16:37:23 #38979 /VacuumLog: Chamber: 0.91 mPa, 31.40 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 16:37:24 #38980 Discharge/PrepareDischargeEnv@SHM: Command Line Request: RE session preparation 16:37:24 #38980 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:37:25 #38980 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:37:26 #38980 /GetReadyTheDischarge: Going with gas pressure 10 16:37:26 #38980 /GetReadyTheDischarge: Going with gas type H 16:37:26 #38980 /GetReadyTheDischarge: Discharge with Hydrogen request 16:37:26 #38980 /GetReadyTheDischarge: Discharge with 10 mPa request 16:37:26 #38980 /GetReadyTheDischarge: Discharge with Bt CW request 16:37:26 #38980 /GetReadyTheDischarge: Going with CD_orientation CW 16:37:26 #38980 /GetReadyTheDischarge: Discharge with CD CW request 16:37:27 #38980 /GetReadyTheDischarge: It is a dummy discharge - without Charger action 16:37:27 #38980 /VacuumLog: Chamber: 0.91 mPa, 31.50 C, ForVacuum: 0.945 Pa, Gas: H2, GasValve: 21.14 V 16:37:30 #38980 /VacuumLog: Chamber: 0.91 mPa, 31.50 C, ForVacuum: 0.945 Pa, Gas: H2, GasValve: 22.95 V 16:37:32 #38980 /GetReadyTheDischarge: Ascending from .. 16:37:34 #38980 /VacuumLog: Chamber: 0.94 mPa, 31.50 C, ForVacuum: 0.945 Pa, Gas: H2, GasValve: 24.77 V 16:37:38 #38980 /VacuumLog: Chamber: 6.02 mPa, 31.50 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 26.94 V 16:37:41 #38980 /VacuumLog: Chamber: 16.80 mPa, 31.40 C, ForVacuum: 3.1 Pa, Gas: H2, GasValve: 26.29 V 16:37:42 #38980 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:37:44 #38980 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:37:44 #38980 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:37:45 #38980 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:37:45 #38980 /VacuumLog: Chamber: 18.80 mPa, 31.50 C, ForVacuum: 4.45 Pa, Gas: H2, GasValve: 26.29 V 16:37:49 #38980 /VacuumLog: Chamber: 19.70 mPa, 31.40 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 26.29 V 16:37:52 #38980 /VacuumLog: Chamber: 20.10 mPa, 31.40 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 26.29 V 16:37:55 #38980 /Trigger: Going through .. 16:37:56 #38980 Discharge/HWTrigger: Going through .. 16:37:56 #38980 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 16:37:56 #38980 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 16:37:56 #38980 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 16:37:56 #38980 /VacuumLog: Chamber: 20.30 mPa, 31.50 C, ForVacuum: 4.95 Pa, Gas: H2, GasValve: 26.29 V 16:38:00 #38980 /VacuumLog: Chamber: 20.50 mPa, 31.50 C, ForVacuum: 5.0 Pa, Gas: H2, GasValve: 26.29 V 16:38:00 #38980 /ChargingResistorsAllON: Diving into .. 16:38:02 #38980 /SecurePostDischargeState: Going through .. 16:38:02 #38980 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:38:03 #38980 /VacuumLog: Chamber: 1.23 mPa, 31.50 C, ForVacuum: 3.3 Pa, Gas: NULL, GasValve: 0.00 V 16:38:07 #38980 /VacuumLog: Chamber: 0.94 mPa, 31.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:38:08 #38980 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:38:11 #38980 /VacuumLog: Chamber: 0.91 mPa, 31.50 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 16:38:14 #38980 /VacuumLog: Chamber: 0.89 mPa, 31.50 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 16:38:17 #38980 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:38:18 #38980 /VacuumLog: Chamber: 0.89 mPa, 31.50 C, ForVacuum: 0.92 Pa, Gas: NULL, GasValve: 0.00 V 16:38:21 #38980 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:38:21 #38980 /VacuumLog: Chamber: 0.89 mPa, 31.50 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 16:38:24 #38980 /DischargeFunction: General Calling FinalDischargeOperations