12:18:31 #38854 Discharge/PrepareDischargeEnv@SHM: Command Line Request: UPP 12:18:31 #38854 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 12:18:33 #38854 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 12:18:33 #38854 /GetReadyTheDischarge: Going with gas pressure 6 12:18:33 #38854 /GetReadyTheDischarge: Going with gas type H 12:18:33 #38854 /GetReadyTheDischarge: Discharge with Hydrogen requ12:18:33 #38854 /12:18:33 #38854 /GetReadyTheDischarge: Discharge with 6 mPa requ12:18:33 #38854 /12:18:33 #38854 /VacuumLog: Chamber: 1.02 mPa, 45.20 C, ForVacuum: 0.99 Pa, Gas: H2, GasValve: 0.00 V _orientation CW 12:18:33 #38854 /GetReadyTheDischarge: Discharge with CD CW request 12:18:37 #38854 /VacuumLog: Chamber: 1.31 mPa, 45.10 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 21.40 V 12:18:40 #38854 /GetReadyTheDischarge: Bt capacitor charging started 12:18:41 #38854 /VacuumLog: Chamber: 1.92 mPa, 45.10 C, ForVacuum: 1.15 Pa, Gas: H2, GasValve: 22.23 V 12:18:44 #38854 /VacuumLog: Chamber: 4.27 mPa, 45.10 C, ForVacuum: 1.55 Pa, Gas: H2, GasValve: 22.73 V 12:18:45 #38854 /GetReadyTheDischarge: Cd capacitor charging started 12:18:45 #38854 /ChargingResistorsAllOFF: Diving into .. 12:18:45 #38854 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 12:18:45 #38854 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 12:18:45 #38854 /GetReadyTheDischarge: Charging ... HV=-12 V 12:18:46 #38854 /GetReadyTheDischarge: Charging ... HV=-12 V 12:18:46 #38854 /GetReadyTheDischarge: Charging ... HV=3 V 12:18:46 #38854 /GetReadyTheDischarge: Charging ... HV=3 V 12:18:47 #38854 /GetReadyTheDischarge: Charging ... HV=3 V 12:18:47 #38854 /GetReadyTheDischarge: Charging ... HV=48 V 12:18:48 #38854 /GetReadyTheDischarge: Charging ... HV=48 V 12:18:48 #38854 /GetReadyTheDischarge: Charging ... HV=95 V Gas: H2, GasValve: 23.01 V 12:18:49 #38854 /GetReadyTheDischarge: Charging ... HV=95 V 12:18:49 #38854 /GetReadyTheDischarge: Charging ... HV=141 V 12:18:49 #38854 /GetReadyTheDischarge: Charging ... HV=141 V 12:18:50 #38854 /GetReadyTheDischarge: Charging ... HV=141 V 12:18:50 #38854 /GetReadyTheDischarge: Charging ... HV=186 V 12:18:51 #38854 /GetReadyTheDischarge: Charging ... HV=186 V 12:18:51 #38854 /GetReadyTheDischarge: Charging ... HV=232 V 12:18:52 #38854 /GetReadyTheDischarge: Charging ... HV=232 V 12:18:52 #38854 /GetReadyTheDischarge: Charging ... HV=232 V Gas: H2, GasValve: 23.01 V 12:18:52 #38854 /GetReadyTheDischarge: Charging ... HV=275 V 12:18:53 #38854 /GetReadyTheDischarge: Charging ... HV=275 V 12:18:53 #38854 /GetReadyTheDischarge: Charging ... HV=319 V 12:18:54 #38854 /GetReadyTheDischarge: Charging ... HV=319 V 12:18:54 #38854 /GetReadyTheDischarge: Charging ... HV=319 V 12:18:55 #38854 /GetReadyTheDischarge: Charging ... HV=359 V 12:18:55 #38854 /GetReadyTheDischarge: Charging ... HV=359 V 12:18:56 #38854 /GetReadyTheDischarge: Charging ... HV=397 V 12:18:56 #38854 /GetReadyTheDischarge: Charging ... HV=397 V 12:18:56 #38854 /GetReadyTheDischarge: Charging ... HV=397 V 12:18:57 #38854 /GetReadyTheDischarge: Charging ... HV=435 V 12:18:57 #38854 /GetReadyTheDischarge: Charging ... HV=435 V 12:18:58 #38854 /GetReadyTheDischarge: Charging ... HV=474 V 12:18:58 #38854 /GetReadyTheDischarge: Cd capacitor charging finished @ 474 V 12:18:58 #38854 /GetReadyTheDischarge: Charging ... HV=474 V 12:18:59 #38854 /GetReadyTheDischarge: Charging ... HV=509 V 12:18:59 #38854 /VacuumLog: Chamber: 7.72 mPa, 45.00 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 23.01 V 12:18:59 #38854 /GetReadyTheDischarge: Charging ... HV=509 V 12:19:00 #38854 /GetReadyTheDischarge: Charging ... HV=509 V 12:19:00 #38854 /GetReadyTheDischarge: Charging ... HV=548 V 12:19:00 #38854 /GetReadyTheDischarge: Charging ... HV=548 V 12:19:01 #38854 /GetReadyTheDischarge: Charging ... HV=586 V 12:19:01 #38854 /GetReadyTheDischarge: Charging ... HV=586 V 12:19:02 #38854 /GetReadyTheDischarge: Charging ... HV=586 V 12:19:02 #38854 /GetReadyTheDischarge: Charging ... HV=621 V 12:19:02 #38854 /GetReadyTheDischarge: Charging ... HV=621 V 12:19:03 #38854 /VacuumLog: Chamber: 7.86 mPa, 45.10 C, ForVacuum: 2.8 Pa, Gas: H2, GasValve: 23.01 V 12:19:03 #38854 /GetReadyTheDischarge: Charging ... HV=621 V 12:19:03 #38854 /GetReadyTheDischarge: Charging ... HV=655 V 12:19:04 #38854 /GetReadyTheDischarge: Charging ... HV=655 V 12:19:04 #38854 /GetReadyTheDischarge: Charging ... HV=692 V 12:19:05 #38854 /GetReadyTheDischarge: Charging ... HV=692 V 12:19:05 #38854 /GetReadyTheDischarge: Charging ... HV=692 V 12:19:05 #38854 /GetReadyTheDischarge: Charging ... HV=725 V 12:19:06 #38854 /GetReadyTheDischarge: Charging ... HV=725 V 12:19:06 #38854 /GetReadyTheDischarge: Charging ... HV=757 V 12:19:06 #38854 /VacuumLog: Chamber: 7.97 mPa, 45.00 C, ForVacuum: 2.85 Pa, Gas: H2, GasValve: 23.01 V 12:19:07 #38854 /GetReadyTheDischarge: Charging ... HV=757 V 12:19:07 #38854 /GetReadyTheDischarge: Charging ... HV=757 V 12:19:08 #38854 /GetReadyTheDischarge: Charging ... HV=788 V 12:19:08 #38854 /GetReadyTheDischarge: Bt slow PowSup 12:19:08 #38854 /ChargingResistorsAllON: Diving into .. 12:19:08 #38854 /GetReadyTheDischarge: Charging ... HV=788 V 12:19:09 #38854 /GetReadyTheDischarge: Charging ... HV=816 V 12:19:09 #38854 /ChargingResistorsAllON: Diving into .. 12:19:09 #38854 /GetReadyTheDischarge: Bt capacitor charging finished @ 816 V 12:19:09 #38854 /ChargingResistorsAllON: Diving into .. 12:19:10 #38854 /GetReadyTheDischarge: Ascending from .. 12:19:10 #38854 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 12:19:10 #38854 /VacuumLog: Chamber: 8.04 mPa, 45.00 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 23.01 V 12:19:11 #38854 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:19:11 #38854 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:19:12 #38854 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 12:19:14 #38854 /VacuumLog: Chamber: 8.09 mPa, 45.00 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 23.01 V 12:19:17 #38854 /VacuumLog: Chamber: 8.14 mPa, 45.00 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 23.01 V 12:19:21 #38854 /VacuumLog: Chamber: 8.18 mPa, 45.00 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 23.01 V 12:19:22 #38854 /Trigger: Going through .. 12:19:22 #38854 Discharge/HWTrigger: Going through .. 12:19:22 #38854 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 12:19:22 #38854 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 12:19:22 #38854 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 12:19:24 #38854 /VacuumLog: Chamber: 8.23 mPa, 44.90 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 23.01 V 12:19:27 #38854 /ChargingResistorsAllON: Diving into .. 12:19:28 #38854 /VacuumLog: Chamber: 7.70 mPa, 45.00 C, ForVacuum: 2.8 Pa, Gas: H2, GasValve: 0.00 V 12:19:29 #38854 /SecurePostDischargeState: Going through .. 12:19:29 #38854 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 12:19:32 #38854 /VacuumLog: Chamber: 1.14 mPa, 45.00 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 12:19:34 #38854 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 12:19:35 #38854 /VacuumLog: Chamber: 1.08 mPa, 45.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 12:19:39 #38854 /VacuumLog: Chamber: 1.06 mPa, 45.00 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 12:19:42 #38854 /VacuumLog: Chamber: 1.05 mPa, 45.00 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 12:19:46 #38854 /VacuumLog: Chamber: 1.04 mPa, 44.90 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 12:19:50 #38854 /VacuumLog: Chamber: 1.03 mPa, 45.00 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 12:19:53 #38854 /VacuumLog: Chamber: 1.03 mPa, 44.90 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 12:19:57 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.90 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:20:01 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.90 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:20:04 #38854 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 12:20:04 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.90 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:20:08 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.90 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:20:12 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.90 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:20:15 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.90 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:20:16 #38854 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 12:20:19 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.90 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:20:22 #38854 /DischargeFunction: General Calling FinalDischargeOperations 12:20:22 #38854 /VacuumLog: Chamber: 1.02 mPa, 44.80 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V