%matplotlib inline
import numpy as np
import matplotlib.pyplot as plt
import pandas as pd
from scipy import constants
from scipy import signal as sigproc
from scipy.fft import next_fast_len
shot_no = 38858
!pip3 install isfreader
Requirement already satisfied: isfreader in /opt/anaconda3/lib/python3.8/site-packages (1.0.0) Requirement already satisfied: numpy>=1.9.1 in /opt/anaconda3/lib/python3.8/site-packages (from isfreader) (1.19.2)
import isfreader
ds = np.DataSource('/tmp') # temporary sotarge for downloaded files
data_URL = 'http://golem.fjfi.cvut.cz/shots/{shot_no}/Diagnostics/Interferometry/DAS_raw_data_dir/ch{ch_id}.isf'
scalars_URL = 'http://golem.fjfi.cvut.cz/shots/{shot_no}/Diagnostics/BasicDiagnostics/Results/{name}'
def get_scalar(shot_no, name):
return float(ds.open(scalars_URL.format(shot_no=shot_no, name=name)).read())
t_plasma_start = get_scalar(shot_no, 't_plasma_start')
t_plasma_end = get_scalar(shot_no, 't_plasma_end')
is_plasma = get_scalar(shot_no, 'is_plasma')
def load_channel(shot_no, chanel_id, channel_name=None, in_ms=True):
fname = ds.open(data_URL.format(shot_no=shot_no, ch_id=chanel_id)).name
data = isfreader.read_file(fname)
signal = pd.Series(data[:,1], name=channel_name,
index=pd.Index(data[:,0], name='time'))
if in_ms:
signal.index *= 1e3 # s -> ms
return signal
mixer = load_channel(shot_no, 1, 'mixer')
ref_saw = load_channel(shot_no, 3, 'ref_saw')
Sampling frequency in kHz
f_s = mixer.size / (mixer.index[-1] - mixer.index[0]) # ms -> kHz
f_s
250000.05000001
The mixer signals is a base sine wave (the envelope of the mixing) at a frequency close to 500 kHz. The reference saw-tooth frequency sweeping wave has the same base frequency, but with a trail of harmonics forming the sharp saw-tooth shape.
def show_spectrum(signal, target_dfreq=10):
nperseg = int(f_s / target_dfreq)
f, psd = sigproc.welch(signal.values, fs=f_s,
nperseg=nperseg, nfft=next_fast_len(nperseg))
f_max = f[psd.argmax()]
ax = plt.gca()
ax.plot(f, psd, label=signal.name)
ax.set(xlabel='frequency [kHz]', ylabel='power spectral density [V^2]')
return f_max
show_spectrum(ref_saw)
f_base = show_spectrum(mixer)
plt.axvline(f_base, label=f'base frequency f={f_base:.0f} kHz', color='C3')
plt.loglog()
plt.legend()
f_base
510.0001020000204
The difference between the phase of the reference and mixer signal is proportional to the line-integrated electron density. Therefore, it is necessary to obtain the "phase" of both signals.
The instantanous phase and amplitude of the base signal can be inferred only for the base bad, i.e. by removing higher and lower frequencies (i.e. extracting the base sine wave from the reference saw-tooth signal)
base_band_hwidth = 50 # kHz
base_band_filter = sigproc.iirfilter(8,
[f_base - base_band_hwidth, f_base+base_band_hwidth],
fs=f_s,
btype='bandpass', output='sos')
def freq_filter(signal, sos_filter):
return pd.Series(name=signal.name+'_filtered', index=signal.index,
data=sigproc.sosfiltfilt(sos_filter, signal.values))
mixer_filtered = freq_filter(mixer, base_band_filter)
ref_saw_filtered = freq_filter(ref_saw, base_band_filter)
The instantanous phase and amplitude of this base band signal can be obtained from the analytic signal using the Hilbert transform. For convenience of processing and visualization, the phase is unwrapped ($\pi$ discontinuities are shifted) and it's time derivative, the instantaneous frequency, is calucated as well.
def inst_phase_amp(signal):
analytic_signal = sigproc.hilbert(signal.values)
inst_phase = pd.Series(np.unwrap(np.angle(analytic_signal)),
index=signal.index,
name=signal.name+'_inst_phase')
# remove base band phase evolution trend
inst_freq = pd.Series(np.gradient(inst_phase, inst_phase.index),
index=inst_phase.index, name=signal.name+'_inst_freq')
inst_amp = pd.Series(np.abs(analytic_signal), index=signal.index,
name=signal.name+'_inst_amp')
return inst_phase, inst_freq, inst_amp
mixer_phase, mixer_freq, mixer_amp = inst_phase_amp(mixer_filtered)
ref_saw_phase, ref_saw_freq, ref_saw_amp = inst_phase_amp(ref_saw_filtered)
For convenience of visualization it is convenient to subtract the phase evolution of the base nad signal from the phases (which is just a linear trend). This base trend vanishes in the final phase difference calculation anyways as long as the same trend is removed. Therefore, the referense saw-tooth signals is used for the trend estimation.
omega_base_ref = ref_saw_freq.median()
mixer_dfreq = mixer_freq - omega_base_ref
mixer_dphase = mixer_dfreq.cumsum() / f_s
ref_saw_dphase = (ref_saw_freq - omega_base_ref).cumsum() / f_s
omega_base_ref / (2*np.pi)
513.6982786301003
mixer_freq.loc[-1:0].median() / (2*np.pi)
513.6592875560722
The signal boundaries may be distorted by the filter, so they are not used.
boundary_Dt = 0.5 # in ms
in_boundary = slice(mixer_dfreq.index[0]+boundary_Dt,
mixer_dfreq.index[-1] - boundary_Dt)
in_boundary
slice(-1.0035, 17.996496, None)
ref_saw_dphase.loc[in_boundary].plot()
mixer_dphase.loc[in_boundary].plot()
plt.legend();
<matplotlib.legend.Legend at 0x7f8d229cb040>
The phase difference between the interferometer signal with respect to the reference signal is proportional to the line-averaged density. An arbitrary initial phase difference is subtracted.
dphase = pd.Series(ref_saw_dphase - mixer_dphase,
index=mixer.index, name='dphase')
dphase -= dphase.loc[-1:0].mean()
fig, axs = plt.subplots(2, 1, sharex=True, figsize=(8, 8))
plt.sca(axs[0])
mixer_amp.loc[in_boundary].plot()
axs[0].set(ylabel='mixer amplitude')
plt.sca(axs[1])
dphase.loc[in_boundary].plot()
if not is_plasma:
plt.savefig('icon-fig.png')
The ordinary wave (O-mode) with a carrier frequency $\omega$ traveling through a collisionless plasma with the plasma frequency $\omega_{p} = \sqrt{\frac{n_e e^2}{\epsilon_0 m_e}}$ has a refractive index $$N_O=\sqrt{1-\frac{\omega_p^2}{\omega^2}}$$ Under the assumption that the carrier wave frequency is much larger than the plasma frequency $\omega>>\omega_p$ this formula can be expanded into a Taylor series as $$N_O\approx 1-\frac{\omega_p^2}{2\omega^2}$$ A wave traveling through a medium with a refractive index $N(l)$ accumulates a total phase shift $\varphi = \frac{\omega}{c} \int N(l) \mathrm{d}l$. Therefore, in comparison to a wave traveling in vacuum (or clear air) with $N\approx 1$, the wave traveling through the plasma over a chord with length $L$ accumulates a relative phase shift of $$\Delta \varphi = \frac{e^2}{2\omega c\epsilon_0 m_e}\int\limits_L n_e(l) \mathrm{d}l$$ Therefore, it is possible to estimate the line-averaged density $\bar n_e = \frac{1}{L} \int\limits_L n_e(l) \mathrm{d}l$ from the detected phase shift between the reference and mixer signals.
omega_carrier = 2*np.pi*71e9 # 71 GHz microwave generator
a = 0.085 # limiter radius
L = 2*a # central plasma chord estimate
prop_const = constants.elementary_charge**2 / (
2*omega_carrier* constants.speed_of_light*constants.epsilon_0*constants.m_e)
if is_plasma:
ne_lav = dphase / prop_const / L
# only save every 100-th point as there is not much useful signal above 2 MHz
save_sl = slice(0, t_plasma_end+5, 100)
if is_plasma:
ne_lav.loc[save_sl].to_csv('ne_lav.csv', header=None)
if is_plasma:
fig = plt.figure(figsize=(6, 4.5), dpi=300)
(ne_lav.loc[save_sl] / 1e19).plot()
for t in (t_plasma_start, t_plasma_end):
plt.axvline(t, color='k', linestyle='--')
plt.gca().set(xlabel='time [ms]', ylim=(0,None),
ylabel='$\\bar n_e$ [10$^{19}$ m$^{-3}$]')
plt.savefig('icon-fig.png')
if is_plasma:
ne_lav_plasma = ne_lav.loc[t_plasma_start:t_plasma_end]
for m in ('mean', 'max'):
v = getattr(ne_lav_plasma, m)()
with open(f'ne_lav_{m}', 'w') as f:
f.write(f'{v:.3e}')