11:43:30 #39001 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 11:43:31 #39001 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:43:32 #39001 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:43:33 #39001 /GetReadyTheDischarge: Going with gas pressure 16 11:43:33 #39001 /GetReadyTheDischarge: Going with gas type H 11:43:33 #39001 /GetReadyTheDischarge: Discharge with Hydrogen request 11:43:33 #39001 /GetReadyTheDischarge: Discharge with 16 mPa request 11:43:34 #39001 /VacuumLog: Chamber: 0.90 mPa, 32.40 C, ForVacuum: 0.97 Pa, Gas: H2, GasValve: 0.00 V e: Discharge with Bt CW request 11:43:33 #39001 /GetReadyTheDischarge: Going with CD_orientation CW 11:43:33 #39001 /GetReadyTheDischarge: Discharge with CD CW request 11:43:37 #39001 /VacuumLog: Chamber: 2.97 mPa, 32.40 C, ForVacuum: 1.05 Pa, Gas: H2, GasValve: 25.08 V 11:43:40 #39001 /GetReadyTheDischarge: Bt capacitor charging started 11:43:41 #39001 /VacuumLog: Chamber: 26.00 mPa, 32.40 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 25.92 V 11:43:44 #39001 /VacuumLog: Chamber: 11.30 mPa, 32.40 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 24.30 V 11:43:44 #39001 /GetReadyTheDischarge: Cd capacitor charging started 11:43:45 #39001 /ChargingResistorsAllOFF: Diving into .. 11:43:45 #39001 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 11:43:45 #39001 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 11:43:45 #39001 /GetReadyTheDischarge: Charging ... HV=-13 V 11:43:45 #39001 /GetReadyTheDischarge: Charging ... HV=-7 V 11:43:46 #39001 /GetReadyTheDischarge: Charging ... HV=-7 V 11:43:46 #39001 /GetReadyTheDischarge: Charging ... HV=-7 V 11:43:47 #39001 /GetReadyTheDischarge: Charging ... HV=32 V 11:43:47 #39001 /GetReadyTheDischarge: Charging ... HV=32 V 11:43:48 #39001 /GetReadyTheDischarge: Charging ... HV=81 V 11:43:48 #39001 /GetReadyTheDischarge: Charging ... HV=81 V 11:43:48 #39001 /VacuumLog: Chamber: 16.60 mPa, 32.50 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 24.16 V 11:43:48 #39001 /GetReadyTheDischarge: Charging ... HV=81 V 11:43:49 #39001 /GetReadyTheDischarge: Charging ... HV=127 V 11:43:49 #39001 /GetReadyTheDischarge: Charging ... HV=127 V 11:43:50 #39001 /GetReadyTheDischarge: Charging ... HV=174 V 11:43:50 #39001 /GetReadyTheDischarge: Charging ... HV=174 V 11:43:51 #39001 /GetReadyTheDischarge: Charging ... HV=220 V 11:43:51 #39001 /GetReadyTheDischarge: Charging ... HV=220 V 11:43:51 #39001 /GetReadyTheDischarge: Charging ... HV=220 V 11:43:52 #39001 /GetReadyTheDischarge: Charging ... HV=264 V , Gas: H2, GasValve: 24.16 V 11:43:52 #39001 /GetReadyTheDischarge: Charging ... HV=264 V 11:43:53 #39001 /GetReadyTheDischarge: Charging ... HV=309 V 11:43:53 #39001 /GetReadyTheDischarge: Charging ... HV=309 V 11:43:54 #39001 /GetReadyTheDischarge: Charging ... HV=309 V 11:43:54 #39001 /GetReadyTheDischarge: Charging ... HV=350 V 11:43:55 #39001 /GetReadyTheDischarge: Charging ... HV=350 V 11:43:55 #39001 /GetReadyTheDischarge: Charging ... HV=389 V 11:43:55 #39001 /GetReadyTheDischarge: Charging ... HV=389 V 11:43:56 #39001 /GetReadyTheDischarge: Charging ... HV=389 V 11:43:56 #39001 /GetReadyTheDischarge: Charging ... HV=17 V 11:43:57 #39001 /GetReadyTheDischarge: Charging ... HV=427 V 11:43:57 #39001 /GetReadyTheDischarge: Charging ... HV=468 V 11:43:58 #39001 /GetReadyTheDischarge: Charging ... HV=468 V 11:43:58 #39001 /GetReadyTheDischarge: Charging ... HV=468 V 11:43:58 #39001 /GetReadyTheDischarge: Charging ... HV=503 V 11:43:59 #39001 /GetReadyTheDischarge: Cd capacitor charging finished @ 503 V 11:43:59 #39001 /GetReadyTheDischarge: Charging ... HV=503 V 11:43:59 #39001 /GetReadyTheDischarge: Charging ... HV=539 V 11:44:00 #39001 /GetReadyTheDischarge: Charging ... HV=539 V 11:44:00 #39001 /GetReadyTheDischarge: Charging ... HV=578 V 11:44:01 #39001 /GetReadyTheDischarge: Charging ... HV=578 V 11:44:01 #39001 /GetReadyTheDischarge: Charging ... HV=578 V 11:44:02 #39001 /GetReadyTheDischarge: Charging ... HV=614 V 11:44:02 #39001 /GetReadyTheDischarge: Charging ... HV=614 V 11:44:02 #39001 /GetReadyTheDischarge: Charging ... HV=648 V 11:44:03 #39001 /GetReadyTheDischarge: Charging ... HV=648 V 11:44:03 #39001 /GetReadyTheDischarge: Charging ... HV=648 V 11:44:04 #39001 /GetReadyTheDischarge: Charging ... HV=686 V 11:44:04 #39001 /GetReadyTheDischarge: Charging ... HV=686 V 11:44:05 #39001 /GetReadyTheDischarge: Charging ... HV=721 V 11:44:05 #39001 /GetReadyTheDischarge: Charging ... HV=721 V 11:44:05 #39001 /GetReadyTheDischarge: Charging ... HV=721 V 11:44:06 #39001 /GetReadyTheDischarge: Charging ... HV=753 V 11:44:06 #39001 /GetReadyTheDischarge: Charging ... HV=753 V 11:44:07 #39001 /GetReadyTheDischarge: Charging ... HV=753 V 11:44:07 #39001 /GetReadyTheDischarge: Charging ... HV=784 V 11:44:07 #39001 /GetReadyTheDischarge: Charging ... HV=784 V 11:44:08 #39001 /GetReadyTheDischarge: Charging ... HV=815 V 11:44:08 #39001 /ChargingResistorsAllON: Diving into .. 11:44:08 #39001 /GetReadyTheDischarge: Bt capacitor charging finished @ 815 V 11:44:09 #39001 /ChargingResistorsAllON: Diving into .. 11:44:09 #39001 /GetReadyTheDischarge: Ascending from .. 11:44:09 #39001 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:44:10 #39001 /VacuumLog: Chamber: 14.50 mPa, 32.40 C, ForVacuum: 4.05 Pa, Gas: H2, GasValve: 24.16 V 11:44:11 #39001 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:44:11 #39001 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:44:13 #39001 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:44:14 #39001 /VacuumLog: Chamber: 14.40 mPa, 32.40 C, ForVacuum: 4.05 Pa, Gas: H2, GasValve: 24.16 V 11:44:17 #39001 /VacuumLog: Chamber: 14.40 mPa, 32.40 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 24.16 V 11:44:21 #39001 /VacuumLog: Chamber: 14.30 mPa, 32.30 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 24.16 V 11:44:23 #39001 /Trigger: Going through .. 11:44:24 #39001 Discharge/HWTrigger: Going through .. 11:44:24 #39001 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 11:44:24 #39001 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 11:44:24 #39001 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 11:44:25 #39001 /VacuumLog: Chamber: 14.30 mPa, 32.50 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 24.16 V 11:44:28 #39001 /ChargingResistorsAllON: Diving into .. 11:44:28 #39001 /VacuumLog: Chamber: 14.50 mPa, 32.40 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 24.16 V 11:44:30 #39001 /SecurePostDischargeState: Going through .. 11:44:31 #39001 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:44:32 #39001 /VacuumLog: Chamber: 1.17 mPa, 32.50 C, ForVacuum: 2.45 Pa, Gas: NULL, GasValve: 0.00 V 11:44:35 #39001 /VacuumLog: Chamber: 1.00 mPa, 32.50 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:44:36 #39001 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:44:39 #39001 /VacuumLog: Chamber: 0.95 mPa, 32.50 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 11:44:43 #39001 /VacuumLog: Chamber: 0.93 mPa, 32.50 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 11:44:46 #39001 /VacuumLog: Chamber: 0.91 mPa, 32.40 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 11:44:50 #39001 /VacuumLog: Chamber: 0.90 mPa, 32.50 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 11:44:54 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.50 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 11:44:55 #39001 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:44:57 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.40 C, ForVacuum: 0.955 Pa, Gas: NULL, GasValve: 0.00 V 11:45:01 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.40 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 11:45:05 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.40 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:08 #39001 /VacuumLog: Chamber: 0.88 mPa, 32.40 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:12 #39001 /VacuumLog: Chamber: 0.88 mPa, 32.40 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:16 #39001 /VacuumLog: Chamber: 0.88 mPa, 32.50 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:19 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.50 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:23 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.50 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:26 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.50 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:27 #39001 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 11:45:30 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.40 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 11:45:34 #39001 /VacuumLog: Chamber: 0.89 mPa, 32.50 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 11:45:34 #39001 /DischargeFunction: General Calling FinalDischargeOperations