11:10:17 #38906 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:10:17 #38907 Discharge/PrepareDischargeEnv@SHM: Command Line Request: UPP 11:10:17 #38907 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:10:19 #38907 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:10:19 #38907 /GetReadyTheDischarge: Going with gas pressure 6 11:10:19 #38907 /GetReadyTheDischarge: Going with gas type H 11:10:19 #38907 /GetReadyTheDischarge: Discharge with Hydrogen requ11:10:19 #38907 /11:10:19 #38907 /GetReadyTheDischarge: Discharge with 6 mPa request GetReadyTheDischarge: Discharge with Bt CW request 11:10:20 #38907 /GetReadyTheDischarge: Going with CD_orientation CW 11:10:20 #38907 /GetReadyTheDischarge: Discharge with CD CW request 11:10:21 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: H2, GasValve: 20.43 V 11:10:24 #38907 /VacuumLog: Chamber: 0.99 mPa, 36.60 C, ForVacuum: 0.935 Pa, Gas: H2, GasValve: 21.45 V 11:10:27 #38907 /GetReadyTheDischarge: Bt capacitor charging started 11:10:28 #38907 /VacuumLog: Chamber: 1.39 mPa, 36.50 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 22.42 V 11:10:31 #38907 /GetReadyTheDischarge: Cd capacitor charging started 11:10:31 #38907 /ChargingResistorsAllOFF: Diving into .. 11:10:31 #38907 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 11:10:31 #38907 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 11:10:31 #38907 /GetReadyTheDischarge: Charging ... HV=-13 V 11:10:32 #38907 /GetReadyTheDischarge: Charging ... HV=-13 V Gas: H2, GasValve: 22.42 V 11:10:32 #38907 /GetReadyTheDischarge: Charging ... HV=4 V 11:10:33 #38907 /GetReadyTheDischarge: Charging ... HV=4 V 11:10:33 #38907 /GetReadyTheDischarge: Charging ... HV=4 V 11:10:34 #38907 /GetReadyTheDischarge: Charging ... HV=17 V 11:10:34 #38907 /GetReadyTheDischarge: Charging ... HV=51 V 11:10:34 #38907 /GetReadyTheDischarge: Charging ... HV=99 V 11:10:35 #38907 /GetReadyTheDischarge: Charging ... HV=99 V 11:10:35 #38907 /GetReadyTheDischarge: Charging ... HV=99 V 11:10:36 #38907 /GetReadyTheDischarge: Charging ... HV=145 V 11:10:36 #38907 /GetReadyTheDischarge: Charging ... HV=145 V 11:10:37 #38907 /GetReadyTheDischarge: Charging ... HV=190 V 11:10:37 #38907 /GetReadyTheDischarge: Charging ... HV=190 V 11:10:37 #38907 /GetReadyTheDischarge: Charging ... HV=190 V 11:10:38 #38907 /GetReadyTheDischarge: Charging ... HV=237 V 11:10:38 #38907 /GetReadyTheDischarge: Charging ... HV=237 V 11:10:39 #38907 /GetReadyTheDischarge: Charging ... HV=281 V 11:10:39 #38907 /GetReadyTheDischarge: Charging ... HV=281 V 11:10:40 #38907 /GetReadyTheDischarge: Charging ... HV=325 V 11:10:40 #38907 /GetReadyTheDischarge: Charging ... HV=325 V 11:10:41 #38907 /GetReadyTheDischarge: Charging ... HV=325 V 11:10:41 #38907 /GetReadyTheDischarge: Charging ... HV=365 V 11:10:41 #38907 /GetReadyTheDischarge: Charging ... HV=365 V 11:10:42 #38907 /GetReadyTheDischarge: Charging ... HV=403 V 11:10:42 #38907 /GetReadyTheDischarge: Charging ... HV=403 V 11:10:42 #38907 /VacuumLog: Chamber: 1.76 mPa, 36.50 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 22.42 V 11:10:43 #38907 /GetReadyTheDischarge: Charging ... HV=403 V 11:10:43 #38907 /GetReadyTheDischarge: Charging ... HV=442 V 11:10:43 #38907 /GetReadyTheDischarge: Cd slow PowSup 11:10:43 #38907 /ChargingResistorsAllON: Diving into .. 11:10:44 #38907 /GetReadyTheDischarge: Charging ... HV=442 V 11:10:44 #38907 /GetReadyTheDischarge: Charging ... HV=478 V 11:10:44 #38907 /GetReadyTheDischarge: Cd capacitor charging finished @ 478 V 11:10:44 #38907 /GetReadyTheDischarge: Bt boost PowSup 11:10:44 #38907 /ChargingResistorsAllOFF: Diving into .. 11:10:45 #38907 /GetReadyTheDischarge: Charging ... HV=478 V 11:10:45 #38907 /GetReadyTheDischarge: Charging ... HV=489 V 11:10:46 #38907 /GetReadyTheDischarge: Charging ... HV=489 V 11:10:46 #38907 /VacuumLog: Chamber: 1.85 mPa, 36.40 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 22.42 V 11:10:46 #38907 /GetReadyTheDischarge: Charging ... HV=17 V 11:10:47 #38907 /GetReadyTheDischarge: Charging ... HV=520 V 11:10:47 #38907 /GetReadyTheDischarge: Charging ... HV=520 V 11:10:47 #38907 /GetReadyTheDischarge: Charging ... HV=559 V 11:10:48 #38907 /GetReadyTheDischarge: Charging ... HV=559 V 11:10:48 #38907 /GetReadyTheDischarge: Charging ... HV=596 V 11:10:49 #38907 /GetReadyTheDischarge: Charging ... HV=596 V 11:10:49 #38907 /GetReadyTheDischarge: Charging ... HV=596 V 11:10:50 #38907 /GetReadyTheDischarge: Charging ... HV=631 V 11:10:50 #38907 /VacuumLog: Chamber: 1.88 mPa, 36.40 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 22.42 V 11:10:50 #38907 /GetReadyTheDischarge: Charging ... HV=631 V 11:10:50 #38907 /GetReadyTheDischarge: Charging ... HV=631 V 11:10:51 #38907 /GetReadyTheDischarge: Charging ... HV=667 V 11:10:51 #38907 /GetReadyTheDischarge: Charging ... HV=667 V 11:10:52 #38907 /GetReadyTheDischarge: Charging ... HV=702 V 11:10:52 #38907 /GetReadyTheDischarge: Charging ... HV=702 V 11:10:52 #38907 /GetReadyTheDischarge: Charging ... HV=702 V 11:10:53 #38907 /GetReadyTheDischarge: Charging ... HV=735 V 11:10:53 #38907 /GetReadyTheDischarge: Charging ... HV=735 V Gas: H2, GasValve: 22.42 V 11:10:54 #38907 /GetReadyTheDischarge: Charging ... HV=766 V 11:10:54 #38907 /GetReadyTheDischarge: Charging ... HV=766 V 11:10:55 #38907 /GetReadyTheDischarge: Charging ... HV=766 V 11:10:55 #38907 /GetReadyTheDischarge: Charging ... HV=797 V 11:10:55 #38907 /GetReadyTheDischarge: Bt slow PowSup 11:10:55 #38907 /ChargingResistorsAllON: Diving into .. 11:10:56 #38907 /GetReadyTheDischarge: Charging ... HV=797 V 11:10:56 #38907 /GetReadyTheDischarge: Charging ... HV=827 V 11:10:56 #38907 /ChargingResistorsAllON: Diving into .. 11:10:57 #38907 /GetReadyTheDischarge: Bt capacitor charging finished @ 827 V 11:10:57 #38907 /ChargingResistorsAllON: Diving into .. .25 Pa, Gas: H2, GasValve: 22.42 V 11:10:57 #38907 /GetReadyTheDischarge: Ascending from .. 11:10:57 #38907 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:10:59 #38907 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:10:59 #38907 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:11:01 #38907 /VacuumLog: Chamber: 2.18 mPa, 36.50 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 22.42 V 11:11:04 #38907 /VacuumLog: Chamber: 2.23 mPa, 36.50 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 22.42 V 11:11:08 #38907 /VacuumLog: Chamber: 2.35 mPa, 36.40 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 22.42 V 11:11:10 #38907 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:11:12 #38907 /VacuumLog: Chamber: 2.41 mPa, 36.30 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 22.42 V 11:11:15 #38907 /VacuumLog: Chamber: 2.46 mPa, 36.50 C, ForVacuum: 1.4 Pa, Gas: H2, GasValve: 22.42 V 11:11:19 #38907 /VacuumLog: Chamber: 2.48 mPa, 36.50 C, ForVacuum: 1.4 Pa, Gas: H2, GasValve: 22.42 V 11:11:20 #38907 /Trigger: Going through .. 11:11:20 #38907 Discharge/HWTrigger: Going through .. 11:11:20 #38907 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 11:11:20 #38907 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 11:11:20 #38907 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 11:11:22 #38907 /VacuumLog: Chamber: 2.48 mPa, 36.50 C, ForVacuum: 1.4 Pa, Gas: H2, GasValve: 22.42 V 11:11:25 #38907 /ChargingResistorsAllON: Diving into .. 11:11:26 #38907 /VacuumLog: Chamber: 2.40 mPa, 36.50 C, ForVacuum: 1.4 Pa, Gas: H2, GasValve: 0.00 V 11:11:27 #38907 /SecurePostDischargeState: Going through .. 11:11:27 #38907 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:11:29 #38907 /VacuumLog: Chamber: 0.96 mPa, 36.50 C, ForVacuum: 1.1 Pa, Gas: NULL, GasValve: 0.00 V 11:11:32 #38907 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:11:33 #38907 /VacuumLog: Chamber: 0.94 mPa, 36.50 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 11:11:37 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.60 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 11:11:40 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.60 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 11:11:44 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 11:11:48 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:11:51 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:11:55 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:11:58 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.60 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:12:00 #38907 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:12:02 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:12:06 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:12:09 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:12:13 #38907 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 11:12:13 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:12:17 #38907 /VacuumLog: Chamber: 0.93 mPa, 36.50 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:12:19 #38907 /DischargeFunction: General Calling FinalDischargeOperations