17:43:15 #38816 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Mix 17:43:15 #38816 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 17:43:17 #38816 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 17:43:17 #38816 /GetReadyTheDischarge: Going with gas pressure 0 17:43:17 #38816 /GetReadyTheDischarge: Going with gas type H 17:43:17 #38816 /GetReadyTheDischarge: Vacuum discharge ! 17:43:17 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V yTheDischarge: Going with Bt_orientation CW 17:43:17 #38816 /GetReadyTheDischarge: Discharge with Bt CW request 17:43:17 #38816 /GetReadyTheDischarge: Going with CD_orientation CW 17:43:17 #38816 /GetReadyTheDischarge: Discharge with CD CW request 17:43:21 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:24 #38816 /GetReadyTheDischarge: Bt capacitor charging started 17:43:25 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:28 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:29 #38816 /GetReadyTheDischarge: Cd capacitor charging started 17:43:29 #38816 /ChargingResistorsAllOFF: Diving into .. 17:43:29 #38816 /GetReadyTheDischarge: U_Bt: 220, Hrana: 98 17:43:29 #38816 /GetReadyTheDischarge: U_Et: 220, Hrana: 98 17:43:29 #38816 /GetReadyTheDischarge: Charging ... HV=-13 V 17:43:29 #38816 /GetReadyTheDischarge: Charging ... HV=-13 V 17:43:30 #38816 /GetReadyTheDischarge: Charging ... HV=3 V 17:43:30 #38816 /GetReadyTheDischarge: Charging ... HV=3 V 17:43:31 #38816 /GetReadyTheDischarge: Charging ... HV=3 V 17:43:31 #38816 /GetReadyTheDischarge: Charging ... HV=50 V 17:43:32 #38816 /GetReadyTheDischarge: Charging ... HV=50 V 17:43:32 #38816 /GetReadyTheDischarge: Charging ... HV=98 V , Gas: NULL, GasValve: 0.00 V 17:43:33 #38816 /GetReadyTheDischarge: Charging ... HV=98 V 17:43:33 #38816 /GetReadyTheDischarge: Charging ... HV=98 V 17:43:33 #38816 /GetReadyTheDischarge: Charging ... HV=145 V 17:43:34 #38816 /GetReadyTheDischarge: Charging ... HV=145 V 17:43:34 #38816 /GetReadyTheDischarge: Charging ... HV=191 V 17:43:35 #38816 /GetReadyTheDischarge: Charging ... HV=191 V 17:43:35 #38816 /GetReadyTheDischarge: Charging ... HV=237 V 17:43:35 #38816 /GetReadyTheDischarge: Bt capacitor charging finished @ 237 V 17:43:36 #38816 /ChargingResistorsAllON: Diving into .. 17:43:36 #38816 /GetReadyTheDischarge: Cd capacitor charging finished @ 237 V 17:43:36 #38816 /ChargingResistorsAllON: Diving into .. 17:43:36 #38816 /GetReadyTheDischarge: Ascending from .. 17:43:36 #38816 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 17:43:38 #38816 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:43:38 #38816 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:43:39 #38816 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 17:43:39 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:43 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:46 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:50 #38816 /Trigger: Going through .. 17:43:50 #38816 Discharge/HWTrigger: Going through .. 17:43:50 #38816 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 17:43:50 #38816 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 17:43:50 #38816 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 17:43:50 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:54 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.90 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:43:54 #38816 /ChargingResistorsAllON: Diving into .. 17:43:57 #38816 /SecurePostDischargeState: Going through .. 17:43:57 #38816 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 17:43:57 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:01 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:02 #38816 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 17:44:04 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:08 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:12 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:15 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:19 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.70 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:23 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:26 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:30 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:30 #38816 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 17:44:34 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:34 #38816 Papouch-St/RawDataAcquiring: Papouch-St: Start of acquiring 17:44:37 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:41 #38816 Papouch-St/RawDataAcquiring: Papouch-St: End of acquiring 17:44:41 #38816 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 17:44:41 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:44:44 #38816 /DischargeFunction: General Calling FinalDischargeOperations 17:44:45 #38816 /VacuumLog: Chamber: 1.00 mPa, 43.60 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V