10:50:42 #38902 Discharge/PrepareDischargeEnv@SHM: Command Line Request: UPP 10:50:42 #38902 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 10:50:42 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.40 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:50:44 #38902 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 10:50:44 #38902 /GetReadyTheDischarge: Going with gas pressure 6 10:50:44 #38902 /GetReadyTheDischarge: Going with gas type H 10:50:44 #38902 /GetReadyTheDischarge: Discharge with Hydrogen request 10:50:44 #38902 /GetReadyTheDischarge: Discharge with 6 mPa request 10:50:44 #38902 /GetReadyTheDischarge: Discharge with Bt CW request 10:50:45 #38902 /GetReadyTheDischarge: Going with CD_orientation CW 10:50:45 #38902 /GetReadyTheDischarge: Discharge with CD CW request 10:50:46 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.935 Pa, Gas: H2, GasValve: 20.43 V 10:50:49 #38902 /VacuumLog: Chamber: 1.04 mPa, 37.40 C, ForVacuum: 0.94 Pa, Gas: H2, GasValve: 21.44 V 10:50:52 #38902 /GetReadyTheDischarge: Bt capacitor charging started 10:50:53 #38902 /VacuumLog: Chamber: 1.49 mPa, 37.50 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 22.85 V 10:50:56 #38902 /GetReadyTheDischarge: Cd capacitor charging started 10:50:56 #38902 /ChargingResistorsAllOFF: Diving into .. 10:50:56 #38902 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 10:50:56 #38902 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 10:50:56 #38902 /GetReadyTheDischarge: Charging ... HV=-12 V 10:50:57 #38902 /GetReadyTheDischarge: Charging ... HV=-12 V Gas: H2, GasValve: 23.68 V 10:50:57 #38902 /GetReadyTheDischarge: Charging ... HV=-12 V 10:50:58 #38902 /GetReadyTheDischarge: Charging ... HV=17 V 10:50:58 #38902 /GetReadyTheDischarge: Charging ... HV=17 V 10:50:59 #38902 /GetReadyTheDischarge: Charging ... HV=16 V 10:50:59 #38902 /GetReadyTheDischarge: Charging ... HV=65 V 10:50:59 #38902 /GetReadyTheDischarge: Charging ... HV=65 V 10:51:00 #38902 /GetReadyTheDischarge: Charging ... HV=112 V 10:51:00 #38902 /GetReadyTheDischarge: Charging ... HV=112 V 10:51:01 #38902 /GetReadyTheDischarge: Charging ... HV=158 V 10:51:01 #38902 /GetReadyTheDischarge: Charging ... HV=158 V 10:51:02 #38902 /GetReadyTheDischarge: Charging ... HV=158 V 10:51:02 #38902 /GetReadyTheDischarge: Charging ... HV=203 V 10:51:03 #38902 /GetReadyTheDischarge: Charging ... HV=203 V 10:51:03 #38902 /GetReadyTheDischarge: Charging ... HV=249 V 10:51:03 #38902 /GetReadyTheDischarge: Charging ... HV=249 V 10:51:04 #38902 /GetReadyTheDischarge: Charging ... HV=249 V 10:51:04 #38902 /GetReadyTheDischarge: Charging ... HV=292 V 10:51:05 #38902 /GetReadyTheDischarge: Charging ... HV=292 V 10:51:05 #38902 /GetReadyTheDischarge: Charging ... HV=335 V 10:51:06 #38902 /GetReadyTheDischarge: Charging ... HV=335 V 10:51:06 #38902 /GetReadyTheDischarge: Charging ... HV=375 V 10:51:06 #38902 /GetReadyTheDischarge: Charging ... HV=375 V 10:51:07 #38902 /GetReadyTheDischarge: Charging ... HV=375 V 10:51:07 #38902 /GetReadyTheDischarge: Charging ... HV=413 V 10:51:08 #38902 /VacuumLog: Chamber: 6.51 mPa, 37.40 C, ForVacuum: 2.45 Pa, Gas: H2, GasValve: 24.12 V 10:51:08 #38902 /GetReadyTheDischarge: Charging ... HV=413 V 10:51:08 #38902 /GetReadyTheDischarge: Charging ... HV=452 V 10:51:08 #38902 /GetReadyTheDischarge: Cd capacitor charging finished @ 452 V 10:51:09 #38902 /GetReadyTheDischarge: Charging ... HV=452 V 10:51:09 #38902 /GetReadyTheDischarge: Charging ... HV=452 V 10:51:10 #38902 /GetReadyTheDischarge: Charging ... HV=489 V 10:51:10 #38902 /GetReadyTheDischarge: Charging ... HV=489 V 10:51:10 #38902 /GetReadyTheDischarge: Charging ... HV=529 V 10:51:11 #38902 /GetReadyTheDischarge: Charging ... HV=529 V 10:51:11 #38902 /GetReadyTheDischarge: Charging ... HV=529 V 10:51:11 #38902 /VacuumLog: Chamber: 7.75 mPa, 37.40 C, ForVacuum: 2.55 Pa, Gas: H2, GasValve: 24.12 V 10:51:12 #38902 /GetReadyTheDischarge: Charging ... HV=568 V 10:51:12 #38902 /GetReadyTheDischarge: Charging ... HV=568 V 10:51:13 #38902 /GetReadyTheDischarge: Charging ... HV=605 V 10:51:13 #38902 /GetReadyTheDischarge: Charging ... HV=605 V 10:51:13 #38902 /GetReadyTheDischarge: Charging ... HV=605 V 10:51:14 #38902 /GetReadyTheDischarge: Charging ... HV=640 V 10:51:14 #38902 /GetReadyTheDischarge: Charging ... HV=640 V 10:51:15 #38902 /GetReadyTheDischarge: Charging ... HV=677 V 10:51:15 #38902 /GetReadyTheDischarge: Charging ... HV=677 V Gas: H2, GasValve: 24.12 V 10:51:16 #38902 /GetReadyTheDischarge: Charging ... HV=677 V 10:51:16 #38902 /GetReadyTheDischarge: Charging ... HV=712 V 10:51:16 #38902 /GetReadyTheDischarge: Charging ... HV=712 V 10:51:17 #38902 /GetReadyTheDischarge: Charging ... HV=745 V 10:51:17 #38902 /GetReadyTheDischarge: Charging ... HV=745 V 10:51:18 #38902 /GetReadyTheDischarge: Charging ... HV=745 V 10:51:18 #38902 /GetReadyTheDischarge: Charging ... HV=776 V 10:51:19 #38902 /GetReadyTheDischarge: Charging ... HV=776 V 10:51:19 #38902 /GetReadyTheDischarge: Charging ... HV=807 V Gas: H2, GasValve: 24.12 V 10:51:19 #38902 /ChargingResistorsAllON: Diving into .. 10:51:20 #38902 /GetReadyTheDischarge: Bt capacitor charging finished @ 807 V 10:51:20 #38902 /ChargingResistorsAllON: Diving into .. 10:51:20 #38902 /GetReadyTheDischarge: Ascending from .. 10:51:20 #38902 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 10:51:22 #38902 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:51:22 #38902 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:51:22 #38902 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 10:51:22 #38902 /VacuumLog: Chamber: 9.62 mPa, 37.40 C, ForVacuum: 3.15 Pa, Gas: H2, GasValve: 24.12 V 10:51:26 #38902 /VacuumLog: Chamber: 9.78 mPa, 37.50 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 24.12 V 10:51:30 #38902 /VacuumLog: Chamber: 9.89 mPa, 37.40 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 24.12 V 10:51:33 #38902 /Trigger: Going through .. 10:51:33 #38902 Discharge/HWTrigger: Going through .. 10:51:33 #38902 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 10:51:33 #38902 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 10:51:33 #38902 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 10:51:33 #38902 /VacuumLog: Chamber: 9.99 mPa, 37.40 C, ForVacuum: 3.25 Pa, Gas: H2, GasValve: 24.12 V 10:51:37 #38902 /VacuumLog: Chamber: 9.91 mPa, 37.40 C, ForVacuum: 3.1 Pa, Gas: H2, GasValve: 24.12 V 10:51:37 #38902 /ChargingResistorsAllON: Diving into .. 10:51:40 #38902 /SecurePostDischargeState: Going through .. 10:51:40 #38902 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 10:51:41 #38902 /VacuumLog: Chamber: 1.31 mPa, 37.50 C, ForVacuum: 2.4 Pa, Gas: NULL, GasValve: 0.00 V 10:51:44 #38902 /VacuumLog: Chamber: 1.03 mPa, 37.50 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 10:51:45 #38902 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 10:51:48 #38902 /VacuumLog: Chamber: 0.99 mPa, 37.50 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 10:51:52 #38902 /VacuumLog: Chamber: 0.97 mPa, 37.40 C, ForVacuum: 0.905 Pa, Gas: NULL, GasValve: 0.00 V 10:51:55 #38902 /VacuumLog: Chamber: 0.96 mPa, 37.50 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 10:51:59 #38902 /VacuumLog: Chamber: 0.95 mPa, 37.50 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 10:52:02 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.92 Pa, Gas: NULL, GasValve: 0.00 V 10:52:06 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 10:52:10 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 10:52:13 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 10:52:16 #38902 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 10:52:17 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 10:52:21 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:52:24 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.40 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:52:28 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.40 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:52:29 #38902 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 10:52:32 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.40 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:52:35 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:52:39 #38902 /DischargeFunction: General Calling FinalDischargeOperations 10:52:39 #38902 /VacuumLog: Chamber: 0.94 mPa, 37.40 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V