22:09:36 #38555 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 22:09:36 #38555 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 22:09:38 #38555 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 22:09:38 #38555 /GetReadyTheDischarge: Going with gas pressure 10 22:09:38 #38555 /GetReadyTheDischarge: Going with gas type H 22:09:38 22:09:38 #38555 /GetReadyTheDischarge: Discharge with Hydrogen request 22:09:38 #38555 /GetReadyTheDischarge: Discharge with 10 mPa request 22:09:38 #38555 /GetReadyTheDischarge: Going with CD_orientation CW 22:09:38 #38555 /GetReadyTheDischarge: Discharge with CD CW request 22:09:42 #38555 /VacuumLog: Chamber: 1.03 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 22.05 V 22:09:45 #38555 /GetReadyTheDischarge: Bt capacitor charging started 22:09:45 #38555 /VacuumLog: Chamber: 5.25 mPa, 33.30 C, ForVacuum: 1.55 Pa, Gas: H2, GasValve: 24.20 V 22:09:49 #38555 /VacuumLog: Chamber: 11.60 mPa, 33.20 C, ForVacuum: 2.85 Pa, Gas: H2, GasValve: 24.38 V 22:09:50 #38555 /GetReadyTheDischarge: Cd capacitor charging started 22:09:50 #38555 /ChargingResistorsAllOFF: Diving into .. 22:09:50 #38555 /GetReadyTheDischarge: U_Bt: 220, Hrana: 98 22:09:50 #38555 /GetReadyTheDischarge: U_Et: 220, Hrana: 98 22:09:50 #38555 /GetReadyTheDischarge: Charging ... HV=-10 V 22:09:50 #38555 /GetReadyTheDischarge: Charging ... HV=-10 V 22:09:51 #38555 /GetReadyTheDischarge: Charging ... HV=2 V 22:09:51 #38555 /GetReadyTheDischarge: Charging ... HV=2 V 22:09:52 #38555 /GetReadyTheDischarge: Charging ... HV=47 V 22:09:52 #38555 /GetReadyTheDischarge: Charging ... HV=47 V 22:09:53 #38555 /GetReadyTheDischarge: Charging ... HV=47 V 22:09:53 #38555 /GetReadyTheDischarge: Charging ... HV=4 V Pa, Gas: H2, GasValve: 23.08 V 22:09:53 #38555 /GetReadyTheDischarge: Charging ... HV=96 V 22:09:54 #38555 /GetReadyTheDischarge: Charging ... HV=142 V 22:09:54 #38555 /GetReadyTheDischarge: Charging ... HV=142 V 22:09:55 #38555 /GetReadyTheDischarge: Charging ... HV=142 V 22:09:55 #38555 /GetReadyTheDischarge: Charging ... HV=189 V 22:09:56 #38555 /GetReadyTheDischarge: Charging ... HV=189 V 22:09:56 #38555 /GetReadyTheDischarge: Charging ... HV=236 V 22:09:56 #38555 /GetReadyTheDischarge: Bt capacitor charging finished @ 236 V 22:09:57 #38555 /ChargingResistorsAllON: Diving into .. 22:09:57 #38555 /GetReadyTheDischarge: Cd capacitor charging finished @ 236 V 22:09:57 #38555 /ChargingResistorsAllON: Diving into .. 22:09:57 #38555 /GetReadyTheDischarge: Ascending from .. 22:09:57 #38555 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 22:09:59 #38555 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 22:09:59 #38555 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 22:10:00 #38555 /VacuumLog: Chamber: 10.10 mPa, 33.20 C, ForVacuum: 3.65 Pa, Gas: H2, GasValve: 23.08 V 22:10:01 #38555 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 22:10:04 #38555 /VacuumLog: Chamber: 10.00 mPa, 33.20 C, ForVacuum: 3.6 Pa, Gas: H2, GasValve: 23.08 V 22:10:07 #38555 /VacuumLog: Chamber: 9.96 mPa, 33.20 C, ForVacuum: 3.6 Pa, Gas: H2, GasValve: 23.08 V 22:10:11 #38555 /VacuumLog: Chamber: 9.91 mPa, 33.20 C, ForVacuum: 3.6 Pa, Gas: H2, GasValve: 23.08 V 22:10:12 #38555 /Trigger: Going through .. 22:10:12 #38555 Discharge/HWTrigger: Going through .. 22:10:12 #38555 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 22:10:12 #38555 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 22:10:12 #38555 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 22:10:15 #38555 /VacuumLog: Chamber: 9.84 mPa, 33.20 C, ForVacuum: 3.6 Pa, Gas: H2, GasValve: 23.08 V 22:10:16 #38555 /ChargingResistorsAllON: Diving into .. 22:10:18 #38555 /VacuumLog: Chamber: 5.12 mPa, 33.20 C, ForVacuum: 3.5 Pa, Gas: H2, GasValve: 0.00 V 22:10:19 #38555 /SecurePostDischargeState: Going through .. 22:10:19 #38555 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 22:10:22 #38555 /VacuumLog: Chamber: 0.93 mPa, 33.20 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 22:10:24 #38555 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 22:10:25 #38555 /VacuumLog: Chamber: 0.89 mPa, 33.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 22:10:29 #38555 /VacuumLog: Chamber: 0.88 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:33 #38555 /VacuumLog: Chamber: 0.88 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:35 #38555 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 22:10:36 #38555 /VacuumLog: Chamber: 0.88 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:40 #38555 /VacuumLog: Chamber: 0.89 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:44 #38555 /VacuumLog: Chamber: 0.89 mPa, 33.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:47 #38555 /VacuumLog: Chamber: 0.89 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:51 #38555 /VacuumLog: Chamber: 0.89 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:54 #38555 /VacuumLog: Chamber: 0.90 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:10:58 #38555 /VacuumLog: Chamber: 0.90 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:11:02 #38555 /VacuumLog: Chamber: 0.90 mPa, 33.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:11:05 #38555 /VacuumLog: Chamber: 0.90 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:11:09 #38555 /VacuumLog: Chamber: 0.90 mPa, 33.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:11:10 #38555 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 22:11:13 #38555 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:11:13 #38555 /DischargeFunction: General Calling FinalDischargeOperations