17:29:41 #38842 /VacuumLog: Chamber: 0.96 mPa, 38.20 C, ForVacuum: 0.92 Pa, Gas: NULL, GasValve: 0.00 V 17:29:41 #38842 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Extended essay, gymn. Novy PORG, Plasma regimes according to technological parameters 17:29:41 #38842 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 17:29:43 #38842 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 17:29:43 #38842 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 17:29:43 #38842 /GetReadyTheDischarge: Going with gas pressure 10 17:29:44 #38842 /GetReadyTheDischarge: Going with gas type H 17:29:44 17:29:44 #38842 /GetReadyTheDischarge: Discharge with Hydrogen request 17:29:44 #38842 /GetReadyTheDischarge: Discharge with 10 mPa request 17:29:44 #38842 /GetReadyTheDischarge: Going with CD_orientation CW 17:29:44 #38842 /GetReadyTheDischarge: Discharge with CD CW request 17:29:45 #38842 /VacuumLog: Chamber: 0.96 mPa, 38.10 C, ForVacuum: 0.92 Pa, Gas: H2, GasValve: 21.13 V 17:29:48 #38842 /VacuumLog: Chamber: 1.79 mPa, 38.10 C, ForVacuum: 0.98 Pa, Gas: H2, GasValve: 22.86 V 17:29:51 #38842 /GetReadyTheDischarge: Bt capacitor charging started 17:29:52 #38842 /VacuumLog: Chamber: 6.92 mPa, 38.10 C, ForVacuum: 1.65 Pa, Gas: H2, GasValve: 24.05 V 17:29:55 #38842 /GetReadyTheDischarge: Cd capacitor charging started 17:29:55 #38842 /ChargingResistorsAllOFF: Diving into .. 17:29:55 #38842 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 17:29:55 #38842 /GetReadyTheDischarge: U_Et: 400, Hrana: 98 17:29:55 #38842 /GetReadyTheDischarge: Charging ... HV=-12 V 17:29:56 #38842 /GetReadyTheDischarge: Charging ... HV=-8 V a, Gas: H2, GasValve: 24.16 V 17:29:56 #38842 /GetReadyTheDischarge: Charging ... HV=-8 V 17:29:57 #38842 /GetReadyTheDischarge: Charging ... HV=27 V 17:29:57 #38842 /GetReadyTheDischarge: Charging ... HV=27 V 17:29:58 #38842 /GetReadyTheDischarge: Charging ... HV=27 V 17:29:58 #38842 /GetReadyTheDischarge: Charging ... HV=77 V 17:29:59 #38842 /GetReadyTheDischarge: Charging ... HV=77 V 17:29:59 #38842 /GetReadyTheDischarge: Charging ... HV=124 V 17:29:59 #38842 /GetReadyTheDischarge: Charging ... HV=124 V 17:30:00 #38842 /GetReadyTheDischarge: Charging ... HV=124 V 17:30:00 #38842 /GetReadyTheDischarge: Charging ... HV=171 V 17:30:01 #38842 /GetReadyTheDischarge: Charging ... HV=171 V 17:30:01 #38842 /GetReadyTheDischarge: Charging ... HV=219 V 17:30:02 #38842 /GetReadyTheDischarge: Charging ... HV=219 V 17:30:02 #38842 /GetReadyTheDischarge: Charging ... HV=265 V 17:30:02 #38842 /GetReadyTheDischarge: Charging ... HV=265 V 17:30:03 #38842 /VacuumLog: Chamber: 11.70 mPa, 38.10 C, ForVacuum: 3.65 Pa, Gas: H2, GasValve: 23.44 V 17:30:03 #38842 /GetReadyTheDischarge: Charging ... HV=265 V 17:30:03 #38842 /GetReadyTheDischarge: Charging ... HV=311 V 17:30:04 #38842 /GetReadyTheDischarge: Charging ... HV=311 V 17:30:04 #38842 /GetReadyTheDischarge: Charging ... HV=353 V 17:30:05 #38842 /GetReadyTheDischarge: Charging ... HV=353 V 17:30:05 #38842 /GetReadyTheDischarge: Charging ... HV=353 V 17:30:06 #38842 /GetReadyTheDischarge: Charging ... HV=393 V 17:30:06 #38842 /GetReadyTheDischarge: Cd slow PowSup 17:30:06 #38842 /ChargingResistorsAllON: Diving into .. 17:30:06 #38842 /GetReadyTheDischarge: Charging ... HV=393 V 17:30:06 #38842 /VacuumLog: Chamber: 11.70 mPa, 38.10 C, ForVacuum: 3.6 Pa, Gas: H2, GasValve: 23.44 V 17:30:07 #38842 /GetReadyTheDischarge: Charging ... HV=431 V 17:30:07 #38842 /GetReadyTheDischarge: Cd capacitor charging finished @ 431 V 17:30:07 #38842 /GetReadyTheDischarge: Bt boost PowSup 17:30:07 #38842 /ChargingResistorsAllOFF: Diving into .. 17:30:07 #38842 /GetReadyTheDischarge: Charging ... HV=431 V 17:30:08 #38842 /GetReadyTheDischarge: Charging ... HV=443 V 17:30:08 #38842 /GetReadyTheDischarge: Charging ... HV=443 V 17:30:09 #38842 /GetReadyTheDischarge: Charging ... HV=479 V 17:30:09 #38842 /GetReadyTheDischarge: Charging ... HV=479 V 17:30:09 #38842 /GetReadyTheDischarge: Charging ... HV=479 V 17:30:10 #38842 /GetReadyTheDischarge: Charging ... HV=520 V 17:30:10 #38842 /VacuumLog: Chamber: 11.70 mPa, 38.10 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 23.44 V 17:30:10 #38842 /GetReadyTheDischarge: Charging ... HV=520 V 17:30:11 #38842 /GetReadyTheDischarge: Charging ... HV=560 V 17:30:11 #38842 /GetReadyTheDischarge: Charging ... HV=560 V 17:30:11 #38842 /GetReadyTheDischarge: Charging ... HV=23 V 17:30:12 #38842 /GetReadyTheDischarge: Charging ... HV=599 V 17:30:12 #38842 /GetReadyTheDischarge: Charging ... HV=599 V 17:30:13 #38842 /GetReadyTheDischarge: Charging ... HV=599 V 17:30:13 #38842 /GetReadyTheDischarge: Charging ... HV=636 V 17:30:14 #38842 /GetReadyTheDischarge: Charging ... HV=636 V 17:30:14 #38842 /VacuumLog: Chamber: 11.70 mPa, 38.10 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 23.44 V 17:30:14 #38842 /GetReadyTheDischarge: Charging ... HV=23 V 17:30:14 #38842 /GetReadyTheDischarge: Charging ... HV=674 V 17:30:15 #38842 /GetReadyTheDischarge: Charging ... HV=674 V 17:30:15 #38842 /GetReadyTheDischarge: Charging ... HV=711 V 17:30:16 #38842 /GetReadyTheDischarge: Charging ... HV=711 V 17:30:16 #38842 /GetReadyTheDischarge: Charging ... HV=745 V 17:30:17 #38842 /GetReadyTheDischarge: Charging ... HV=745 V 17:30:17 #38842 /GetReadyTheDischarge: Charging ... HV=23 V 17:30:17 #38842 /GetReadyTheDischarge: Charging ... HV=778 V 17:30:17 #38842 /VacuumLog: Chamber: 11.70 mPa, 38.10 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 23.44 V 17:30:18 #38842 /GetReadyTheDischarge: Charging ... HV=778 V 17:30:18 #38842 /GetReadyTheDischarge: Charging ... HV=810 V 17:30:19 #38842 /ChargingResistorsAllON: Diving into .. 17:30:19 #38842 /GetReadyTheDischarge: Bt capacitor charging finished @ 810 V 17:30:19 #38842 /ChargingResistorsAllON: Diving into .. 17:30:19 #38842 /GetReadyTheDischarge: Ascending from .. 17:30:19 #38842 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 17:30:21 #38842 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:30:21 #38842 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:30:21 #38842 /VacuumLog: Chamber: 11.60 mPa, 38.10 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 23.44 V 17:30:21 #38842 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 17:30:25 #38842 /VacuumLog: Chamber: 11.60 mPa, 38.00 C, ForVacuum: 3.5 Pa, Gas: H2, GasValve: 23.44 V 17:30:28 #38842 /VacuumLog: Chamber: 11.60 mPa, 38.10 C, ForVacuum: 3.5 Pa, Gas: H2, GasValve: 23.44 V 17:30:32 #38842 /Trigger: Going through .. 17:30:32 #38842 Discharge/HWTrigger: Going through .. 17:30:32 #38842 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 17:30:32 #38842 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 17:30:32 #38842 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 asValve: 23.44 V 17:30:36 #38842 /VacuumLog: Chamber: 11.10 mPa, 38.10 C, ForVacuum: 3.35 Pa, Gas: H2, GasValve: 23.44 V 17:30:36 #38842 /ChargingResistorsAllON: Diving into .. 17:30:39 #38842 /SecurePostDischargeState: Going through .. 17:30:39 #38842 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 17:30:39 #38842 /VacuumLog: Chamber: 1.82 mPa, 38.10 C, ForVacuum: 2.85 Pa, Gas: NULL, GasValve: 0.00 V 17:30:43 #38842 /VacuumLog: Chamber: 1.18 mPa, 38.10 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:30:44 #38842 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 17:30:47 #38842 /VacuumLog: Chamber: 1.12 mPa, 38.10 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 17:30:50 #38842 /VacuumLog: Chamber: 1.08 mPa, 38.10 C, ForVacuum: 0.895 Pa, Gas: NULL, GasValve: 0.00 V 17:30:54 #38842 /VacuumLog: Chamber: 1.06 mPa, 38.10 C, ForVacuum: 0.9 Pa, Gas: NULL, GasValve: 0.00 V 17:30:55 #38842 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 17:30:57 #38842 /VacuumLog: Chamber: 1.04 mPa, 38.10 C, ForVacuum: 0.905 Pa, Gas: NULL, GasValve: 0.00 V 17:31:01 #38842 /VacuumLog: Chamber: 1.02 mPa, 38.10 C, ForVacuum: 0.905 Pa, Gas: NULL, GasValve: 0.00 V 17:31:05 #38842 /VacuumLog: Chamber: 1.01 mPa, 38.10 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:31:08 #38842 /VacuumLog: Chamber: 1.00 mPa, 38.10 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:31:12 #38842 /VacuumLog: Chamber: 0.99 mPa, 38.10 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:31:16 #38842 /VacuumLog: Chamber: 0.98 mPa, 38.10 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:31:19 #38842 /VacuumLog: Chamber: 0.98 mPa, 38.10 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:31:23 #38842 /VacuumLog: Chamber: 0.97 mPa, 38.10 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:31:27 #38842 /VacuumLog: Chamber: 0.97 mPa, 38.00 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:31:28 #38842 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 17:31:30 #38842 /VacuumLog: Chamber: 0.97 mPa, 38.00 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:31:34 #38842 /VacuumLog: Chamber: 0.96 mPa, 38.10 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:31:36 #38842 /DischargeFunction: General Calling FinalDischargeOperations 17:31:38 #38842 /VacuumLog: Chamber: 0.96 mPa, 38.10 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V