11:48:18 #38934 Discharge/PrepareDischargeEnv@SHM: Command Line Request: EDU 11:48:18 #38934 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:48:20 #38934 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:48:20 #38934 /GetReadyTheDischarge: Going with gas pressure 10 11:48:20 #38934 /GetReadyTheDischarge: Going with gas type H 11:48:20 #38934 /GetReadyTheDischarge: Discharge with Hydrogen request 11:48:20 #38934 /GetReadyTheDischarge: Discharge with 10 mPa request 11:48:21 #38934 /VacuumLog: Chamber: 1.56 mPa, 30.20 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 0.00 V ischarge: Going with CD_orientation CW 11:48:21 #38934 /GetReadyTheDischarge: Discharge with CD CW request 11:48:25 #38934 /VacuumLog: Chamber: 1.56 mPa, 30.20 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 21.87 V 11:48:27 #38934 /GetReadyTheDischarge: Bt capacitor charging started 11:48:28 #38934 /VacuumLog: Chamber: 1.56 mPa, 30.20 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 24.40 V 11:48:32 #38934 /GetReadyTheDischarge: Cd capacitor charging started 11:48:32 #38934 /ChargingResistorsAllOFF: Diving into .. 11:48:32 #38934 /GetReadyTheDischarge: U_Bt: 220, Hrana: 98 11:48:32 #38934 /GetReadyTheDischarge: U_Et: 220, Hrana: 98 11:48:32 #38934 /GetReadyTheDischarge: Charging ... HV=-10 V 11:48:33 #38934 /GetReadyTheDischarge: Charging ... HV=-10 V 11:48:33 #38934 /GetReadyTheDischarge: Charging ... HV=7 V 11:48:34 #38934 /GetReadyTheDischarge: Charging ... HV=7 V 11:48:34 #38934 /GetReadyTheDischarge: Charging ... HV=7 V 11:48:34 #38934 /GetReadyTheDischarge: Charging ... HV=54 V 11:48:35 #38934 /GetReadyTheDischarge: Charging ... HV=54 V 11:48:35 #38934 /GetReadyTheDischarge: Charging ... HV=102 V 11:48:36 #38934 /VacuumLog: Chamber: 13.00 mPa, 30.20 C, ForVacuum: 2.45 Pa, Gas: H2, GasValve: 26.87 V 11:48:36 #38934 /GetReadyTheDischarge: Charging ... HV=102 V 11:48:36 #38934 /GetReadyTheDischarge: Charging ... HV=148 V 11:48:37 #38934 /GetReadyTheDischarge: Charging ... HV=148 V 11:48:37 #38934 /GetReadyTheDischarge: Charging ... HV=148 V 11:48:37 #38934 /GetReadyTheDischarge: Charging ... HV=193 V 11:48:38 #38934 /GetReadyTheDischarge: Charging ... HV=193 V 11:48:38 #38934 /GetReadyTheDischarge: Charging ... HV=239 V 11:48:39 #38934 /GetReadyTheDischarge: Bt capacitor charging finished @ 239 V 11:48:39 #38934 /ChargingResistorsAllON: Diving into .. 11:48:39 #38934 /GetReadyTheDischarge: Cd capacitor charging finished @ 239 V 11:48:39 #38934 /VacuumLog: Chamber: 23.20 mPa, 30.20 C, ForVacuum: 4.35 Pa, Gas: H2, GasValve: 26.87 V 11:48:39 #38934 /ChargingResistorsAllON: Diving into .. 11:48:40 #38934 /GetReadyTheDischarge: Ascending from .. 11:48:40 #38934 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:48:41 #38934 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:48:41 #38934 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:48:41 #38934 TektrMSO64-a/LogTheDeviceAction: The TunnelProbe action on stage with Arming 11:48:41 #38934 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_JCetal action on stage with Arming 11:48:43 #38934 /VacuumLog: Chamber: 29.80 mPa, 30.10 C, ForVacuum: 5.75 Pa, Gas: H2, GasValve: 26.87 V 11:48:43 #38934 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:48:46 #38934 /VacuumLog: Chamber: 31.50 mPa, 30.10 C, ForVacuum: 6.2 Pa, Gas: H2, GasValve: 26.87 V 11:48:50 #38934 /VacuumLog: Chamber: 32.80 mPa, 30.20 C, ForVacuum: 6.4 Pa, Gas: H2, GasValve: 26.87 V 11:48:54 #38934 /VacuumLog: Chamber: 33.90 mPa, 30.20 C, ForVacuum: 6.5 Pa, Gas: H2, GasValve: 26.87 V 11:48:54 #38934 /Trigger: Going through .. 11:48:54 #38934 Discharge/HWTrigger: Going through .. 11:48:54 #38934 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 11:48:54 #38934 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 11:48:54 #38934 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 11:48:57 #38934 /VacuumLog: Chamber: 34.80 mPa, 30.20 C, ForVacuum: 6.6 Pa, Gas: H2, GasValve: 26.87 V 11:49:00 #38934 /ChargingResistorsAllON: Diving into .. 11:49:01 #38934 /VacuumLog: Chamber: 35.90 mPa, 30.20 C, ForVacuum: 6.65 Pa, Gas: H2, GasValve: 0.00 V 11:49:02 #38934 /SecurePostDischargeState: Going through .. 11:49:02 #38934 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:49:04 #38934 /VacuumLog: Chamber: 1.77 mPa, 30.20 C, ForVacuum: 2.8 Pa, Gas: NULL, GasValve: 0.00 V 11:49:08 #38934 /VacuumLog: Chamber: 1.64 mPa, 30.20 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 11:49:10 #38934 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:49:11 #38934 Papouch-St/RawDataAcquiring: Papouch-St: Start of acquiring 11:49:12 #38934 /VacuumLog: Chamber: 1.59 mPa, 30.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 11:49:15 #38934 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 11:49:15 #38934 /VacuumLog: Chamber: 1.55 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:16 #38934 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 11:49:18 #38934 Papouch-St/RawDataAcquiring: Papouch-St: End of acquiring 11:49:19 #38934 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:49:19 #38934 /VacuumLog: Chamber: 1.53 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:23 #38934 /VacuumLog: Chamber: 1.52 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:26 #38934 /VacuumLog: Chamber: 1.51 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:30 #38934 /VacuumLog: Chamber: 1.50 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:34 #38934 /VacuumLog: Chamber: 1.49 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:37 #38934 /VacuumLog: Chamber: 1.49 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:41 #38934 /VacuumLog: Chamber: 1.48 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:45 #38934 /VacuumLog: Chamber: 1.48 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:48 #38934 /VacuumLog: Chamber: 1.48 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:52 #38934 /VacuumLog: Chamber: 1.47 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:52 #38934 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 11:49:56 #38934 /VacuumLog: Chamber: 1.47 mPa, 30.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 11:49:56 #38934 /DischargeFunction: General Calling FinalDischargeOperations