16:01:28 #38792 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 16:01:28 #38792 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:01:30 #38792 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:01:30 #38792 /GetReadyTheDischarge: Going with gas pressure 10 16:01:30 #38792 /GetReadyTheDischarge: Going with gas type H 16:01:30 #38792 /GetReadyTheDischarge: Discharge with Hydrogen request 16:01:30 #38792 /GetReadyTheDischarge: Discharge with 10 mPa request 01:30 #38792 /GetReadyTheDischarge: Going with Bt_orientation CW 16:01:30 #38792 /GetReadyTheDischarge: Discharge with Bt CW request 16:01:30 #38792 /GetReadyTheDischarge: Going with CD_orientation CW 16:01:31 #38792 /GetReadyTheDischarge: Discharge with CD CW request 16:01:31 #38792 /VacuumLog: Chamber: 0.82 mPa, 36.20 C, ForVacuum: 0.875 Pa, Gas: H2, GasValve: 21.15 V 16:01:35 #38792 /VacuumLog: Chamber: 1.65 mPa, 36.20 C, ForVacuum: 0.925 Pa, Gas: H2, GasValve: 22.91 V 16:01:37 #38792 /GetReadyTheDischarge: Bt capacitor charging started 16:01:38 #38792 /VacuumLog: Chamber: 6.26 mPa, 36.10 C, ForVacuum: 1.6 Pa, Gas: H2, GasValve: 24.01 V 16:01:42 #38792 /GetReadyTheDischarge: Cd capacitor charging started 16:01:42 #38792 /ChargingResistorsAllOFF: Diving into .. 16:01:42 #38792 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 16:01:42 #38792 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 16:01:42 #38792 /GetReadyTheDischarge: Charging ... HV=-13 V 16:01:43 #38792 /GetReadyTheDischarge: Charging ... HV=-13 V 16:01:43 #38792 /GetReadyTheDischarge: Charging ... HV=2 V 16:01:43 #38792 /GetReadyTheDischarge: Charging ... HV=2 V 16:01:44 #38792 /GetReadyTheDischarge: Charging ... HV=2 V 16:01:44 #38792 /GetReadyTheDischarge: Charging ... HV=49 V 16:01:45 #38792 /GetReadyTheDischarge: Charging ... HV=49 V 16:01:45 #38792 /GetReadyTheDischarge: Charging ... HV=97 V 16:01:46 #38792 /VacuumLog: Chamber: 10.50 mPa, 36.20 C, ForVacuum: 3.35 Pa, Gas: H2, GasValve: 23.34 V 16:01:46 #38792 /GetReadyTheDischarge: Charging ... HV=97 V 16:01:46 #38792 /GetReadyTheDischarge: Charging ... HV=143 V 16:01:47 #38792 /GetReadyTheDischarge: Charging ... HV=143 V 16:01:47 #38792 /GetReadyTheDischarge: Charging ... HV=143 V 16:01:47 #38792 /GetReadyTheDischarge: Charging ... HV=189 V 16:01:48 #38792 /GetReadyTheDischarge: Charging ... HV=189 V 16:01:48 #38792 /GetReadyTheDischarge: Charging ... HV=235 V 16:01:49 #38792 /GetReadyTheDischarge: Charging ... HV=235 V 16:01:49 #38792 /GetReadyTheDischarge: Charging ... HV=235 V 16:01:49 #38792 /VacuumLog: Chamber: 10.10 mPa, 36.20 C, ForVacuum: 3.25 Pa, Gas: H2, GasValve: 23.34 V 16:01:50 #38792 /GetReadyTheDischarge: Charging ... HV=279 V 16:01:50 #38792 /GetReadyTheDischarge: Charging ... HV=279 V 16:01:50 #38792 /GetReadyTheDischarge: Charging ... HV=323 V 16:01:51 #38792 /GetReadyTheDischarge: Charging ... HV=323 V 16:01:51 #38792 /GetReadyTheDischarge: Charging ... HV=323 V 16:01:52 #38792 /GetReadyTheDischarge: Charging ... HV=363 V 16:01:52 #38792 /GetReadyTheDischarge: Charging ... HV=363 V 16:01:53 #38792 /GetReadyTheDischarge: Charging ... HV=402 V 16:01:53 #38792 /GetReadyTheDischarge: Charging ... HV=402 V Gas: H2, GasValve: 23.34 V 16:01:54 #38792 /GetReadyTheDischarge: Charging ... HV=402 V 16:01:54 #38792 /GetReadyTheDischarge: Charging ... HV=441 V 16:01:54 #38792 /GetReadyTheDischarge: Charging ... HV=441 V 16:01:55 #38792 /GetReadyTheDischarge: Charging ... HV=22 V 16:01:55 #38792 /GetReadyTheDischarge: Charging ... HV=480 V 16:01:56 #38792 /GetReadyTheDischarge: Cd capacitor charging finished @ 480 V 16:01:56 #38792 /GetReadyTheDischarge: Charging ... HV=515 V 16:01:56 #38792 /GetReadyTheDischarge: Charging ... HV=515 V 16:01:57 #38792 /GetReadyTheDischarge: Charging ... HV=515 V 16:01:57 #38792 /GetReadyTheDischarge: Charging ... HV=553 V 16:01:58 #38792 /GetReadyTheDischarge: Charging ... HV=553 V 16:01:58 #38792 /GetReadyTheDischarge: Charging ... HV=591 V 16:01:58 #38792 /GetReadyTheDischarge: Charging ... HV=591 V 16:01:59 #38792 /GetReadyTheDischarge: Charging ... HV=591 V 16:01:59 #38792 /GetReadyTheDischarge: Charging ... HV=627 V 16:02:00 #38792 /GetReadyTheDischarge: Charging ... HV=627 V 16:02:00 #38792 /GetReadyTheDischarge: Charging ... HV=663 V 16:02:01 #38792 /GetReadyTheDischarge: Charging ... HV=663 V 16:02:01 #38792 /GetReadyTheDischarge: Charging ... HV=663 V 16:02:01 #38792 /GetReadyTheDischarge: Charging ... HV=699 V 16:02:02 #38792 /GetReadyTheDischarge: Charging ... HV=699 V 16:02:02 #38792 /GetReadyTheDischarge: Charging ... HV=733 V 16:02:03 #38792 /GetReadyTheDischarge: Charging ... HV=733 V 16:02:03 #38792 /GetReadyTheDischarge: Charging ... HV=733 V 16:02:03 #38792 /GetReadyTheDischarge: Charging ... HV=764 V 16:02:04 #38792 /GetReadyTheDischarge: Charging ... HV=764 V 16:02:04 #38792 /GetReadyTheDischarge: Charging ... HV=796 V 16:02:04 #38792 /GetReadyTheDischarge: Bt slow PowSup 16:02:04 #38792 /ChargingResistorsAllON: Diving into .. 16:02:05 #38792 /GetReadyTheDischarge: Charging ... HV=22 V 16:02:05 #38792 /GetReadyTheDischarge: Bt boost PowSup 16:02:05 #38792 /ChargingResistorsAllOFF: Diving into .. 16:02:05 #38792 /GetReadyTheDischarge: Charging ... HV=822 V 16:02:06 #38792 /ChargingResistorsAllON: Diving into .. 16:02:06 #38792 /GetReadyTheDischarge: Bt capacitor charging finished @ 822 V 16:02:06 #38792 /ChargingResistorsAllON: Diving into .. 16:02:07 #38792 /GetReadyTheDischarge: Ascending from .. 16:02:07 #38792 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:02:08 #38792 /VacuumLog: Chamber: 9.95 mPa, 36.30 C, ForVacuum: 3.15 Pa, Gas: H2, GasValve: 23.34 V 16:02:08 #38792 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:02:08 #38792 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:02:10 #38792 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:02:11 #38792 /VacuumLog: Chamber: 9.95 mPa, 36.30 C, ForVacuum: 3.1 Pa, Gas: H2, GasValve: 23.34 V 16:02:15 #38792 /VacuumLog: Chamber: 9.95 mPa, 36.30 C, ForVacuum: 3.1 Pa, Gas: H2, GasValve: 23.34 V 16:02:18 #38792 /VacuumLog: Chamber: 9.94 mPa, 36.30 C, ForVacuum: 3.1 Pa, Gas: H2, GasValve: 23.34 V 16:02:21 #38792 /Trigger: Going through .. 16:02:21 #38792 Discharge/HWTrigger: Going through .. 16:02:21 #38792 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 16:02:21 #38792 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 16:02:21 #38792 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 16:02:22 #38792 /VacuumLog: Chamber: 9.93 mPa, 36.30 C, ForVacuum: 3.15 Pa, Gas: H2, GasValve: 23.34 V 16:02:25 #38792 /ChargingResistorsAllON: Diving into .. 16:02:26 #38792 /VacuumLog: Chamber: 10.30 mPa, 36.30 C, ForVacuum: 2.95 Pa, Gas: H2, GasValve: 23.34 V 16:02:28 #38792 /SecurePostDischargeState: Going through .. 16:02:28 #38792 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:02:29 #38792 /VacuumLog: Chamber: 1.13 mPa, 36.30 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 16:02:33 #38792 /VacuumLog: Chamber: 0.97 mPa, 36.30 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:02:33 #38792 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:02:37 #38792 /VacuumLog: Chamber: 0.93 mPa, 36.30 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:02:40 #38792 /VacuumLog: Chamber: 0.90 mPa, 36.30 C, ForVacuum: 0.85 Pa, Gas: NULL, GasValve: 0.00 V 16:02:44 #38792 /VacuumLog: Chamber: 0.88 mPa, 36.40 C, ForVacuum: 0.855 Pa, Gas: NULL, GasValve: 0.00 V 16:02:48 #38792 /VacuumLog: Chamber: 0.87 mPa, 36.40 C, ForVacuum: 0.855 Pa, Gas: NULL, GasValve: 0.00 V 16:02:51 #38792 /VacuumLog: Chamber: 0.86 mPa, 36.40 C, ForVacuum: 0.86 Pa, Gas: NULL, GasValve: 0.00 V 16:02:53 #38792 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:02:55 #38792 /VacuumLog: Chamber: 0.85 mPa, 36.40 C, ForVacuum: 0.86 Pa, Gas: NULL, GasValve: 0.00 V 16:02:59 #38792 /VacuumLog: Chamber: 0.85 mPa, 36.30 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:03:02 #38792 /VacuumLog: Chamber: 0.84 mPa, 36.30 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:03:06 #38792 /VacuumLog: Chamber: 0.84 mPa, 36.30 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:03:10 #38792 /VacuumLog: Chamber: 0.84 mPa, 36.40 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:03:13 #38792 /VacuumLog: Chamber: 0.83 mPa, 36.30 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:03:17 #38792 /VacuumLog: Chamber: 0.83 mPa, 36.40 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:03:21 #38792 /VacuumLog: Chamber: 0.83 mPa, 36.30 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:03:24 #38792 /VacuumLog: Chamber: 0.83 mPa, 36.30 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:03:27 #38792 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:03:28 #38792 /VacuumLog: Chamber: 0.83 mPa, 36.40 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:03:32 #38792 /VacuumLog: Chamber: 0.83 mPa, 36.40 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:03:33 #38792 /DischargeFunction: General Calling FinalDischargeOperations