11:15:23 #38999 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 11:15:23 #38999 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:15:25 #38999 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:15:25 #38999 /VacuumLog: Chamber: 0.90 mPa, 33.00 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 11:15:25 #38999 /GetReadyTheDischarge: Going with gas pressure 20 11:15:25 #38999 /GetReadyTheDischarge: Going with gas type H 11:15:25 #38999 /GetRe11:15:25 #38999 /GetReadyTheDischarge: Diving into .. 11:15:25 #38999 /GetReadyTheDischarge: Discharge with 20 mPa request 11:15:25 #38999 /GetReadyTheDischarge: Discharge with Bt CW request 11:15:26 #38999 /GetReadyTheDischarge: Going with CD_orientation CW 11:15:26 #38999 /GetReadyTheDischarge: Discharge with CD CW request 11:15:29 #38999 /VacuumLog: Chamber: 0.97 mPa, 33.10 C, ForVacuum: 0.98 Pa, Gas: H2, GasValve: 24.78 V 11:15:32 #38999 /VacuumLog: Chamber: 59.70 mPa, 33.00 C, ForVacuum: 3.05 Pa, Gas: H2, GasValve: 25.14 V 11:15:33 #38999 /GetReadyTheDischarge: Bt capacitor charging started 11:15:36 #38999 /VacuumLog: Chamber: 2.73 mPa, 33.00 C, ForVacuum: 5.3 Pa, Gas: H2, GasValve: 22.40 V 11:15:37 #38999 /GetReadyTheDischarge: Cd capacitor charging started 11:15:37 #38999 /ChargingResistorsAllOFF: Diving into .. 11:15:37 #38999 /GetReadyTheDischarge: U_Bt: 900, Hrana: 98 11:15:37 #38999 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 11:15:37 #38999 /GetReadyTheDischarge: Charging ... HV=-11 V 11:15:38 #38999 /GetReadyTheDischarge: Charging ... HV=-11 V 11:15:38 #38999 /GetReadyTheDischarge: Charging ... HV=-11 V 11:15:39 #38999 /GetReadyTheDischarge: Charging ... HV=12 V 11:15:39 #38999 /GetReadyTheDischarge: Charging ... HV=12 V 11:15:40 #38999 /GetReadyTheDischarge: Charging ... HV=60 V 11:15:40 #38999 /GetReadyTheDischarge: Charging ... HV=60 V 11:15:41 #38999 /GetReadyTheDischarge: Charging ... HV=107 V 11:15:41 #38999 /GetReadyTheDischarge: Charging ... HV=107 V 11:15:41 #38999 /GetReadyTheDischarge: Charging ... HV=107 V 11:15:42 #38999 /GetReadyTheDischarge: Charging ... HV=154 V 11:15:42 #38999 /GetReadyTheDischarge: Charging ... HV=154 V 11:15:43 #38999 /GetReadyTheDischarge: Charging ... HV=200 V 11:15:43 #38999 /GetReadyTheDischarge: Charging ... HV=200 V 11:15:43 #38999 /VacuumLog: Chamber: 19.30 mPa, 33.00 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 24.30 V 11:15:44 #38999 /GetReadyTheDischarge: Charging ... HV=200 V 11:15:44 #38999 /GetReadyTheDischarge: Charging ... HV=246 V 11:15:44 #38999 /GetReadyTheDischarge: Charging ... HV=246 V 11:15:45 #38999 /GetReadyTheDischarge: Charging ... HV=291 V 11:15:45 #38999 /GetReadyTheDischarge: Charging ... HV=291 V 11:15:46 #38999 /GetReadyTheDischarge: Charging ... HV=291 V 11:15:46 #38999 /GetReadyTheDischarge: Charging ... HV=333 V 11:15:47 #38999 /GetReadyTheDischarge: Charging ... HV=333 V 11:15:47 #38999 /GetReadyTheDischarge: Charging ... HV=374 V 11:15:47 #38999 /VacuumLog: Chamber: 19.10 mPa, 33.00 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 24.30 V 11:15:48 #38999 /GetReadyTheDischarge: Charging ... HV=374 V 11:15:48 #38999 /GetReadyTheDischarge: Charging ... HV=374 V 11:15:48 #38999 /GetReadyTheDischarge: Charging ... HV=413 V 11:15:49 #38999 /GetReadyTheDischarge: Charging ... HV=413 V 11:15:49 #38999 /GetReadyTheDischarge: Charging ... HV=17 V 11:15:50 #38999 /GetReadyTheDischarge: Charging ... HV=452 V 11:15:50 #38999 /GetReadyTheDischarge: Charging ... HV=489 V 11:15:51 #38999 /GetReadyTheDischarge: Charging ... HV=489 V 11:15:51 #38999 /GetReadyTheDischarge: Charging ... HV=489 V , Gas: H2, GasValve: 24.30 V 11:15:51 #38999 /GetReadyTheDischarge: Charging ... HV=526 V 11:15:52 #38999 /GetReadyTheDischarge: Cd capacitor charging finished @ 526 V 11:15:52 #38999 /GetReadyTheDischarge: Charging ... HV=526 V 11:15:52 #38999 /GetReadyTheDischarge: Charging ... HV=562 V 11:15:53 #38999 /GetReadyTheDischarge: Charging ... HV=562 V 11:15:53 #38999 /GetReadyTheDischarge: Charging ... HV=562 V 11:15:54 #38999 /GetReadyTheDischarge: Charging ... HV=599 V 11:15:54 #38999 /GetReadyTheDischarge: Charging ... HV=599 V 11:15:55 #38999 /GetReadyTheDischarge: Charging ... HV=634 V 11:15:55 #38999 /GetReadyTheDischarge: Charging ... HV=634 V 11:15:55 #38999 /GetReadyTheDischarge: Charging ... HV=634 V 11:15:56 #38999 /GetReadyTheDischarge: Charging ... HV=671 V 11:15:56 #38999 /GetReadyTheDischarge: Charging ... HV=671 V 11:15:57 #38999 /GetReadyTheDischarge: Charging ... HV=707 V 11:15:57 #38999 /GetReadyTheDischarge: Charging ... HV=707 V 11:15:57 #38999 /GetReadyTheDischarge: Charging ... HV=707 V 11:15:58 #38999 /GetReadyTheDischarge: Charging ... HV=740 V 11:15:58 #38999 /GetReadyTheDischarge: Charging ... HV=740 V 11:15:59 #38999 /GetReadyTheDischarge: Charging ... HV=771 V 11:15:59 #38999 /GetReadyTheDischarge: Charging ... HV=771 V 11:16:00 #38999 /GetReadyTheDischarge: Charging ... HV=771 V 11:16:00 #38999 /GetReadyTheDischarge: Charging ... HV=803 V 11:16:00 #38999 /GetReadyTheDischarge: Charging ... HV=803 V 11:16:01 #38999 /GetReadyTheDischarge: Charging ... HV=834 V 11:16:01 #38999 /GetReadyTheDischarge: Charging ... HV=17 V 11:16:02 #38999 /GetReadyTheDischarge: Charging ... HV=834 V 11:16:02 #38999 /GetReadyTheDischarge: Charging ... HV=863 V 11:16:02 #38999 /GetReadyTheDischarge: Charging ... HV=863 V 11:16:03 #38999 /GetReadyTheDischarge: Charging ... HV=863 V 11:16:03 #38999 /GetReadyTheDischarge: Charging ... HV=894 V 11:16:03 #38999 /GetReadyTheDischarge: Bt slow PowSup 11:16:03 #38999 /ChargingResistorsAllON: Diving into .. 11:16:04 #38999 /GetReadyTheDischarge: Charging ... HV=894 V 11:16:04 #38999 /GetReadyTheDischarge: Charging ... HV=921 V 11:16:05 #38999 /ChargingResistorsAllON: Diving into .. 11:16:05 #38999 /GetReadyTheDischarge: Bt capacitor charging finished @ 921 V 11:16:05 #38999 /ChargingResistorsAllON: Diving into .. 11:16:05 #38999 /GetReadyTheDischarge: Ascending from .. .65 Pa, Gas: H2, GasValve: 24.30 V 11:16:05 #38999 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:16:07 #38999 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:16:07 #38999 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:16:09 #38999 /VacuumLog: Chamber: 18.00 mPa, 33.00 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 24.30 V 11:16:09 #38999 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:16:13 #38999 /VacuumLog: Chamber: 17.90 mPa, 33.10 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 24.30 V 11:16:16 #38999 /VacuumLog: Chamber: 17.90 mPa, 33.00 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 24.30 V 11:16:20 #38999 /Trigger: Going through .. 11:16:20 #38999 Discharge/HWTrigger: Going through .. 11:16:20 #38999 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 11:16:20 #38999 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 11:16:20 #38999 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 11:16:24 #38999 /VacuumLog: Chamber: 16.30 mPa, 33.00 C, ForVacuum: 4.3 Pa, Gas: H2, GasValve: 24.30 V 11:16:24 #38999 /ChargingResistorsAllON: Diving into .. 11:16:27 #38999 /SecurePostDischargeState: Going through .. 11:16:27 #38999 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:16:27 #38999 /VacuumLog: Chamber: 2.02 mPa, 33.10 C, ForVacuum: 3.65 Pa, Gas: NULL, GasValve: 0.00 V 11:16:31 #38999 /VacuumLog: Chamber: 1.03 mPa, 33.10 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 11:16:32 #38999 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:16:34 #38999 /VacuumLog: Chamber: 0.97 mPa, 33.10 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V 11:16:38 #38999 /VacuumLog: Chamber: 0.94 mPa, 33.10 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 11:16:42 #38999 /VacuumLog: Chamber: 0.92 mPa, 33.10 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 11:16:45 #38999 /VacuumLog: Chamber: 0.90 mPa, 33.10 C, ForVacuum: 0.955 Pa, Gas: NULL, GasValve: 0.00 V 11:16:49 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.10 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 11:16:53 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.10 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:16:56 #38999 /VacuumLog: Chamber: 0.88 mPa, 33.10 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 11:16:57 #38999 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:17:00 #38999 /VacuumLog: Chamber: 0.88 mPa, 33.10 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 11:17:04 #38999 /VacuumLog: Chamber: 0.88 mPa, 33.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:07 #38999 /VacuumLog: Chamber: 0.88 mPa, 33.00 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:11 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:15 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.00 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:18 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:22 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.00 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:26 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:29 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:31 #38999 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 11:17:33 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.00 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 11:17:37 #38999 /VacuumLog: Chamber: 0.89 mPa, 33.00 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 11:17:38 #38999 /DischargeFunction: General Calling FinalDischargeOperations