08:58:14 #38487 Discharge/PrepareDischargeEnv@SHM: Command Line Request: UPP 08:58:15 #38487 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 08:58:16 #38487 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 08:58:17 #38487 /GetReadyTheDischarge: Going with gas pressure 20 08:58:17 #38487 /GetReadyTheDischarge: Going with gas type H 08:58:17 #38487 /GetReadyTheDischarge: Discharge with Hydrogen request 08:58:17 #38487 /GetReadyTheDischarge: Discharge with 20 mPa request 08:58:17 #38487 /VacuumLog: Chamber: 2.65 mPa, 25.90 C, ForVacuum: 2.05 Pa, Gas: H2, GasValve: 0.00 V ischarge: Going with CD_orientation CW 08:58:17 #38487 /GetReadyTheDischarge: Discharge with CD CW request 08:58:21 #38487 /VacuumLog: Chamber: 9.64 mPa, 26.00 C, ForVacuum: 2.3 Pa, Gas: H2, GasValve: 25.64 V 08:58:24 #38487 /GetReadyTheDischarge: Bt capacitor charging started 08:58:25 #38487 /VacuumLog: Chamber: 23.20 mPa, 26.10 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 21.71 V 08:58:28 #38487 /VacuumLog: Chamber: 21.20 mPa, 26.10 C, ForVacuum: 5.35 Pa, Gas: H2, GasValve: 23.03 V 08:58:28 #38487 /GetReadyTheDischarge: Cd capacitor charging started 08:58:28 #38487 /ChargingResistorsAllOFF: Diving into .. 08:58:29 #38487 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 08:58:29 #38487 /GetReadyTheDischarge: U_Et: 400, Hrana: 98 08:58:29 #38487 /GetReadyTheDischarge: Charging ... HV=-9 V 08:58:29 #38487 /GetReadyTheDischarge: Charging ... HV=-9 V 08:58:30 #38487 /GetReadyTheDischarge: Charging ... HV=-9 V 08:58:30 #38487 /GetReadyTheDischarge: Charging ... HV=23 V 08:58:31 #38487 /GetReadyTheDischarge: Charging ... HV=23 V 08:58:31 #38487 /GetReadyTheDischarge: Charging ... HV=23 V 08:58:31 #38487 /GetReadyTheDischarge: Charging ... HV=73 V 08:58:32 #38487 /GetReadyTheDischarge: Charging ... HV=73 V , Gas: H2, GasValve: 22.69 V 08:58:32 #38487 /GetReadyTheDischarge: Charging ... HV=120 V 08:58:33 #38487 /GetReadyTheDischarge: Charging ... HV=120 V 08:58:33 #38487 /GetReadyTheDischarge: Charging ... HV=167 V 08:58:34 #38487 /GetReadyTheDischarge: Charging ... HV=167 V 08:58:34 #38487 /GetReadyTheDischarge: Charging ... HV=167 V 08:58:35 #38487 /GetReadyTheDischarge: Charging ... HV=213 V 08:58:35 #38487 /GetReadyTheDischarge: Charging ... HV=213 V 08:58:35 #38487 /GetReadyTheDischarge: Charging ... HV=259 V 08:58:36 #38487 /GetReadyTheDischarge: Charging ... HV=259 V Gas: H2, GasValve: 22.69 V 08:58:36 #38487 /GetReadyTheDischarge: Charging ... HV=259 V 08:58:37 #38487 /GetReadyTheDischarge: Charging ... HV=14 V 08:58:37 #38487 /GetReadyTheDischarge: Charging ... HV=304 V 08:58:38 #38487 /GetReadyTheDischarge: Charging ... HV=346 V 08:58:38 #38487 /GetReadyTheDischarge: Charging ... HV=346 V 08:58:38 #38487 /GetReadyTheDischarge: Charging ... HV=346 V 08:58:39 #38487 /GetReadyTheDischarge: Charging ... HV=385 V 08:58:39 #38487 /GetReadyTheDischarge: Charging ... HV=385 V 08:58:40 #38487 /GetReadyTheDischarge: Charging ... HV=424 V 08:58:40 #38487 /GetReadyTheDischarge: Cd capacitor charging finished @ 424 V 08:58:40 #38487 /GetReadyTheDischarge: Charging ... HV=424 V 08:58:41 #38487 /GetReadyTheDischarge: Charging ... HV=465 V 08:58:41 #38487 /GetReadyTheDischarge: Charging ... HV=465 V 08:58:42 #38487 /GetReadyTheDischarge: Charging ... HV=465 V 08:58:42 #38487 /GetReadyTheDischarge: Charging ... HV=505 V 08:58:42 #38487 /GetReadyTheDischarge: Charging ... HV=505 V 08:58:43 #38487 /GetReadyTheDischarge: Charging ... HV=544 V 08:58:43 #38487 /GetReadyTheDischarge: Charging ... HV=544 V 08:58:44 #38487 /GetReadyTheDischarge: Charging ... HV=14 V 08:58:44 #38487 /GetReadyTheDischarge: Charging ... HV=584 V 08:58:45 #38487 /GetReadyTheDischarge: Charging ... HV=584 V 08:58:45 #38487 /GetReadyTheDischarge: Charging ... HV=584 V 08:58:45 #38487 /GetReadyTheDischarge: Charging ... HV=620 V 08:58:46 #38487 /GetReadyTheDischarge: Charging ... HV=620 V 08:58:46 #38487 /GetReadyTheDischarge: Charging ... HV=14 V 08:58:47 #38487 /GetReadyTheDischarge: Charging ... HV=656 V 08:58:47 #38487 /GetReadyTheDischarge: Charging ... HV=656 V 08:58:48 #38487 /GetReadyTheDischarge: Charging ... HV=694 V 08:58:48 #38487 /GetReadyTheDischarge: Charging ... HV=694 V 08:58:48 #38487 /GetReadyTheDischarge: Charging ... HV=728 V 08:58:49 #38487 /GetReadyTheDischarge: Charging ... HV=728 V 08:58:49 #38487 /GetReadyTheDischarge: Charging ... HV=728 V 08:58:50 #38487 /GetReadyTheDischarge: Charging ... HV=760 V 08:58:50 #38487 /VacuumLog: Chamber: 19.60 mPa, 26.10 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 22.69 V 08:58:50 #38487 /GetReadyTheDischarge: Charging ... HV=760 V 08:58:50 #38487 /GetReadyTheDischarge: Charging ... HV=792 V 08:58:51 #38487 /GetReadyTheDischarge: Bt slow PowSup 08:58:51 #38487 /ChargingResistorsAllON: Diving into .. 08:58:51 #38487 /GetReadyTheDischarge: Charging ... HV=792 V 08:58:51 #38487 /GetReadyTheDischarge: Charging ... HV=820 V 08:58:52 #38487 /ChargingResistorsAllON: Diving into .. 08:58:52 #38487 /GetReadyTheDischarge: Bt capacitor charging finished @ 820 V 08:58:52 #38487 /ChargingResistorsAllON: Diving into .. 08:58:53 #38487 /GetReadyTheDischarge: Ascending from .. 08:58:53 #38487 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 08:58:54 #38487 /VacuumLog: Chamber: 19.70 mPa, 26.00 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 22.69 V 08:58:54 #38487 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 08:58:54 #38487 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 08:58:54 #38487 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 08:58:57 #38487 /VacuumLog: Chamber: 19.90 mPa, 26.10 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 22.69 V 08:59:01 #38487 /VacuumLog: Chamber: 20.10 mPa, 26.00 C, ForVacuum: 5.3 Pa, Gas: H2, GasValve: 22.69 V 08:59:05 #38487 /VacuumLog: Chamber: 20.30 mPa, 26.20 C, ForVacuum: 5.3 Pa, Gas: H2, GasValve: 22.69 V 08:59:05 #38487 /Trigger: Going through .. 08:59:05 #38487 Discharge/HWTrigger: Going through .. 08:59:05 #38487 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 08:59:05 #38487 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 08:59:05 #38487 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 08:59:08 #38487 /VacuumLog: Chamber: 18.20 mPa, 26.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 22.69 V 08:59:10 #38487 /ChargingResistorsAllON: Diving into .. 08:59:12 #38487 /VacuumLog: Chamber: 6.24 mPa, 26.20 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 0.00 V 08:59:12 #38487 /SecurePostDischargeState: Going through .. 08:59:12 #38487 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 08:59:15 #38487 /VacuumLog: Chamber: 3.05 mPa, 26.20 C, ForVacuum: 2.5 Pa, Gas: NULL, GasValve: 0.00 V 08:59:17 #38487 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 08:59:19 #38487 /VacuumLog: Chamber: 2.87 mPa, 26.20 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 08:59:23 #38487 /VacuumLog: Chamber: 2.77 mPa, 26.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:26 #38487 /VacuumLog: Chamber: 2.70 mPa, 26.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:30 #38487 /VacuumLog: Chamber: 2.64 mPa, 26.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:34 #38487 /VacuumLog: Chamber: 2.60 mPa, 26.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:37 #38487 /VacuumLog: Chamber: 2.57 mPa, 26.30 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:41 #38487 /VacuumLog: Chamber: 2.55 mPa, 26.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:44 #38487 /VacuumLog: Chamber: 2.53 mPa, 26.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:46 #38487 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 08:59:48 #38487 /VacuumLog: Chamber: 2.51 mPa, 26.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:52 #38487 /VacuumLog: Chamber: 2.49 mPa, 26.40 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:55 #38487 /VacuumLog: Chamber: 2.48 mPa, 26.30 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 08:59:57 #38487 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 08:59:59 #38487 /VacuumLog: Chamber: 2.46 mPa, 26.30 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 09:00:03 #38487 /VacuumLog: Chamber: 2.45 mPa, 26.30 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 09:00:04 #38487 /DischargeFunction: General Calling FinalDischargeOperations