12:29:20 #38628 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 12:29:20 #38628 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 12:29:20 #38628 /VacuumLog: Chamber: 0.91 mPa, 34.50 C, ForVacuum: 0.875 Pa, Gas: NULL, GasValve: 0.00 V 12:29:22 #38628 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 12:29:22 #38628 /GetReadyTheDischarge: Going with gas pressure 24 12:29:22 #38628 /GetReadyTheDischarge: Going with gas type H 12:29:22 #38628 /GetReadyTheDischarge: Discharge with Hydrogen request 12:29:22 #38628 /GetReadyTheDischarge: Discharge with 24 mPa request 29:22 #38628 /GetReadyTheDischarge: Going with Bt_orientation CW 12:29:22 #38628 /GetReadyTheDischarge: Discharge with Bt CW request 12:29:22 #38628 /GetReadyTheDischarge: Going with CD_orientation CW 12:29:23 #38628 /GetReadyTheDischarge: Discharge with CD CW request 12:29:24 #38628 /VacuumLog: Chamber: 0.92 mPa, 34.50 C, ForVacuum: 0.875 Pa, Gas: H2, GasValve: 23.55 V 12:29:28 #38628 /VacuumLog: Chamber: 97.50 mPa, 34.50 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 18.76 V 12:29:29 #38628 /GetReadyTheDischarge: Bt capacitor charging started 12:29:31 #38628 /VacuumLog: Chamber: 12.50 mPa, 34.50 C, ForVacuum: 5.05 Pa, Gas: H2, GasValve: 23.43 V 12:29:34 #38628 /GetReadyTheDischarge: Cd capacitor charging started 12:29:34 #38628 /ChargingResistorsAllOFF: Diving into .. 12:29:34 #38628 /GetReadyTheDischarge: U_Bt: 900, Hrana: 98 12:29:34 #38628 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 12:29:34 #38628 /GetReadyTheDischarge: Charging ... HV=-11 V 12:29:35 #38628 /GetReadyTheDischarge: Charging ... HV=-11 V 12:29:35 #38628 /VacuumLog: Chamber: 22.10 mPa, 34.50 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 22.06 V 12:29:35 #38628 /GetReadyTheDischarge: Charging ... HV=-11 V 12:29:35 #38628 /GetReadyTheDischarge: Charging ... HV=13 V 12:29:36 #38628 /GetReadyTheDischarge: Charging ... HV=13 V 12:29:36 #38628 /GetReadyTheDischarge: Charging ... HV=61 V 12:29:37 #38628 /GetReadyTheDischarge: Charging ... HV=61 V 12:29:37 #38628 /GetReadyTheDischarge: Charging ... HV=61 V 12:29:38 #38628 /GetReadyTheDischarge: Charging ... HV=108 V 12:29:38 #38628 /GetReadyTheDischarge: Charging ... HV=108 V 12:29:39 #38628 /GetReadyTheDischarge: Charging ... HV=153 V 12:29:39 #38628 /VacuumLog: Chamber: 25.00 mPa, 34.50 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 22.77 V 12:29:39 #38628 /GetReadyTheDischarge: Charging ... HV=153 V 12:29:39 #38628 /GetReadyTheDischarge: Charging ... HV=198 V 12:29:40 #38628 /GetReadyTheDischarge: Charging ... HV=198 V 12:29:40 #38628 /GetReadyTheDischarge: Charging ... HV=198 V 12:29:41 #38628 /GetReadyTheDischarge: Charging ... HV=244 V 12:29:41 #38628 /GetReadyTheDischarge: Charging ... HV=244 V 12:29:42 #38628 /GetReadyTheDischarge: Charging ... HV=287 V 12:29:42 #38628 /GetReadyTheDischarge: Charging ... HV=287 V 12:29:42 #38628 /GetReadyTheDischarge: Charging ... HV=287 V , Gas: H2, GasValve: 22.77 V 12:29:43 #38628 /GetReadyTheDischarge: Charging ... HV=331 V 12:29:43 #38628 /GetReadyTheDischarge: Charging ... HV=331 V 12:29:44 #38628 /GetReadyTheDischarge: Charging ... HV=370 V 12:29:44 #38628 /GetReadyTheDischarge: Charging ... HV=370 V 12:29:45 #38628 /GetReadyTheDischarge: Charging ... HV=370 V 12:29:45 #38628 /GetReadyTheDischarge: Charging ... HV=408 V 12:29:46 #38628 /GetReadyTheDischarge: Charging ... HV=408 V 12:29:46 #38628 /GetReadyTheDischarge: Charging ... HV=447 V 12:29:46 #38628 /GetReadyTheDischarge: Charging ... HV=447 V 12:29:47 #38628 /GetReadyTheDischarge: Charging ... HV=447 V 12:29:47 #38628 /GetReadyTheDischarge: Charging ... HV=485 V 12:29:48 #38628 /GetReadyTheDischarge: Charging ... HV=485 V 12:29:48 #38628 /GetReadyTheDischarge: Charging ... HV=521 V 12:29:48 #38628 /GetReadyTheDischarge: Cd capacitor charging finished @ 521 V 12:29:49 #38628 /GetReadyTheDischarge: Charging ... HV=521 V 12:29:49 #38628 /GetReadyTheDischarge: Charging ... HV=557 V 12:29:50 #38628 /VacuumLog: Chamber: 24.60 mPa, 34.50 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 22.77 V 12:29:50 #38628 /GetReadyTheDischarge: Charging ... HV=557 V 12:29:50 #38628 /GetReadyTheDischarge: Charging ... HV=557 V 12:29:50 #38628 /GetReadyTheDischarge: Charging ... HV=594 V 12:29:51 #38628 /GetReadyTheDischarge: Charging ... HV=594 V 12:29:51 #38628 /GetReadyTheDischarge: Charging ... HV=629 V 12:29:52 #38628 /GetReadyTheDischarge: Charging ... HV=629 V 12:29:52 #38628 /GetReadyTheDischarge: Charging ... HV=629 V 12:29:52 #38628 /GetReadyTheDischarge: Charging ... HV=665 V 12:29:53 #38628 /GetReadyTheDischarge: Charging ... HV=665 V 12:29:53 #38628 /VacuumLog: Chamber: 24.40 mPa, 34.50 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 22.77 V 12:29:53 #38628 /GetReadyTheDischarge: Charging ... HV=665 V 12:29:54 #38628 /GetReadyTheDischarge: Charging ... HV=701 V 12:29:54 #38628 /GetReadyTheDischarge: Charging ... HV=701 V 12:29:55 #38628 /GetReadyTheDischarge: Charging ... HV=735 V 12:29:55 #38628 /GetReadyTheDischarge: Charging ... HV=735 V 12:29:55 #38628 /GetReadyTheDischarge: Charging ... HV=735 V 12:29:56 #38628 /GetReadyTheDischarge: Charging ... HV=766 V 12:29:56 #38628 /GetReadyTheDischarge: Charging ... HV=766 V 12:29:57 #38628 /GetReadyTheDischarge: Charging ... HV=798 V 12:29:57 #38628 /VacuumLog: Chamber: 24.30 mPa, 34.50 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 22.77 V 12:29:57 #38628 /GetReadyTheDischarge: Charging ... HV=798 V 12:29:58 #38628 /GetReadyTheDischarge: Charging ... HV=798 V 12:29:58 #38628 /GetReadyTheDischarge: Charging ... HV=829 V 12:29:58 #38628 /GetReadyTheDischarge: Charging ... HV=829 V 12:29:59 #38628 /GetReadyTheDischarge: Charging ... HV=858 V 12:29:59 #38628 /GetReadyTheDischarge: Charging ... HV=858 V 12:30:00 #38628 /GetReadyTheDischarge: Charging ... HV=858 V 12:30:00 #38628 /GetReadyTheDischarge: Charging ... HV=889 V 12:30:00 #38628 /GetReadyTheDischarge: Bt slow PowSup 12:30:00 #38628 /ChargingResistorsAllON: Diving into .. 12:30:01 #38628 /GetReadyTheDischarge: Charging ... HV=889 V , Gas: H2, GasValve: 22.77 V 12:30:01 #38628 /GetReadyTheDischarge: Charging ... HV=915 V 12:30:01 #38628 /ChargingResistorsAllON: Diving into .. 12:30:02 #38628 /GetReadyTheDischarge: Bt capacitor charging finished @ 915 V 12:30:02 #38628 /ChargingResistorsAllON: Diving into .. 12:30:02 #38628 /GetReadyTheDischarge: Ascending from .. 12:30:02 #38628 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 12:30:04 #38628 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:30:04 #38628 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:30:04 #38628 /VacuumLog: Chamber: 24.10 mPa, 34.50 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 22.77 V 12:30:06 #38628 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 12:30:08 #38628 /VacuumLog: Chamber: 24.00 mPa, 34.50 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 22.77 V 12:30:11 #38628 /VacuumLog: Chamber: 24.00 mPa, 34.50 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 22.77 V 12:30:15 #38628 /VacuumLog: Chamber: 24.00 mPa, 34.50 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 22.77 V 12:30:17 #38628 /Trigger: Going through .. 12:30:17 #38628 Discharge/HWTrigger: Going through .. 12:30:17 #38628 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 12:30:17 #38628 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 200 12:30:17 #38628 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4800 12:30:19 #38628 /VacuumLog: Chamber: 23.90 mPa, 34.50 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 22.77 V 12:30:21 #38628 /ChargingResistorsAllON: Diving into .. 12:30:22 #38628 /VacuumLog: Chamber: 24.30 mPa, 34.50 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 0.00 V 12:30:24 #38628 /SecurePostDischargeState: Going through .. 12:30:24 #38628 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 12:30:26 #38628 /VacuumLog: Chamber: 1.41 mPa, 34.50 C, ForVacuum: 2.15 Pa, Gas: NULL, GasValve: 0.00 V 12:30:29 #38628 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 12:30:30 #38628 /VacuumLog: Chamber: 1.28 mPa, 34.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 12:30:33 #38628 /VacuumLog: Chamber: 1.20 mPa, 34.50 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 12:30:37 #38628 /VacuumLog: Chamber: 1.15 mPa, 34.50 C, ForVacuum: 0.86 Pa, Gas: NULL, GasValve: 0.00 V 12:30:41 #38628 /VacuumLog: Chamber: 1.11 mPa, 34.50 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 12:30:44 #38628 /VacuumLog: Chamber: 1.08 mPa, 34.50 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 12:30:48 #38628 /VacuumLog: Chamber: 1.05 mPa, 34.50 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 12:30:48 #38628 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 12:30:52 #38628 /VacuumLog: Chamber: 1.03 mPa, 34.50 C, ForVacuum: 0.875 Pa, Gas: NULL, GasValve: 0.00 V 12:30:55 #38628 /VacuumLog: Chamber: 1.01 mPa, 34.50 C, ForVacuum: 0.875 Pa, Gas: NULL, GasValve: 0.00 V 12:30:59 #38628 /VacuumLog: Chamber: 0.99 mPa, 34.50 C, ForVacuum: 0.875 Pa, Gas: NULL, GasValve: 0.00 V 12:31:02 #38628 /VacuumLog: Chamber: 0.98 mPa, 34.40 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:06 #38628 /VacuumLog: Chamber: 0.97 mPa, 34.40 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:10 #38628 /VacuumLog: Chamber: 0.96 mPa, 34.50 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:13 #38628 /VacuumLog: Chamber: 0.95 mPa, 34.40 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:17 #38628 /VacuumLog: Chamber: 0.94 mPa, 34.40 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:21 #38628 /VacuumLog: Chamber: 0.94 mPa, 34.40 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:23 #38628 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 12:31:24 #38628 /VacuumLog: Chamber: 0.93 mPa, 34.50 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:28 #38628 /VacuumLog: Chamber: 0.93 mPa, 34.50 C, ForVacuum: 0.88 Pa, Gas: NULL, GasValve: 0.00 V 12:31:30 #38628 /DischargeFunction: General Calling FinalDischargeOperations