetReadyTheDischarge: Going with gas pressure 10 09:45:00 #38451 /GetReadyTheDischarge: Going with gas type H 09:45:00 #38451 /GetReadyTheDischarge: Diving into .. 09:45:00 #38451 /09:45:00 #38451 /GetReadyTheDischarge: Discharge with 10 mPa req09:45:00 #38451 /G09:45:01 #38451 /VacuumLog: Chamber: 0.90 mPa, 40.80 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 0.00 V orientation CW 09:45:00 #38451 /GetReadyTheDischarge: Discharge with CD CW request 09:45:04 #38451 /VacuumLog: Chamber: 1.55 mPa, 40.60 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 22.91 V 09:45:07 #38451 /GetReadyTheDischarge: Bt capacitor charging started 09:45:08 #38451 /VacuumLog: Chamber: 5.80 mPa, 40.60 C, ForVacuum: 1.85 Pa, Gas: H2, GasValve: 24.22 V 09:45:12 #38451 /VacuumLog: Chamber: 13.00 mPa, 40.60 C, ForVacuum: 3.35 Pa, Gas: H2, GasValve: 23.80 V 09:45:12 #38451 /GetReadyTheDischarge: Cd capacitor charging started 09:45:12 #38451 /ChargingResistorsAllOFF: Diving into .. 09:45:12 #38451 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 09:45:12 #38451 /GetReadyTheDischarge: U_Et: 700, Hrana: 98 09:45:12 #38451 /GetReadyTheDischarge: Charging ... HV=-12 V 09:45:12 #38451 /GetReadyTheDischarge: Charging ... HV=-6 V 09:45:13 #38451 /GetReadyTheDischarge: Charging ... HV=-6 V 09:45:13 #38451 /GetReadyTheDischarge: Charging ... HV=-6 V 09:45:14 #38451 /GetReadyTheDischarge: Charging ... HV=34 V 09:45:14 #38451 /GetReadyTheDischarge: Charging ... HV=34 V 09:45:15 #38451 /GetReadyTheDischarge: Charging ... HV=82 V 09:45:15 #38451 /VacuumLog: Chamber: 13.80 mPa, 40.60 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 22.99 V 09:45:15 #38451 /GetReadyTheDischarge: Charging ... HV=15 V 09:45:16 #38451 /GetReadyTheDischarge: Charging ... HV=128 V 09:45:16 #38451 /GetReadyTheDischarge: Charging ... HV=128 V 09:45:17 #38451 /GetReadyTheDischarge: Charging ... HV=174 V 09:45:17 #38451 /GetReadyTheDischarge: Charging ... HV=174 V 09:45:18 #38451 /GetReadyTheDischarge: Charging ... HV=174 V 09:45:18 #38451 /GetReadyTheDischarge: Charging ... HV=219 V 09:45:19 #38451 /GetReadyTheDischarge: Charging ... HV=219 V 09:45:19 #38451 /GetReadyTheDischarge: Charging ... HV=263 V Gas: H2, GasValve: 22.99 V 09:45:19 #38451 /GetReadyTheDischarge: Charging ... HV=263 V 09:45:20 #38451 /GetReadyTheDischarge: Charging ... HV=308 V 09:45:20 #38451 /GetReadyTheDischarge: Charging ... HV=308 V 09:45:21 #38451 /GetReadyTheDischarge: Charging ... HV=308 V 09:45:21 #38451 /GetReadyTheDischarge: Charging ... HV=349 V 09:45:22 #38451 /GetReadyTheDischarge: Charging ... HV=349 V 09:45:22 #38451 /GetReadyTheDischarge: Charging ... HV=387 V 09:45:23 #38451 /GetReadyTheDischarge: Charging ... HV=387 V 09:45:23 #38451 /GetReadyTheDischarge: Charging ... HV=387 V 09:45:23 #38451 /GetReadyTheDischarge: Charging ... HV=425 V 09:45:24 #38451 /GetReadyTheDischarge: Charging ... HV=425 V 09:45:24 #38451 /GetReadyTheDischarge: Charging ... HV=465 V 09:45:25 #38451 /GetReadyTheDischarge: Charging ... HV=465 V 09:45:25 #38451 /GetReadyTheDischarge: Charging ... HV=465 V 09:45:26 #38451 /GetReadyTheDischarge: Charging ... HV=500 V 09:45:26 #38451 /GetReadyTheDischarge: Charging ... HV=500 V 09:45:26 #38451 /GetReadyTheDischarge: Charging ... HV=535 V 09:45:27 #38451 /GetReadyTheDischarge: Charging ... HV=535 V 09:45:27 #38451 /GetReadyTheDischarge: Charging ... HV=535 V 09:45:28 #38451 /GetReadyTheDischarge: Charging ... HV=571 V 09:45:28 #38451 /GetReadyTheDischarge: Charging ... HV=571 V 09:45:29 #38451 /GetReadyTheDischarge: Charging ... HV=604 V 09:45:29 #38451 /GetReadyTheDischarge: Charging ... HV=604 V 09:45:30 #38451 /GetReadyTheDischarge: Charging ... HV=635 V 09:45:30 #38451 /VacuumLog: Chamber: 11.30 mPa, 40.60 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 22.99 V 09:45:30 #38451 /GetReadyTheDischarge: Charging ... HV=635 V 09:45:30 #38451 /GetReadyTheDischarge: Charging ... HV=635 V 09:45:31 #38451 /GetReadyTheDischarge: Charging ... HV=668 V 09:45:31 #38451 /GetReadyTheDischarge: Charging ... HV=668 V 09:45:32 #38451 /GetReadyTheDischarge: Charging ... HV=701 V 09:45:32 #38451 /GetReadyTheDischarge: Cd capacitor charging finished @ 701 V 09:45:32 #38451 /GetReadyTheDischarge: Charging ... HV=701 V 09:45:33 #38451 /GetReadyTheDischarge: Charging ... HV=701 V 09:45:33 #38451 /GetReadyTheDischarge: Charging ... HV=732 V 09:45:34 #38451 /GetReadyTheDischarge: Charging ... HV=732 V Gas: H2, GasValve: 22.99 V 09:45:34 #38451 /GetReadyTheDischarge: Charging ... HV=763 V 09:45:34 #38451 /GetReadyTheDischarge: Charging ... HV=763 V 09:45:35 #38451 /GetReadyTheDischarge: Charging ... HV=763 V 09:45:35 #38451 /GetReadyTheDischarge: Charging ... HV=794 V 09:45:35 #38451 /GetReadyTheDischarge: Bt slow PowSup 09:45:35 #38451 /ChargingResistorsAllON: Diving into .. 09:45:36 #38451 /GetReadyTheDischarge: Charging ... HV=794 V 09:45:36 #38451 /GetReadyTheDischarge: Charging ... HV=825 V 09:45:37 #38451 /ChargingResistorsAllON: Diving into .. 09:45:37 #38451 /GetReadyTheDischarge: Bt capacitor charging finished @ 825 V 09:45:37 #38451 /ChargingResistorsAllON: Diving into .. 3.85 Pa, Gas: H2, GasValve: 22.99 V 09:45:37 #38451 /GetReadyTheDischarge: Ascending from .. 09:45:37 #38451 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 09:45:39 #38451 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 09:45:39 #38451 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 09:45:39 #38451 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 09:45:41 #38451 /VacuumLog: Chamber: 11.10 mPa, 40.60 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.99 V 09:45:44 #38451 /VacuumLog: Chamber: 11.00 mPa, 40.60 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.99 V 09:45:48 #38451 /VacuumLog: Chamber: 11.00 mPa, 40.60 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.99 V 09:45:50 #38451 /Trigger: Going through .. 09:45:50 #38451 Discharge/HWTrigger: Going through .. 09:45:50 #38451 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 09:45:50 #38451 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 09:45:50 #38451 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 09:45:52 #38451 /VacuumLog: Chamber: 10.90 mPa, 40.60 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 22.99 V 09:45:54 #38451 /ChargingResistorsAllON: Diving into .. 09:45:55 #38451 /VacuumLog: Chamber: 10.90 mPa, 40.60 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 0.00 V 09:45:57 #38451 /SecurePostDischargeState: Going through .. 09:45:57 #38451 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 09:45:59 #38451 /VacuumLog: Chamber: 1.13 mPa, 40.60 C, ForVacuum: 2.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:02 #38451 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 09:46:02 #38451 /VacuumLog: Chamber: 1.06 mPa, 40.70 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 09:46:06 #38451 /VacuumLog: Chamber: 1.02 mPa, 40.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:10 #38451 /VacuumLog: Chamber: 0.99 mPa, 40.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:13 #38451 /VacuumLog: Chamber: 0.98 mPa, 40.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:17 #38451 /VacuumLog: Chamber: 0.96 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:21 #38451 /VacuumLog: Chamber: 0.95 mPa, 40.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:24 #38451 /VacuumLog: Chamber: 0.94 mPa, 40.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:28 #38451 /VacuumLog: Chamber: 0.93 mPa, 40.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:32 #38451 /VacuumLog: Chamber: 0.93 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:35 #38451 /VacuumLog: Chamber: 0.92 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:39 #38451 /VacuumLog: Chamber: 0.92 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:43 #38451 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 09:46:43 #38451 /VacuumLog: Chamber: 0.91 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:46 #38451 /VacuumLog: Chamber: 0.91 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:50 #38451 /VacuumLog: Chamber: 0.90 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:53 #38451 /VacuumLog: Chamber: 0.90 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:46:57 #38451 /VacuumLog: Chamber: 0.90 mPa, 40.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:01 #38451 /VacuumLog: Chamber: 0.90 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:04 #38451 /VacuumLog: Chamber: 0.90 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:08 #38451 /VacuumLog: Chamber: 0.89 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:12 #38451 /VacuumLog: Chamber: 0.89 mPa, 40.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:15 #38451 /VacuumLog: Chamber: 0.89 mPa, 40.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:19 #38451 /VacuumLog: Chamber: 0.89 mPa, 40.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:22 #38451 /VacuumLog: Chamber: 0.89 mPa, 40.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:24 #38451 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 09:47:26 #38451 /VacuumLog: Chamber: 0.89 mPa, 40.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 09:47:28 #38451 /DischargeFunction: General Calling FinalDischargeOperations