18:48:28 #38518 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Strip detector commissioning 18:48:28 #38518 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 18:48:30 #38518 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 18:48:30 #38518 /GetReadyTheDischarge: Going with gas pressure 20 18:48:30 #38518 /GetReadyTheDischarge: Going with gas type H 18:48:30 #38518 /GetReadyTheDischarge: Discharge with Hydrogen request 18:48:30 #38518 /GetReadyTheDischarge: Discharge with 20 mPa request 18:48:30 #38518 /VacuumLog: Chamber: 0.99 mPa, 31.20 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 0.00 V harge: Going with Bt_orientation CW 18:48:30 #38518 /GetReadyTheDischarge: Discharge with Bt CW request 18:48:30 #38518 /GetReadyTheDischarge: Going with CD_orientation CW 18:48:31 #38518 /GetReadyTheDischarge: Discharge with CD CW request 18:48:34 #38518 /VacuumLog: Chamber: 16.60 mPa, 31.10 C, ForVacuum: 1.7 Pa, Gas: H2, GasValve: 24.54 V 18:48:37 #38518 /GetReadyTheDischarge: Bt capacitor charging started 18:48:38 #38518 /VacuumLog: Chamber: 12.10 mPa, 31.20 C, ForVacuum: 5.45 Pa, Gas: H2, GasValve: 20.60 V 18:48:41 #38518 /VacuumLog: Chamber: 23.30 mPa, 31.10 C, ForVacuum: 4.95 Pa, Gas: H2, GasValve: 22.11 V 18:48:42 #38518 /GetReadyTheDischarge: Cd capacitor charging started 18:48:42 #38518 /ChargingResistorsAllOFF: Diving into .. 18:48:42 #38518 /GetReadyTheDischarge: U_Bt: 700, Hrana: 98 18:48:42 #38518 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 18:48:42 #38518 /GetReadyTheDischarge: Charging ... HV=-14 V 18:48:43 #38518 /GetReadyTheDischarge: Charging ... HV=-10 V 18:48:43 #38518 /GetReadyTheDischarge: Charging ... HV=-10 V 18:48:43 #38518 /GetReadyTheDischarge: Charging ... HV=25 V 18:48:44 #38518 /GetReadyTheDischarge: Charging ... HV=25 V 18:48:44 #38518 /GetReadyTheDischarge: Charging ... HV=25 V 18:48:45 #38518 /GetReadyTheDischarge: Charging ... HV=74 V 18:48:45 #38518 /GetReadyTheDischarge: Charging ... HV=74 V , Gas: H2, GasValve: 21.64 V 18:48:46 #38518 /GetReadyTheDischarge: Charging ... HV=120 V 18:48:46 #38518 /GetReadyTheDischarge: Charging ... HV=120 V 18:48:46 #38518 /GetReadyTheDischarge: Charging ... HV=120 V 18:48:47 #38518 /GetReadyTheDischarge: Charging ... HV=168 V 18:48:47 #38518 /GetReadyTheDischarge: Charging ... HV=168 V 18:48:48 #38518 /GetReadyTheDischarge: Charging ... HV=215 V 18:48:48 #38518 /GetReadyTheDischarge: Charging ... HV=215 V 18:48:49 #38518 /GetReadyTheDischarge: Charging ... HV=215 V 18:48:49 #38518 /GetReadyTheDischarge: Charging ... HV=261 V 18:48:50 #38518 /GetReadyTheDischarge: Charging ... HV=261 V 18:48:50 #38518 /GetReadyTheDischarge: Charging ... HV=306 V 18:48:50 #38518 /GetReadyTheDischarge: Charging ... HV=0 V 18:48:51 #38518 /GetReadyTheDischarge: Charging ... HV=306 V 18:48:51 #38518 /GetReadyTheDischarge: Charging ... HV=348 V 18:48:52 #38518 /GetReadyTheDischarge: Charging ... HV=348 V 18:48:52 #38518 /VacuumLog: Chamber: 19.80 mPa, 31.20 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 21.64 V 18:48:52 #38518 /GetReadyTheDischarge: Charging ... HV=388 V 18:48:53 #38518 /GetReadyTheDischarge: Charging ... HV=388 V 18:48:53 #38518 /GetReadyTheDischarge: Charging ... HV=427 V 18:48:54 #38518 /GetReadyTheDischarge: Charging ... HV=427 V 18:48:54 #38518 /GetReadyTheDischarge: Charging ... HV=427 V 18:48:54 #38518 /GetReadyTheDischarge: Charging ... HV=468 V 18:48:55 #38518 /GetReadyTheDischarge: Charging ... HV=468 V 18:48:55 #38518 /GetReadyTheDischarge: Charging ... HV=505 V 18:48:55 #38518 /GetReadyTheDischarge: Cd capacitor charging finished @ 505 V 18:48:56 #38518 /GetReadyTheDischarge: Charging ... HV=0 V Pa, Gas: H2, GasValve: 21.64 V 18:48:56 #38518 /GetReadyTheDischarge: Charging ... HV=505 V 18:48:57 #38518 /GetReadyTheDischarge: Charging ... HV=542 V 18:48:57 #38518 /GetReadyTheDischarge: Charging ... HV=542 V 18:48:57 #38518 /GetReadyTheDischarge: Charging ... HV=581 V 18:48:58 #38518 /GetReadyTheDischarge: Charging ... HV=581 V 18:48:58 #38518 /GetReadyTheDischarge: Charging ... HV=581 V 18:48:59 #38518 /GetReadyTheDischarge: Charging ... HV=618 V 18:48:59 #38518 /GetReadyTheDischarge: Charging ... HV=618 V 18:49:00 #38518 /GetReadyTheDischarge: Charging ... HV=653 V , Gas: H2, GasValve: 21.64 V 18:49:00 #38518 /GetReadyTheDischarge: Charging ... HV=653 V 18:49:00 #38518 /GetReadyTheDischarge: Charging ... HV=653 V 18:49:01 #38518 /GetReadyTheDischarge: Charging ... HV=692 V 18:49:01 #38518 /GetReadyTheDischarge: Bt slow PowSup 18:49:01 #38518 /ChargingResistorsAllON: Diving into .. 18:49:01 #38518 /GetReadyTheDischarge: Charging ... HV=692 V 18:49:02 #38518 /GetReadyTheDischarge: Charging ... HV=725 V 18:49:02 #38518 /ChargingResistorsAllON: Diving into .. 18:49:02 #38518 /GetReadyTheDischarge: Bt capacitor charging finished @ 725 V 18:49:03 #38518 /ChargingResistorsAllON: Diving into .. 18:49:03 #38518 /GetReadyTheDischarge: Ascending from .. 18:49:03 #38518 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 18:49:03 #38518 /VacuumLog: Chamber: 19.50 mPa, 31.20 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 21.64 V 18:49:05 #38518 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:49:05 #38518 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:49:05 #38518 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_MT action on stage with Arming 18:49:07 #38518 /VacuumLog: Chamber: 19.50 mPa, 31.20 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 21.64 V 18:49:10 #38518 /VacuumLog: Chamber: 19.50 mPa, 31.20 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 21.64 V 18:49:14 #38518 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 18:49:14 #38518 /VacuumLog: Chamber: 19.50 mPa, 31.20 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 21.64 V 18:49:18 #38518 /VacuumLog: Chamber: 19.50 mPa, 31.20 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 21.64 V 18:49:21 #38518 /VacuumLog: Chamber: 19.60 mPa, 31.20 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 21.64 V 18:49:24 #38518 /Trigger: Going through .. 18:49:24 #38518 Discharge/HWTrigger: Going through .. 18:49:24 #38518 Discharge/HWTrigger: Going with trigger Tch3 - TBt 5000 18:49:24 #38518 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 18:49:24 #38518 Discharge/HWTrigger: Going with trigger Tch5 - Tist -1000 18:49:25 #38518 /VacuumLog: Chamber: 19.70 mPa, 31.20 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 21.64 V 18:49:28 #38518 /ChargingResistorsAllON: Diving into .. 18:49:29 #38518 /VacuumLog: Chamber: 20.20 mPa, 31.20 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 21.64 V 18:49:31 #38518 /SecurePostDischargeState: Going through .. 18:49:31 #38518 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 18:49:32 #38518 /VacuumLog: Chamber: 1.61 mPa, 31.20 C, ForVacuum: 3.4 Pa, Gas: NULL, GasValve: 0.00 V 18:49:36 #38518 /VacuumLog: Chamber: 1.30 mPa, 31.30 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 18:49:36 #38518 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 18:49:39 #38518 /VacuumLog: Chamber: 1.22 mPa, 31.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 18:49:43 #38518 /VacuumLog: Chamber: 1.17 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:49:47 #38518 /VacuumLog: Chamber: 1.13 mPa, 31.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:49:50 #38518 /VacuumLog: Chamber: 1.10 mPa, 31.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:49:54 #38518 /VacuumLog: Chamber: 1.08 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:49:58 #38518 /VacuumLog: Chamber: 1.06 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:01 #38518 /VacuumLog: Chamber: 1.05 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:05 #38518 /VacuumLog: Chamber: 1.03 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:09 #38518 /VacuumLog: Chamber: 1.02 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:12 #38518 /VacuumLog: Chamber: 1.01 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:16 #38518 /VacuumLog: Chamber: 1.01 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:20 #38518 /VacuumLog: Chamber: 1.00 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:23 #38518 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 18:50:23 #38518 /VacuumLog: Chamber: 1.00 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:27 #38518 /VacuumLog: Chamber: 0.99 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:31 #38518 /VacuumLog: Chamber: 0.99 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:34 #38518 /VacuumLog: Chamber: 0.99 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:38 #38518 /VacuumLog: Chamber: 0.99 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:41 #38518 /VacuumLog: Chamber: 0.99 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:45 #38518 /VacuumLog: Chamber: 0.99 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:49 #38518 /VacuumLog: Chamber: 0.98 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:52 #38518 /VacuumLog: Chamber: 0.98 mPa, 31.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:50:54 #38518 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 18:50:56 #38518 /VacuumLog: Chamber: 0.98 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:51:00 #38518 /VacuumLog: Chamber: 0.98 mPa, 31.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:51:00 #38518 /DischargeFunction: General Calling FinalDischargeOperations