18:17:01 #38973 Discharge/PrepareDischargeEnv@SHM: Command Line Request: EDU 18:17:02 #38973 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 18:17:03 #38973 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 18:17:04 #38973 /GetReadyTheDischarge: Going with gas pressure 10 18:17:04 #38973 /GetReadyTheDischarge: Going with gas type H 18:17:04 #38973 /GetReadyTheDischarge: Discharge with Hydrogen request 18:17:04 #38973 /GetReadyTheDischarge: Discharge with 10 mPa request 18:17:04 #38973 /GetReadyTheDischarge: Discharge with Bt CW request 18:17:04 #38973 /GetReadyTheDischarge: Going with CD_orientation CW 18:17:04 #38973 /GetReadyTheDischarge: Discharge with CD CW request 18:17:05 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 21.14 V 18:17:08 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 22.97 V 18:17:11 #38973 /GetReadyTheDischarge: Bt capacitor charging started 18:17:12 #38973 /VacuumLog: Chamber: 1.58 mPa, 37.00 C, ForVacuum: 1.1 Pa, Gas: H2, GasValve: 24.75 V 18:17:15 #38973 /GetReadyTheDischarge: Cd capacitor charging started 18:17:15 #38973 /ChargingResistorsAllOFF: Diving into .. 18:17:15 #38973 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 18:17:15 #38973 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 18:17:16 #38973 /GetReadyTheDischarge: Charging ... HV=-11 V 18:17:16 #38973 /GetReadyTheDischarge: Charging ... HV=-7 V 18:17:17 #38973 /GetReadyTheDischarge: Charging ... HV=-7 V 18:17:17 #38973 /GetReadyTheDischarge: Charging ... HV=26 V 18:17:17 #38973 /GetReadyTheDischarge: Charging ... HV=26 V 18:17:18 #38973 /GetReadyTheDischarge: Charging ... HV=0 V 18:17:18 #38973 /GetReadyTheDischarge: Charging ... HV=75 V 18:17:19 #38973 /GetReadyTheDischarge: Charging ... HV=75 V 18:17:19 #38973 /GetReadyTheDischarge: Charging ... HV=121 V 18:17:20 #38973 /GetReadyTheDischarge: Charging ... HV=121 V 18:17:20 #38973 /GetReadyTheDischarge: Charging ... HV=121 V 18:17:20 #38973 /GetReadyTheDischarge: Charging ... HV=167 V 18:17:21 #38973 /GetReadyTheDischarge: Charging ... HV=167 V 18:17:21 #38973 /GetReadyTheDischarge: Charging ... HV=0 V 18:17:22 #38973 /GetReadyTheDischarge: Charging ... HV=214 V 18:17:22 #38973 /GetReadyTheDischarge: Charging ... HV=259 V 18:17:23 #38973 /GetReadyTheDischarge: Charging ... HV=259 V 18:17:23 #38973 /VacuumLog: Chamber: 17.00 mPa, 37.10 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 26.22 V 18:17:23 #38973 /GetReadyTheDischarge: Charging ... HV=259 V 18:17:24 #38973 /GetReadyTheDischarge: Charging ... HV=304 V 18:17:24 #38973 /GetReadyTheDischarge: Charging ... HV=304 V 18:17:24 #38973 /GetReadyTheDischarge: Charging ... HV=346 V 18:17:25 #38973 /GetReadyTheDischarge: Charging ... HV=346 V 18:17:25 #38973 /GetReadyTheDischarge: Charging ... HV=346 V 18:17:26 #38973 /GetReadyTheDischarge: Charging ... HV=385 V 18:17:26 #38973 /GetReadyTheDischarge: Charging ... HV=385 V 18:17:27 #38973 /GetReadyTheDischarge: Charging ... HV=423 V 18:17:27 #38973 /VacuumLog: Chamber: 18.10 mPa, 37.00 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 26.22 V 18:17:27 #38973 /GetReadyTheDischarge: Charging ... HV=423 V 18:17:27 #38973 /GetReadyTheDischarge: Charging ... HV=423 V 18:17:28 #38973 /GetReadyTheDischarge: Charging ... HV=464 V 18:17:28 #38973 /GetReadyTheDischarge: Charging ... HV=464 V 18:17:29 #38973 /GetReadyTheDischarge: Charging ... HV=500 V 18:17:29 #38973 /GetReadyTheDischarge: Cd capacitor charging finished @ 500 V 18:17:29 #38973 /GetReadyTheDischarge: Charging ... HV=500 V 18:17:30 #38973 /GetReadyTheDischarge: Charging ... HV=500 V 18:17:30 #38973 /GetReadyTheDischarge: Charging ... HV=537 V 18:17:31 #38973 /GetReadyTheDischarge: Charging ... HV=537 V , Gas: H2, GasValve: 26.22 V 18:17:31 #38973 /GetReadyTheDischarge: Charging ... HV=576 V 18:17:31 #38973 /GetReadyTheDischarge: Charging ... HV=576 V 18:17:32 #38973 /GetReadyTheDischarge: Charging ... HV=576 V 18:17:32 #38973 /GetReadyTheDischarge: Charging ... HV=613 V 18:17:33 #38973 /GetReadyTheDischarge: Charging ... HV=613 V 18:17:33 #38973 /GetReadyTheDischarge: Charging ... HV=647 V 18:17:34 #38973 /GetReadyTheDischarge: Charging ... HV=647 V 18:17:34 #38973 /GetReadyTheDischarge: Charging ... HV=647 V 18:17:34 #38973 /GetReadyTheDischarge: Charging ... HV=686 V , Gas: H2, GasValve: 26.22 V 18:17:35 #38973 /GetReadyTheDischarge: Charging ... HV=686 V 18:17:35 #38973 /GetReadyTheDischarge: Charging ... HV=720 V 18:17:36 #38973 /GetReadyTheDischarge: Charging ... HV=720 V 18:17:36 #38973 /GetReadyTheDischarge: Charging ... HV=720 V 18:17:36 #38973 /GetReadyTheDischarge: Charging ... HV=752 V 18:17:37 #38973 /GetReadyTheDischarge: Charging ... HV=752 V 18:17:37 #38973 /GetReadyTheDischarge: Charging ... HV=784 V 18:17:38 #38973 /GetReadyTheDischarge: Charging ... HV=784 V 18:17:38 #38973 /GetReadyTheDischarge: Charging ... HV=784 V 18:17:39 #38973 /GetReadyTheDischarge: Charging ... HV=815 V 18:17:39 #38973 /ChargingResistorsAllON: Diving into .. 18:17:39 #38973 /GetReadyTheDischarge: Bt capacitor charging finished @ 815 V 18:17:40 #38973 /ChargingResistorsAllON: Diving into .. 18:17:40 #38973 /GetReadyTheDischarge: Ascending from .. 18:17:40 #38973 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 18:17:41 #38973 /VacuumLog: Chamber: 20.10 mPa, 37.10 C, ForVacuum: 5.05 Pa, Gas: H2, GasValve: 26.22 V 18:17:42 #38973 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:17:42 #38973 TektrMSO64-a/LogTheDeviceAction: The TunnelProbe action on stage with Arming 18:17:42 #38973 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:17:42 #38973 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_MT action on stage with Arming 18:17:45 #38973 /VacuumLog: Chamber: 20.50 mPa, 37.00 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 26.22 V 18:17:47 #38973 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 18:17:49 #38973 /VacuumLog: Chamber: 20.80 mPa, 37.00 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 26.22 V 18:17:52 #38973 /VacuumLog: Chamber: 21.20 mPa, 37.00 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 26.22 V 18:17:56 #38973 /VacuumLog: Chamber: 21.50 mPa, 37.00 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 26.22 V 18:17:58 #38973 /Trigger: Going through .. 18:17:58 #38973 Discharge/HWTrigger: Going through .. 18:17:58 #38973 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 18:17:58 #38973 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 18:17:58 #38973 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 18:18:00 #38973 /VacuumLog: Chamber: 21.80 mPa, 37.00 C, ForVacuum: 5.3 Pa, Gas: H2, GasValve: 26.22 V 18:18:02 #38973 /ChargingResistorsAllON: Diving into .. 18:18:03 #38973 /VacuumLog: Chamber: 22.40 mPa, 37.00 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 0.00 V 18:18:05 #38973 /SecurePostDischargeState: Going through .. 18:18:05 #38973 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 18:18:07 #38973 /VacuumLog: Chamber: 1.16 mPa, 37.10 C, ForVacuum: 2.35 Pa, Gas: NULL, GasValve: 0.00 V 18:18:10 #38973 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 18:18:10 #38973 /VacuumLog: Chamber: 1.03 mPa, 37.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:18:13 #38973 Papouch-St/RawDataAcquiring: Papouch-St: Start of acquiring 18:18:13 #38973 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 18:18:14 #38973 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 18:18:14 #38973 /VacuumLog: Chamber: 0.97 mPa, 37.20 C, ForVacuum: 0.99 Pa, Gas: NULL, GasValve: 0.00 V 18:18:18 #38973 /VacuumLog: Chamber: 0.94 mPa, 37.10 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V 18:18:20 #38973 Papouch-St/RawDataAcquiring: Papouch-St: End of acquiring 18:18:21 #38973 /VacuumLog: Chamber: 0.92 mPa, 37.10 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 18:18:25 #38973 /VacuumLog: Chamber: 0.90 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:29 #38973 /VacuumLog: Chamber: 0.89 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:32 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:36 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:40 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:43 #38973 /VacuumLog: Chamber: 0.87 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:47 #38973 /VacuumLog: Chamber: 0.87 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:48 #38973 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 18:18:51 #38973 /VacuumLog: Chamber: 0.87 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:54 #38973 /VacuumLog: Chamber: 0.87 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:18:58 #38973 /VacuumLog: Chamber: 0.87 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:02 #38973 /VacuumLog: Chamber: 0.87 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:05 #38973 /VacuumLog: Chamber: 0.87 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:09 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:12 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:16 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:20 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:23 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:27 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:31 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:34 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:38 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:41 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:45 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:49 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:51 #38973 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 18:19:52 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:56 #38973 /VacuumLog: Chamber: 0.88 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:19:57 #38973 /DischargeFunction: General Calling FinalDischargeOperations 18:20:00 #38973 /VacuumLog: Chamber: 0.89 mPa, 37.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 18:20:03 #38973 /VacuumLog: Chamber: 0.89 mPa, 37.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V