16:50:36 #38751 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 16:50:36 #38751 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:50:37 #38751 /VacuumLog: Chamber: 0.90 mPa, 41.70 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 16:50:38 #38751 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:50:38 #38751 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 16:50:38 #38751 /GetReadyTheDischarge: Going with gas pressure 10 16:50:38 #38751 /GetReadyTheDischarge: Going with gas type H 16:50:38 16:50:38 #38751 /GetReadyTheDischarge: Discharge with Hydrogen request 16:50:38 #3816:50:39 #38751 /GetReadyTheDischarge: Discharge with 10 mPa request 16:50:39 #38751 /GetReadyTheDischarge: Going with CD_orientation CW 16:50:39 #38751 /GetReadyTheDischarge: Discharge with CD CW request 16:50:41 #38751 /VacuumLog: Chamber: 0.90 mPa, 41.70 C, ForVacuum: 0.95 Pa, Gas: H2, GasValve: 21.14 V 16:50:44 #38751 /VacuumLog: Chamber: 0.90 mPa, 41.70 C, ForVacuum: 0.95 Pa, Gas: H2, GasValve: 22.96 V 16:50:46 #38751 /GetReadyTheDischarge: Bt capacitor charging started 16:50:48 #38751 /VacuumLog: Chamber: 2.30 mPa, 41.70 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 25.57 V 16:50:50 #38751 /GetReadyTheDischarge: Cd capacitor charging started 16:50:50 #38751 /ChargingResistorsAllOFF: Diving into .. 16:50:50 #38751 /GetReadyTheDischarge: U_Bt: 220, Hrana: 98 16:50:50 #38751 /GetReadyTheDischarge: U_Et: 220, Hrana: 98 16:50:51 #38751 /GetReadyTheDischarge: Charging ... HV=-12 V 16:50:51 #38751 /GetReadyTheDischarge: Charging ... HV=-12 V 16:50:51 #38751 /GetReadyTheDischarge: Charging ... HV=3 V 16:50:52 #38751 /GetReadyTheDischarge: Charging ... HV=3 V 16:50:52 #38751 /GetReadyTheDischarge: Charging ... HV=49 V 16:50:53 #38751 /GetReadyTheDischarge: Charging ... HV=49 V 16:50:53 #38751 /GetReadyTheDischarge: Charging ... HV=49 V 16:50:54 #38751 /GetReadyTheDischarge: Charging ... HV=98 V 16:50:54 #38751 /GetReadyTheDischarge: Charging ... HV=98 V 16:50:54 #38751 /GetReadyTheDischarge: Charging ... HV=144 V 16:50:55 #38751 /GetReadyTheDischarge: Charging ... HV=144 V 16:50:55 #38751 /GetReadyTheDischarge: Charging ... HV=144 V 16:50:56 #38751 /GetReadyTheDischarge: Charging ... HV=190 V 16:50:56 #38751 /GetReadyTheDischarge: Charging ... HV=190 V 16:50:57 #38751 /GetReadyTheDischarge: Charging ... HV=237 V 16:50:57 #38751 /GetReadyTheDischarge: Bt capacitor charging finished @ 237 V 16:50:57 #38751 /ChargingResistorsAllON: Diving into .. 16:50:57 #38751 /GetReadyTheDischarge: Cd capacitor charging finished @ 237 V 16:50:58 #38751 /ChargingResistorsAllON: Diving into .. 16:50:58 #38751 /GetReadyTheDischarge: Ascending from .. 16:50:58 #38751 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:50:59 #38751 /VacuumLog: Chamber: 14.10 mPa, 41.70 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 23.74 V 16:51:00 #38751 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:51:00 #38751 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:51:02 #38751 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:51:03 #38751 /VacuumLog: Chamber: 14.20 mPa, 41.70 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 23.74 V 16:51:06 #38751 /VacuumLog: Chamber: 14.30 mPa, 41.70 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 23.74 V 16:51:10 #38751 /VacuumLog: Chamber: 14.20 mPa, 41.70 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 23.74 V 16:51:12 #38751 /Trigger: Going through .. 16:51:12 #38751 Discharge/HWTrigger: Going through .. 16:51:13 #38751 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 16:51:13 #38751 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 16:51:13 #38751 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 16:51:14 #38751 /VacuumLog: Chamber: 14.20 mPa, 41.70 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 23.74 V 16:51:17 #38751 /VacuumLog: Chamber: 14.20 mPa, 41.70 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 23.74 V 16:51:18 #38751 /ChargingResistorsAllON: Diving into .. 16:51:21 #38751 /SecurePostDischargeState: Going through .. 16:51:21 #38751 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:51:21 #38751 /VacuumLog: Chamber: 1.47 mPa, 41.70 C, ForVacuum: 3.05 Pa, Gas: NULL, GasValve: 0.00 V 16:51:25 #38751 /VacuumLog: Chamber: 0.92 mPa, 41.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:51:26 #38751 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:51:28 #38751 /VacuumLog: Chamber: 0.89 mPa, 41.70 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 16:51:32 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 16:51:36 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.60 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 16:51:39 #38751 /VacuumLog: Chamber: 0.87 mPa, 41.60 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 16:51:43 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.70 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 16:51:43 #38751 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:51:46 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.60 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 16:51:50 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.70 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 16:51:54 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.60 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 16:51:57 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.70 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 16:52:01 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.60 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 16:52:05 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.60 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 16:52:08 #38751 /VacuumLog: Chamber: 0.88 mPa, 41.60 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 16:52:12 #38751 /VacuumLog: Chamber: 0.89 mPa, 41.60 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 16:52:16 #38751 /VacuumLog: Chamber: 0.89 mPa, 41.60 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 16:52:19 #38751 /VacuumLog: Chamber: 0.89 mPa, 41.60 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 16:52:22 #38751 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:52:23 #38751 /VacuumLog: Chamber: 0.89 mPa, 41.60 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 16:52:25 #38751 /DischargeFunction: General Calling FinalDischargeOperations