\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #38547

Tokamak GOLEM - Shot Database - #38547

The date of discharge execution22-04-06 19:09:32 [Shot logbook]
The session mission22 --> Plasma position stabilization
The session ID38538
The discharge commentvert stab -20
Discharge command./Dirigent.sh --discharge --UBt 1200 --TBt 0 --Ucd 450 --Tcd 350 --preionization 1 --gas H --pressure 6 --diagnostics.limitermirnovcoils "vacuum_shot=38525" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-20;20000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;6000,0;22000,-2;25000,0'" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --ScanDefinition "38544 38545" --comment "vert stab -20"

     Technological parameters

    Plasma:

    Plasma parameters:

Basic Diagnostics    

On stage diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



         



 



         



 



Other diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



Analysis

NameAnalysis results

Infrastructure

main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-20;20000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;6000,0;22000,-2;25000,0'




Scan issues

for 38544 38545 + 38547







#38544     ./Dirigent.sh --discharge --UBt 1200 --TBt 0 --Ucd 450 --Tcd 350 --preionization 1 --gas H --pressure 6 --diagnostics.limitermirnovcoils "vacuum_shot=38525" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-20;20000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;9000,-15;22000,-2;25000,0'" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --ScanDefinition "38540 38541 38542" --comment "vert stab -20 rad stab -15"
#38545     ./Dirigent.sh --discharge --UBt 1200 --TBt 0 --Ucd 450 --Tcd 350 --preionization 1 --gas H --pressure 6 --diagnostics.limitermirnovcoils "vacuum_shot=38525" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-20;20000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;9000,-20;22000,-2;25000,0'" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --ScanDefinition "38540 38541 38542" --comment "vert stab -20 rad stab -20"
#38547     ./Dirigent.sh --discharge --UBt 1200 --TBt 0 --Ucd 450 --Tcd 350 --preionization 1 --gas H --pressure 6 --diagnostics.limitermirnovcoils "vacuum_shot=38525" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-20;20000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;6000,0;22000,-2;25000,0'" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --ScanDefinition "38544 38545" --comment "vert stab -20"

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

Other

Navigation