16:55:39 #38809 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Mix 16:55:39 #38809 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:55:41 #38809 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:55:41 #38809 /GetReadyTheDischarge: Going with gas pressure 10 16:55:42 #38809 /GetReadyTheDischarge: Going with gas type H 16:55:42 #38809 /GetReadyTheDischarge: Discharge with Hydrogen request 16:55:42 #38809 /GetReadyTheDischarge: Discharge with 10 mPa request 16:55:42 #38809 /VacuumLog: Chamber: 1.04 mPa, 49.50 C, ForVacuum: 0.93 Pa, Gas: H2, GasValve: 0.00 V arge: Going with Bt_orientation CW 16:55:42 #38809 /GetReadyTheDischarge: Discharge with Bt CW request 16:55:42 #38809 /GetReadyTheDischarge: Going with CD_orientation CW 16:55:42 #38809 /GetReadyTheDischarge: Discharge with CD CW request 16:55:45 #38809 /VacuumLog: Chamber: 1.27 mPa, 49.50 C, ForVacuum: 0.935 Pa, Gas: H2, GasValve: 22.01 V 16:55:49 #38809 /GetReadyTheDischarge: Bt capacitor charging started 16:55:49 #38809 /VacuumLog: Chamber: 4.86 mPa, 49.50 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 24.11 V 16:55:53 #38809 /VacuumLog: Chamber: 11.10 mPa, 49.40 C, ForVacuum: 2.45 Pa, Gas: H2, GasValve: 24.54 V 16:55:53 #38809 /GetReadyTheDischarge: Cd capacitor charging started 16:55:53 #38809 /ChargingResistorsAllOFF: Diving into .. 16:55:54 #38809 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 16:55:54 #38809 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 16:55:54 #38809 /GetReadyTheDischarge: Charging ... HV=-12 V 16:55:54 #38809 /GetReadyTheDischarge: Charging ... HV=-12 V 16:55:55 #38809 /GetReadyTheDischarge: Charging ... HV=-12 V 16:55:55 #38809 /GetReadyTheDischarge: Charging ... HV=13 V 16:55:55 #38809 /GetReadyTheDischarge: Charging ... HV=13 V 16:55:56 #38809 /GetReadyTheDischarge: Charging ... HV=62 V 16:55:56 #38809 /GetReadyTheDischarge: Charging ... HV=62 V 16:55:57 #38809 /GetReadyTheDischarge: Charging ... HV=62 V a, Gas: H2, GasValve: 23.64 V 16:55:57 #38809 /GetReadyTheDischarge: Charging ... HV=110 V 16:55:58 #38809 /GetReadyTheDischarge: Charging ... HV=110 V 16:55:58 #38809 /GetReadyTheDischarge: Charging ... HV=156 V 16:55:59 #38809 /GetReadyTheDischarge: Charging ... HV=156 V 16:55:59 #38809 /GetReadyTheDischarge: Charging ... HV=156 V 16:55:59 #38809 /GetReadyTheDischarge: Charging ... HV=202 V 16:56:00 #38809 /GetReadyTheDischarge: Charging ... HV=202 V 16:56:00 #38809 /GetReadyTheDischarge: Charging ... HV=248 V 16:56:01 #38809 /GetReadyTheDischarge: Charging ... HV=248 V 16:56:01 #38809 /GetReadyTheDischarge: Charging ... HV=292 V 16:56:02 #38809 /GetReadyTheDischarge: Charging ... HV=292 V 16:56:02 #38809 /GetReadyTheDischarge: Charging ... HV=292 V 16:56:02 #38809 /GetReadyTheDischarge: Charging ... HV=335 V 16:56:03 #38809 /GetReadyTheDischarge: Charging ... HV=335 V 16:56:03 #38809 /GetReadyTheDischarge: Charging ... HV=375 V 16:56:04 #38809 /VacuumLog: Chamber: 10.30 mPa, 49.40 C, ForVacuum: 3.3 Pa, Gas: H2, GasValve: 23.64 V 16:56:04 #38809 /GetReadyTheDischarge: Charging ... HV=375 V 16:56:04 #38809 /GetReadyTheDischarge: Charging ... HV=375 V 16:56:05 #38809 /GetReadyTheDischarge: Charging ... HV=414 V 16:56:05 #38809 /GetReadyTheDischarge: Charging ... HV=414 V 16:56:06 #38809 /GetReadyTheDischarge: Charging ... HV=454 V 16:56:06 #38809 /GetReadyTheDischarge: Cd capacitor charging finished @ 454 V 16:56:06 #38809 /GetReadyTheDischarge: Charging ... HV=454 V 16:56:06 #38809 /GetReadyTheDischarge: Charging ... HV=491 V 16:56:07 #38809 /GetReadyTheDischarge: Charging ... HV=491 V 16:56:07 #38809 /GetReadyTheDischarge: Charging ... HV=491 V 16:56:07 #38809 /VacuumLog: Chamber: 10.20 mPa, 49.40 C, ForVacuum: 3.25 Pa, Gas: H2, GasValve: 23.64 V 16:56:08 #38809 /GetReadyTheDischarge: Charging ... HV=531 V 16:56:08 #38809 /GetReadyTheDischarge: Charging ... HV=531 V 16:56:09 #38809 /GetReadyTheDischarge: Charging ... HV=531 V 16:56:09 #38809 /GetReadyTheDischarge: Charging ... HV=570 V 16:56:09 #38809 /GetReadyTheDischarge: Charging ... HV=570 V 16:56:10 #38809 /GetReadyTheDischarge: Charging ... HV=608 V 16:56:10 #38809 /GetReadyTheDischarge: Charging ... HV=608 V 16:56:11 #38809 /GetReadyTheDischarge: Charging ... HV=608 V 16:56:11 #38809 /GetReadyTheDischarge: Charging ... HV=642 V , Gas: H2, GasValve: 23.64 V 16:56:12 #38809 /GetReadyTheDischarge: Charging ... HV=642 V 16:56:12 #38809 /GetReadyTheDischarge: Charging ... HV=680 V 16:56:12 #38809 /GetReadyTheDischarge: Charging ... HV=680 V 16:56:13 #38809 /GetReadyTheDischarge: Charging ... HV=680 V 16:56:13 #38809 /GetReadyTheDischarge: Charging ... HV=715 V 16:56:14 #38809 /GetReadyTheDischarge: Charging ... HV=715 V 16:56:14 #38809 /GetReadyTheDischarge: Charging ... HV=748 V 16:56:15 #38809 /GetReadyTheDischarge: Charging ... HV=748 V 16:56:15 #38809 /GetReadyTheDischarge: Charging ... HV=748 V , Gas: H2, GasValve: 23.64 V 16:56:15 #38809 /GetReadyTheDischarge: Charging ... HV=779 V 16:56:16 #38809 /GetReadyTheDischarge: Charging ... HV=779 V 16:56:16 #38809 /GetReadyTheDischarge: Charging ... HV=810 V 16:56:16 #38809 /ChargingResistorsAllON: Diving into .. 16:56:17 #38809 /GetReadyTheDischarge: Bt capacitor charging finished @ 810 V 16:56:17 #38809 /ChargingResistorsAllON: Diving into .. 16:56:17 #38809 /GetReadyTheDischarge: Ascending from .. 16:56:17 #38809 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:56:18 #38809 /VacuumLog: Chamber: 10.10 mPa, 49.40 C, ForVacuum: 3.25 Pa, Gas: H2, GasValve: 23.64 V 16:56:19 #38809 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:56:19 #38809 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:56:20 #38809 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:56:22 #38809 /VacuumLog: Chamber: 10.10 mPa, 49.30 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.64 V 16:56:26 #38809 /VacuumLog: Chamber: 10.10 mPa, 49.30 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.64 V 16:56:29 #38809 /VacuumLog: Chamber: 10.10 mPa, 49.40 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.64 V 16:56:31 #38809 /Trigger: Going through .. 16:56:31 #38809 Discharge/HWTrigger: Going through .. 16:56:31 #38809 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 16:56:31 #38809 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 16:56:31 #38809 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 16:56:33 #38809 /VacuumLog: Chamber: 10.00 mPa, 49.30 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.64 V 16:56:35 #38809 /ChargingResistorsAllON: Diving into .. 16:56:37 #38809 /VacuumLog: Chamber: 9.21 mPa, 49.30 C, ForVacuum: 3.15 Pa, Gas: H2, GasValve: 0.00 V 16:56:38 #38809 /SecurePostDischargeState: Going through .. 16:56:38 #38809 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:56:40 #38809 /VacuumLog: Chamber: 1.17 mPa, 49.30 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 16:56:43 #38809 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:56:44 #38809 /VacuumLog: Chamber: 1.09 mPa, 49.30 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V 16:56:46 #38809 Papouch-St/RawDataAcquiring: Papouch-St: Start of acquiring 16:56:47 #38809 /VacuumLog: Chamber: 1.05 mPa, 49.30 C, ForVacuum: 0.9 Pa, Gas: NULL, GasValve: 0.00 V 16:56:51 #38809 /VacuumLog: Chamber: 1.04 mPa, 49.30 C, ForVacuum: 0.9 Pa, Gas: NULL, GasValve: 0.00 V 16:56:53 #38809 Papouch-St/RawDataAcquiring: Papouch-St: End of acquiring 16:56:55 #38809 /VacuumLog: Chamber: 1.03 mPa, 49.30 C, ForVacuum: 0.905 Pa, Gas: NULL, GasValve: 0.00 V 16:56:58 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.30 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 16:57:02 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.30 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 16:57:06 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.20 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 16:57:09 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.20 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 16:57:12 #38809 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:57:13 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.20 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 16:57:16 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.30 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 16:57:17 #38809 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:57:20 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.20 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 16:57:24 #38809 /VacuumLog: Chamber: 1.02 mPa, 49.20 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 16:57:24 #38809 /DischargeFunction: General Calling FinalDischargeOperations