11:16:17 #38702 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 11:16:17 #38702 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:16:19 #38702 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:16:19 #38702 /GetReadyTheDischarge: Going with gas pressure 16 11:16:19 #38702 /GetReadyTheDischarge: Going with gas type H 11:16:19 #38702 /GetReadyTheDischarge: Discharge with Hydrogen request 11:16:19 #38702 /GetReadyTheDischarge: Discharge with 16 mPa request 11:16:19 #38702 /VacuumLog: Chamber: 0.98 mPa, 37.60 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 0.00 V h Bt_orientation CW 11:16:19 #38702 /GetReadyTheDischarge: Discharge with Bt CW request 11:16:19 #38702 /GetReadyTheDischarge: Going with CD_orientation CW 11:16:19 #38702 /GetReadyTheDischarge: Discharge with CD CW request 11:16:23 #38702 /VacuumLog: Chamber: 1.96 mPa, 37.60 C, ForVacuum: 1.05 Pa, Gas: H2, GasValve: 23.67 V 11:16:26 #38702 /VacuumLog: Chamber: 30.20 mPa, 37.60 C, ForVacuum: 2.8 Pa, Gas: H2, GasValve: 24.24 V 11:16:26 #38702 /GetReadyTheDischarge: Bt capacitor charging started 11:16:30 #38702 /VacuumLog: Chamber: 11.00 mPa, 37.60 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 22.10 V 11:16:31 #38702 /GetReadyTheDischarge: Cd capacitor charging started 11:16:31 #38702 /ChargingResistorsAllOFF: Diving into .. 11:16:31 #38702 /GetReadyTheDischarge: U_Bt: 600, Hrana: 98 11:16:31 #38702 /GetReadyTheDischarge: U_Et: 400, Hrana: 98 11:16:31 #38702 /GetReadyTheDischarge: Charging ... HV=-12 V 11:16:31 #38702 /GetReadyTheDischarge: Charging ... HV=-12 V 11:16:32 #38702 /GetReadyTheDischarge: Charging ... HV=-12 V 11:16:32 #38702 /GetReadyTheDischarge: Charging ... HV=18 V 11:16:33 #38702 /GetReadyTheDischarge: Charging ... HV=18 V 11:16:33 #38702 /GetReadyTheDischarge: Charging ... HV=66 V 11:16:34 #38702 /GetReadyTheDischarge: Charging ... HV=66 V 11:16:34 #38702 /GetReadyTheDischarge: Charging ... HV=66 V 11:16:35 #38702 /GetReadyTheDischarge: Charging ... HV=113 V 11:16:35 #38702 /GetReadyTheDischarge: Charging ... HV=113 V 11:16:35 #38702 /GetReadyTheDischarge: Charging ... HV=159 V 11:16:36 #38702 /GetReadyTheDischarge: Charging ... HV=159 V 11:16:36 #38702 /GetReadyTheDischarge: Charging ... HV=159 V 11:16:37 #38702 /GetReadyTheDischarge: Charging ... HV=204 V 11:16:37 #38702 /GetReadyTheDischarge: Charging ... HV=204 V 11:16:38 #38702 /GetReadyTheDischarge: Charging ... HV=249 V 11:16:38 #38702 /GetReadyTheDischarge: Charging ... HV=249 V 11:16:38 #38702 /GetReadyTheDischarge: Charging ... HV=249 V 11:16:39 #38702 /GetReadyTheDischarge: Charging ... HV=293 V 11:16:39 #38702 /GetReadyTheDischarge: Charging ... HV=293 V 11:16:40 #38702 /GetReadyTheDischarge: Charging ... HV=336 V 11:16:40 #38702 /GetReadyTheDischarge: Charging ... HV=336 V 11:16:41 #38702 /GetReadyTheDischarge: Charging ... HV=336 V 11:16:41 #38702 /VacuumLog: Chamber: 16.30 mPa, 37.50 C, ForVacuum: 4.25 Pa, Gas: H2, GasValve: 23.26 V 11:16:41 #38702 /GetReadyTheDischarge: Charging ... HV=375 V 11:16:42 #38702 /GetReadyTheDischarge: Charging ... HV=375 V 11:16:42 #38702 /GetReadyTheDischarge: Charging ... HV=413 V 11:16:42 #38702 /GetReadyTheDischarge: Cd capacitor charging finished @ 413 V 11:16:43 #38702 /GetReadyTheDischarge: Charging ... HV=413 V 11:16:43 #38702 /GetReadyTheDischarge: Charging ... HV=453 V 11:16:43 #38702 /GetReadyTheDischarge: Charging ... HV=453 V 11:16:44 #38702 /GetReadyTheDischarge: Charging ... HV=453 V 11:16:44 #38702 /GetReadyTheDischarge: Charging ... HV=493 V 11:16:45 #38702 /VacuumLog: Chamber: 16.10 mPa, 37.50 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 23.26 V 11:16:45 #38702 /GetReadyTheDischarge: Charging ... HV=493 V 11:16:45 #38702 /GetReadyTheDischarge: Charging ... HV=532 V 11:16:45 #38702 /GetReadyTheDischarge: Charging ... HV=532 V 11:16:46 #38702 /GetReadyTheDischarge: Charging ... HV=532 V 11:16:46 #38702 /GetReadyTheDischarge: Charging ... HV=17 V 11:16:47 #38702 /GetReadyTheDischarge: Charging ... HV=571 V 11:16:47 #38702 /GetReadyTheDischarge: Charging ... HV=607 V 11:16:47 #38702 /ChargingResistorsAllON: Diving into .. 11:16:48 #38702 /GetReadyTheDischarge: Bt capacitor charging finished @ 607 V 11:16:48 #38702 /ChargingResistorsAllON: Diving into .. 11:16:48 #38702 /VacuumLog: Chamber: 16.00 mPa, 37.50 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 23.26 V 11:16:48 #38702 /GetReadyTheDischarge: Ascending from .. 11:16:48 #38702 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:16:50 #38702 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:16:50 #38702 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:16:52 #38702 /VacuumLog: Chamber: 15.90 mPa, 37.60 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 23.26 V 11:16:52 #38702 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:16:55 #38702 /VacuumLog: Chamber: 15.90 mPa, 37.50 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 23.26 V 11:16:59 #38702 /VacuumLog: Chamber: 15.80 mPa, 37.50 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 23.26 V 11:17:03 #38702 /VacuumLog: Chamber: 15.80 mPa, 37.50 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 23.26 V 11:17:03 #38702 /Trigger: Going through .. 11:17:03 #38702 Discharge/HWTrigger: Going through .. 11:17:03 #38702 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 11:17:03 #38702 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 11:17:03 #38702 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 11:17:07 #38702 /VacuumLog: Chamber: 14.70 mPa, 37.50 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 23.26 V 11:17:07 #38702 /ChargingResistorsAllON: Diving into .. 11:17:10 #38702 /SecurePostDischargeState: Going through .. 11:17:10 #38702 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:17:10 #38702 /VacuumLog: Chamber: 1.96 mPa, 37.50 C, ForVacuum: 3.3 Pa, Gas: NULL, GasValve: 0.00 V 11:17:14 #38702 /VacuumLog: Chamber: 1.17 mPa, 37.40 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 11:17:15 #38702 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:17:17 #38702 /VacuumLog: Chamber: 1.10 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:21 #38702 /VacuumLog: Chamber: 1.06 mPa, 37.40 C, ForVacuum: 0.99 Pa, Gas: NULL, GasValve: 0.00 V 11:17:25 #38702 /VacuumLog: Chamber: 1.03 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:28 #38702 /VacuumLog: Chamber: 1.02 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:32 #38702 /VacuumLog: Chamber: 1.01 mPa, 37.40 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:34 #38702 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:17:36 #38702 /VacuumLog: Chamber: 1.00 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:39 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.40 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:43 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.40 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:46 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:50 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:54 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.40 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:17:57 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:18:01 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:18:05 #38702 /VacuumLog: Chamber: 0.98 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:18:07 #38702 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 11:18:08 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:18:12 #38702 /VacuumLog: Chamber: 0.99 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 11:18:13 #38702 /DischargeFunction: General Calling FinalDischargeOperations