12:15:49 #38592 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 12:15:49 #38592 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 12:15:50 #38592 /VacuumLog: Chamber: 1.21 mPa, 28.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 12:15:51 #38592 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 12:15:51 #38592 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 12:15:51 #38592 /GetReadyTheDischarge: Diving into .. 12:15:51 #38592 /GetReadyTheDischarge: Going with Bt_orientation CW 1212:15:51 #38592 /GetReadyTheDischarge: Discharge with Bt CW request 12:15:51 12:15:51 #38592 /GetReadyTheDischarge: Going with CD_orientation CW 12:15:51 #38592 /GetReadyTheDischarge: Discharge with CD CW request 12:15:54 #38592 /VacuumLog: Chamber: 1.75 mPa, 28.50 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 22.13 V 12:15:57 #38592 /VacuumLog: Chamber: 33.30 mPa, 28.60 C, ForVacuum: 3.1 Pa, Gas: H2, GasValve: 21.34 V 12:15:58 #38592 /GetReadyTheDischarge: Bt capacitor charging started 12:16:01 #38592 /VacuumLog: Chamber: 12.60 mPa, 28.60 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 21.48 V 12:16:03 #38592 /GetReadyTheDischarge: Cd capacitor charging started 12:16:03 #38592 /ChargingResistorsAllOFF: Diving into .. 12:16:03 #38592 /GetReadyTheDischarge: U_Bt: 600, Hrana: 98 12:16:03 #38592 /GetReadyTheDischarge: U_Et: 400, Hrana: 98 12:16:03 #38592 /GetReadyTheDischarge: Charging ... HV=-12 V 12:16:04 #38592 /GetReadyTheDischarge: Charging ... HV=-12 V 12:16:04 #38592 /GetReadyTheDischarge: Charging ... HV=2 V 12:16:05 #38592 /GetReadyTheDischarge: Charging ... HV=2 V 12:16:05 #38592 /GetReadyTheDischarge: Charging ... HV=48 V 12:16:05 #38592 /GetReadyTheDischarge: Charging ... HV=48 V 12:16:06 #38592 /GetReadyTheDischarge: Charging ... HV=48 V 12:16:06 #38592 /GetReadyTheDischarge: Charging ... HV=97 V 12:16:07 #38592 /GetReadyTheDischarge: Charging ... HV=97 V 12:16:07 #38592 /GetReadyTheDischarge: Charging ... HV=143 V 12:16:08 #38592 /GetReadyTheDischarge: Charging ... HV=143 V 12:16:08 #38592 /GetReadyTheDischarge: Charging ... HV=143 V 12:16:08 #38592 /GetReadyTheDischarge: Charging ... HV=190 V 12:16:09 #38592 /GetReadyTheDischarge: Charging ... HV=190 V 12:16:09 #38592 /GetReadyTheDischarge: Charging ... HV=236 V 12:16:10 #38592 /GetReadyTheDischarge: Charging ... HV=236 V 12:16:10 #38592 /GetReadyTheDischarge: Charging ... HV=236 V 12:16:11 #38592 /GetReadyTheDischarge: Charging ... HV=280 V 12:16:11 #38592 /GetReadyTheDischarge: Charging ... HV=280 V 12:16:12 #38592 /GetReadyTheDischarge: Charging ... HV=325 V 12:16:12 #38592 /VacuumLog: Chamber: 14.80 mPa, 28.60 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 21.58 V 12:16:12 #38592 /GetReadyTheDischarge: Charging ... HV=325 V 12:16:12 #38592 /GetReadyTheDischarge: Charging ... HV=325 V 12:16:13 #38592 /GetReadyTheDischarge: Charging ... HV=365 V 12:16:13 #38592 /GetReadyTheDischarge: Charging ... HV=365 V 12:16:14 #38592 /GetReadyTheDischarge: Charging ... HV=404 V 12:16:14 #38592 /GetReadyTheDischarge: Cd capacitor charging finished @ 404 V 12:16:14 #38592 /GetReadyTheDischarge: Charging ... HV=404 V 12:16:15 #38592 /GetReadyTheDischarge: Charging ... HV=444 V 12:16:15 #38592 /GetReadyTheDischarge: Charging ... HV=444 V 12:16:15 #38592 /GetReadyTheDischarge: Charging ... HV=444 V Gas: H2, GasValve: 21.58 V 12:16:16 #38592 /GetReadyTheDischarge: Charging ... HV=486 V 12:16:16 #38592 /GetReadyTheDischarge: Charging ... HV=486 V 12:16:17 #38592 /GetReadyTheDischarge: Charging ... HV=526 V 12:16:17 #38592 /GetReadyTheDischarge: Charging ... HV=526 V 12:16:18 #38592 /GetReadyTheDischarge: Charging ... HV=526 V 12:16:18 #38592 /GetReadyTheDischarge: Charging ... HV=565 V 12:16:18 #38592 /GetReadyTheDischarge: Charging ... HV=565 V 12:16:19 #38592 /GetReadyTheDischarge: Charging ... HV=565 V 12:16:19 #38592 /GetReadyTheDischarge: Charging ... HV=602 V , Gas: H2, GasValve: 21.58 V 12:16:20 #38592 /ChargingResistorsAllON: Diving into .. 12:16:20 #38592 /GetReadyTheDischarge: Bt capacitor charging finished @ 602 V 12:16:20 #38592 /ChargingResistorsAllON: Diving into .. 12:16:20 #38592 /GetReadyTheDischarge: Ascending from .. 12:16:20 #38592 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 12:16:22 #38592 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:16:22 #38592 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:16:23 #38592 /VacuumLog: Chamber: 14.30 mPa, 28.50 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 21.58 V 12:16:24 #38592 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 12:16:26 #38592 /VacuumLog: Chamber: 14.20 mPa, 28.50 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.58 V 12:16:30 #38592 /VacuumLog: Chamber: 14.10 mPa, 28.50 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.58 V 12:16:34 #38592 /VacuumLog: Chamber: 14.00 mPa, 28.50 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.58 V 12:16:35 #38592 /Trigger: Going through .. 12:16:35 #38592 Discharge/HWTrigger: Going through .. 12:16:35 #38592 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 12:16:35 #38592 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 12:16:35 #38592 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 12:16:37 #38592 /VacuumLog: Chamber: 12.70 mPa, 28.50 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 21.58 V 12:16:39 #38592 /ChargingResistorsAllON: Diving into .. 12:16:41 #38592 /VacuumLog: Chamber: 6.89 mPa, 28.50 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 0.00 V 12:16:42 #38592 /SecurePostDischargeState: Going through .. 12:16:42 #38592 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 12:16:45 #38592 /VacuumLog: Chamber: 1.49 mPa, 28.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 12:16:47 #38592 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 12:16:48 #38592 /VacuumLog: Chamber: 1.39 mPa, 28.60 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 12:16:52 #38592 /VacuumLog: Chamber: 1.34 mPa, 28.60 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 12:16:56 #38592 /VacuumLog: Chamber: 1.30 mPa, 28.60 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 12:16:59 #38592 /VacuumLog: Chamber: 1.28 mPa, 28.60 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 12:17:03 #38592 /VacuumLog: Chamber: 1.26 mPa, 28.60 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:17:06 #38592 /VacuumLog: Chamber: 1.25 mPa, 28.60 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V 12:17:10 #38592 /VacuumLog: Chamber: 1.24 mPa, 28.60 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V 12:17:12 #38592 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 12:17:14 #38592 /VacuumLog: Chamber: 1.23 mPa, 28.60 C, ForVacuum: 0.99 Pa, Gas: NULL, GasValve: 0.00 V 12:17:17 #38592 /VacuumLog: Chamber: 1.23 mPa, 28.60 C, ForVacuum: 0.99 Pa, Gas: NULL, GasValve: 0.00 V 12:17:21 #38592 /VacuumLog: Chamber: 1.22 mPa, 28.60 C, ForVacuum: 0.99 Pa, Gas: NULL, GasValve: 0.00 V 12:17:25 #38592 /VacuumLog: Chamber: 1.22 mPa, 28.60 C, ForVacuum: 0.99 Pa, Gas: NULL, GasValve: 0.00 V 12:17:28 #38592 /VacuumLog: Chamber: 1.22 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:32 #38592 /VacuumLog: Chamber: 1.22 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:36 #38592 /VacuumLog: Chamber: 1.22 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:39 #38592 /VacuumLog: Chamber: 1.22 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:43 #38592 /VacuumLog: Chamber: 1.21 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:47 #38592 /VacuumLog: Chamber: 1.21 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:48 #38592 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 12:17:50 #38592 /VacuumLog: Chamber: 1.21 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:54 #38592 /VacuumLog: Chamber: 1.21 mPa, 28.60 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 12:17:55 #38592 /DischargeFunction: General Calling FinalDischargeOperations