16:07:32 #38793 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 16:07:32 #38793 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:07:33 #38793 /VacuumLog: Chamber: 0.83 mPa, 36.20 C, ForVacuum: 0.875 Pa, Gas: NULL, GasValve: 0.00 V 16:07:34 #38793 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:07:34 #38793 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 16:07:34 #38793 /GetReadyTheDischarge: Going with gas pressure 10 16:07:34 #38793 /GetReadyTheDischarge: Diving into .. 16:07:34 16:07:34 #38793 /GetReadyTheDischarge: Discharge with Hydrogen request 16:07:34 #3816:07:34 #38793 /GetReadyTheDischarge: Discharge with 10 mPa request 16:07:35 #38793 /GetReadyTheDischarge: Going with CD_orientation CW 16:07:35 #38793 /GetReadyTheDischarge: Discharge with CD CW request 16:07:36 #38793 /VacuumLog: Chamber: 0.84 mPa, 36.20 C, ForVacuum: 0.875 Pa, Gas: H2, GasValve: 21.15 V 16:07:40 #38793 /VacuumLog: Chamber: 2.18 mPa, 36.10 C, ForVacuum: 0.97 Pa, Gas: H2, GasValve: 23.66 V 16:07:42 #38793 /GetReadyTheDischarge: Bt capacitor charging started 16:07:43 #38793 /VacuumLog: Chamber: 6.82 mPa, 36.10 C, ForVacuum: 1.75 Pa, Gas: H2, GasValve: 24.40 V 16:07:46 #38793 /GetReadyTheDischarge: Cd capacitor charging started 16:07:46 #38793 /ChargingResistorsAllOFF: Diving into .. 16:07:46 #38793 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 16:07:46 #38793 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 16:07:46 #38793 /GetReadyTheDischarge: Charging ... HV=-13 V 16:07:47 #38793 /GetReadyTheDischarge: Charging ... HV=-13 V 16:07:47 #38793 /VacuumLog: Chamber: 13.60 mPa, 36.20 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 24.31 V 16:07:47 #38793 /GetReadyTheDischarge: Charging ... HV=-1 V 16:07:48 #38793 /GetReadyTheDischarge: Charging ... HV=-1 V 16:07:48 #38793 /GetReadyTheDischarge: Charging ... HV=43 V 16:07:48 #38793 /GetReadyTheDischarge: Charging ... HV=43 V 16:07:49 #38793 /GetReadyTheDischarge: Charging ... HV=43 V 16:07:49 #38793 /GetReadyTheDischarge: Charging ... HV=92 V 16:07:50 #38793 /GetReadyTheDischarge: Charging ... HV=92 V 16:07:50 #38793 /GetReadyTheDischarge: Charging ... HV=138 V 16:07:51 #38793 /GetReadyTheDischarge: Charging ... HV=138 V 16:07:51 #38793 /VacuumLog: Chamber: 10.90 mPa, 36.10 C, ForVacuum: 3.45 Pa, Gas: H2, GasValve: 23.49 V 16:07:51 #38793 /GetReadyTheDischarge: Charging ... HV=138 V 16:07:52 #38793 /GetReadyTheDischarge: Charging ... HV=183 V 16:07:52 #38793 /GetReadyTheDischarge: Charging ... HV=183 V 16:07:52 #38793 /GetReadyTheDischarge: Charging ... HV=230 V 16:07:53 #38793 /GetReadyTheDischarge: Charging ... HV=230 V 16:07:53 #38793 /GetReadyTheDischarge: Charging ... HV=274 V 16:07:54 #38793 /GetReadyTheDischarge: Charging ... HV=274 V 16:07:54 #38793 /GetReadyTheDischarge: Charging ... HV=274 V 16:07:55 #38793 /GetReadyTheDischarge: Charging ... HV=319 V Gas: H2, GasValve: 23.49 V 16:07:55 #38793 /GetReadyTheDischarge: Charging ... HV=319 V 16:07:55 #38793 /GetReadyTheDischarge: Charging ... HV=359 V 16:07:56 #38793 /GetReadyTheDischarge: Charging ... HV=22 V 16:07:56 #38793 /GetReadyTheDischarge: Charging ... HV=359 V 16:07:57 #38793 /GetReadyTheDischarge: Charging ... HV=398 V 16:07:57 #38793 /GetReadyTheDischarge: Charging ... HV=398 V 16:07:58 #38793 /GetReadyTheDischarge: Charging ... HV=437 V 16:07:58 #38793 /GetReadyTheDischarge: Charging ... HV=437 V 16:07:59 #38793 /GetReadyTheDischarge: Charging ... HV=437 V 16:07:59 #38793 /GetReadyTheDischarge: Charging ... HV=476 V 16:07:59 #38793 /GetReadyTheDischarge: Cd capacitor charging finished @ 476 V 16:08:00 #38793 /GetReadyTheDischarge: Charging ... HV=476 V 16:08:00 #38793 /GetReadyTheDischarge: Charging ... HV=512 V 16:08:00 #38793 /GetReadyTheDischarge: Charging ... HV=512 V 16:08:01 #38793 /GetReadyTheDischarge: Charging ... HV=551 V 16:08:01 #38793 /GetReadyTheDischarge: Charging ... HV=551 V 16:08:02 #38793 /VacuumLog: Chamber: 10.40 mPa, 36.10 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.49 V 16:08:02 #38793 /GetReadyTheDischarge: Charging ... HV=551 V 16:08:02 #38793 /GetReadyTheDischarge: Charging ... HV=589 V 16:08:03 #38793 /GetReadyTheDischarge: Charging ... HV=589 V 16:08:03 #38793 /GetReadyTheDischarge: Charging ... HV=589 V 16:08:03 #38793 /GetReadyTheDischarge: Charging ... HV=624 V 16:08:04 #38793 /GetReadyTheDischarge: Charging ... HV=624 V 16:08:04 #38793 /GetReadyTheDischarge: Charging ... HV=660 V 16:08:05 #38793 /GetReadyTheDischarge: Charging ... HV=660 V 16:08:05 #38793 /GetReadyTheDischarge: Charging ... HV=660 V 16:08:05 #38793 /VacuumLog: Chamber: 10.40 mPa, 36.10 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.49 V 16:08:05 #38793 /GetReadyTheDischarge: Charging ... HV=697 V 16:08:06 #38793 /GetReadyTheDischarge: Charging ... HV=697 V 16:08:06 #38793 /GetReadyTheDischarge: Charging ... HV=730 V 16:08:07 #38793 /GetReadyTheDischarge: Charging ... HV=730 V 16:08:07 #38793 /GetReadyTheDischarge: Charging ... HV=730 V 16:08:08 #38793 /GetReadyTheDischarge: Charging ... HV=762 V 16:08:08 #38793 /GetReadyTheDischarge: Charging ... HV=762 V 16:08:08 #38793 /GetReadyTheDischarge: Charging ... HV=794 V 16:08:09 #38793 /GetReadyTheDischarge: Bt slow PowSup 16:08:09 #38793 /ChargingResistorsAllON: Diving into .. 16:08:09 #38793 /VacuumLog: Chamber: 10.30 mPa, 36.20 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.49 V 16:08:09 #38793 /GetReadyTheDischarge: Charging ... HV=794 V 16:08:09 #38793 /GetReadyTheDischarge: Charging ... HV=22 V 16:08:09 #38793 /GetReadyTheDischarge: Bt boost PowSup 16:08:10 #38793 /ChargingResistorsAllOFF: Diving into .. 16:08:10 #38793 /GetReadyTheDischarge: Charging ... HV=821 V 16:08:10 #38793 /ChargingResistorsAllON: Diving into .. 16:08:11 #38793 /GetReadyTheDischarge: Bt capacitor charging finished @ 821 V 16:08:11 #38793 /ChargingResistorsAllON: Diving into .. 16:08:11 #38793 /GetReadyTheDischarge: Ascending from .. 16:08:11 #38793 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:08:12 #38793 /VacuumLog: Chamber: 10.30 mPa, 36.20 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.49 V 16:08:13 #38793 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:08:13 #38793 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:08:15 #38793 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:08:16 #38793 /VacuumLog: Chamber: 10.20 mPa, 36.10 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.49 V 16:08:20 #38793 /VacuumLog: Chamber: 10.20 mPa, 36.20 C, ForVacuum: 3.15 Pa, Gas: H2, GasValve: 23.49 V 16:08:23 #38793 /VacuumLog: Chamber: 10.20 mPa, 36.20 C, ForVacuum: 3.15 Pa, Gas: H2, GasValve: 23.49 V 16:08:26 #38793 /Trigger: Going through .. 16:08:26 #38793 Discharge/HWTrigger: Going through .. 16:08:26 #38793 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 16:08:26 #38793 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 16:08:26 #38793 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 16:08:27 #38793 /VacuumLog: Chamber: 10.20 mPa, 36.20 C, ForVacuum: 3.15 Pa, Gas: H2, GasValve: 23.49 V 16:08:30 #38793 /ChargingResistorsAllON: Diving into .. 16:08:31 #38793 /VacuumLog: Chamber: 10.40 mPa, 36.20 C, ForVacuum: 3.0 Pa, Gas: H2, GasValve: 0.00 V 16:08:33 #38793 /SecurePostDischargeState: Going through .. 16:08:33 #38793 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:08:34 #38793 /VacuumLog: Chamber: 1.04 mPa, 36.20 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 16:08:38 #38793 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:08:38 #38793 /VacuumLog: Chamber: 0.94 mPa, 36.20 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V 16:08:41 #38793 /VacuumLog: Chamber: 0.90 mPa, 36.20 C, ForVacuum: 0.86 Pa, Gas: NULL, GasValve: 0.00 V 16:08:45 #38793 /VacuumLog: Chamber: 0.88 mPa, 36.20 C, ForVacuum: 0.845 Pa, Gas: NULL, GasValve: 0.00 V 16:08:49 #38793 /VacuumLog: Chamber: 0.86 mPa, 36.10 C, ForVacuum: 0.85 Pa, Gas: NULL, GasValve: 0.00 V 16:08:52 #38793 /VacuumLog: Chamber: 0.85 mPa, 36.20 C, ForVacuum: 0.855 Pa, Gas: NULL, GasValve: 0.00 V 16:08:56 #38793 /VacuumLog: Chamber: 0.84 mPa, 36.20 C, ForVacuum: 0.86 Pa, Gas: NULL, GasValve: 0.00 V 16:08:57 #38793 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:09:00 #38793 /VacuumLog: Chamber: 0.84 mPa, 36.20 C, ForVacuum: 0.86 Pa, Gas: NULL, GasValve: 0.00 V 16:09:03 #38793 /VacuumLog: Chamber: 0.83 mPa, 36.20 C, ForVacuum: 0.86 Pa, Gas: NULL, GasValve: 0.00 V 16:09:07 #38793 /VacuumLog: Chamber: 0.83 mPa, 36.20 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:09:11 #38793 /VacuumLog: Chamber: 0.83 mPa, 36.20 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:09:14 #38793 /VacuumLog: Chamber: 0.83 mPa, 36.20 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:09:18 #38793 /VacuumLog: Chamber: 0.82 mPa, 36.20 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:09:21 #38793 /VacuumLog: Chamber: 0.82 mPa, 36.20 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:09:25 #38793 /VacuumLog: Chamber: 0.82 mPa, 36.20 C, ForVacuum: 0.865 Pa, Gas: NULL, GasValve: 0.00 V 16:09:29 #38793 /VacuumLog: Chamber: 0.82 mPa, 36.20 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:09:30 #38793 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:09:32 #38793 /VacuumLog: Chamber: 0.82 mPa, 36.20 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:09:36 #38793 /VacuumLog: Chamber: 0.82 mPa, 36.20 C, ForVacuum: 0.87 Pa, Gas: NULL, GasValve: 0.00 V 16:09:36 #38793 /DischargeFunction: General Calling FinalDischargeOperations