11:58:37 #39002 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 11:58:38 #39002 /VacuumLog: Chamber: 0.89 mPa, 32.00 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 11:58:39 #39002 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:58:40 #39002 /GetReadyTheDischarge: Going with gas pressure 20 11:58:40 #39002 /GetReadyTheDischarge: Going with gas type H 11:58:40 #39002 /GetReadyTheDischarge: Discharge with Hydrogen request 11:58:40 #39002 /GetReadyTheDischarge: Discharge with 20 mPa request 58:40 #39002 /GetReadyTheDischarge: Going with Bt_orientation CW 11:58:40 #39002 /GetReadyTheDischarge: Discharge with Bt CW request 11:58:40 #39002 /GetReadyTheDischarge: Going with CD_orientation CW 11:58:40 #39002 /GetReadyTheDischarge: Discharge with CD CW request 11:58:41 #39002 /VacuumLog: Chamber: 0.89 mPa, 32.00 C, ForVacuum: 0.97 Pa, Gas: H2, GasValve: 22.87 V 11:58:45 #39002 /VacuumLog: Chamber: 10.80 mPa, 32.00 C, ForVacuum: 1.5 Pa, Gas: H2, GasValve: 26.38 V 11:58:47 #39002 /GetReadyTheDischarge: Bt capacitor charging started 11:58:48 #39002 /VacuumLog: Chamber: 22.30 mPa, 32.00 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 21.29 V 11:58:51 #39002 /GetReadyTheDischarge: Cd capacitor charging started 11:58:51 #39002 /ChargingResistorsAllOFF: Diving into .. 11:58:51 #39002 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 11:58:52 #39002 /GetReadyTheDischarge: U_Et: 600, Hrana: 98 11:58:52 #39002 /GetReadyTheDischarge: Charging ... HV=-11 V 11:58:52 #39002 /GetReadyTheDischarge: Charging ... HV=-11 V , Gas: H2, GasValve: 25.04 V 11:58:53 #39002 /GetReadyTheDischarge: Charging ... HV=8 V 11:58:53 #39002 /GetReadyTheDischarge: Charging ... HV=8 V 11:58:53 #39002 /GetReadyTheDischarge: Charging ... HV=8 V 11:58:54 #39002 /GetReadyTheDischarge: Charging ... HV=55 V 11:58:54 #39002 /GetReadyTheDischarge: Charging ... HV=55 V 11:58:55 #39002 /GetReadyTheDischarge: Charging ... HV=103 V 11:58:55 #39002 /GetReadyTheDischarge: Charging ... HV=103 V 11:58:56 #39002 /GetReadyTheDischarge: Charging ... HV=103 V 11:58:56 #39002 /GetReadyTheDischarge: Charging ... HV=150 V 11:58:57 #39002 /GetReadyTheDischarge: Charging ... HV=150 V 11:58:57 #39002 /GetReadyTheDischarge: Charging ... HV=195 V 11:58:57 #39002 /GetReadyTheDischarge: Charging ... HV=195 V 11:58:58 #39002 /GetReadyTheDischarge: Charging ... HV=18 V 11:58:58 #39002 /GetReadyTheDischarge: Charging ... HV=241 V 11:58:59 #39002 /GetReadyTheDischarge: Charging ... HV=241 V 11:58:59 #39002 /GetReadyTheDischarge: Charging ... HV=286 V 11:59:00 #39002 /GetReadyTheDischarge: Charging ... HV=286 V 11:59:00 #39002 /GetReadyTheDischarge: Charging ... HV=329 V 11:59:00 #39002 /GetReadyTheDischarge: Charging ... HV=329 V 11:59:01 #39002 /GetReadyTheDischarge: Charging ... HV=329 V 11:59:01 #39002 /GetReadyTheDischarge: Charging ... HV=369 V 11:59:02 #39002 /GetReadyTheDischarge: Charging ... HV=369 V 11:59:02 #39002 /GetReadyTheDischarge: Charging ... HV=408 V 11:59:03 #39002 /GetReadyTheDischarge: Charging ... HV=408 V 11:59:03 #39002 /VacuumLog: Chamber: 15.00 mPa, 32.00 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 23.59 V 11:59:03 #39002 /GetReadyTheDischarge: Charging ... HV=408 V 11:59:04 #39002 /GetReadyTheDischarge: Charging ... HV=447 V 11:59:04 #39002 /GetReadyTheDischarge: Charging ... HV=447 V 11:59:04 #39002 /GetReadyTheDischarge: Charging ... HV=485 V 11:59:05 #39002 /GetReadyTheDischarge: Charging ... HV=485 V 11:59:05 #39002 /GetReadyTheDischarge: Charging ... HV=485 V 11:59:06 #39002 /GetReadyTheDischarge: Charging ... HV=522 V 11:59:06 #39002 /GetReadyTheDischarge: Charging ... HV=522 V 11:59:07 #39002 /GetReadyTheDischarge: Charging ... HV=557 V 11:59:07 #39002 /VacuumLog: Chamber: 14.70 mPa, 32.00 C, ForVacuum: 4.1 Pa, Gas: H2, GasValve: 23.59 V 11:59:07 #39002 /GetReadyTheDischarge: Charging ... HV=557 V 11:59:08 #39002 /GetReadyTheDischarge: Charging ... HV=557 V 11:59:08 #39002 /GetReadyTheDischarge: Charging ... HV=592 V 11:59:08 #39002 /GetReadyTheDischarge: Cd slow PowSup 11:59:08 #39002 /ChargingResistorsAllON: Diving into .. 11:59:09 #39002 /GetReadyTheDischarge: Charging ... HV=624 V 11:59:09 #39002 /GetReadyTheDischarge: Cd capacitor charging finished @ 624 V 11:59:09 #39002 /GetReadyTheDischarge: Bt boost PowSup 11:59:09 #39002 /ChargingResistorsAllOFF: Diving into .. 11:59:09 #39002 /GetReadyTheDischarge: Charging ... HV=624 V 11:59:10 #39002 /GetReadyTheDischarge: Charging ... HV=624 V 11:59:10 #39002 /GetReadyTheDischarge: Charging ... HV=641 V 11:59:10 #39002 /VacuumLog: Chamber: 14.50 mPa, 31.90 C, ForVacuum: 4.05 Pa, Gas: H2, GasValve: 23.59 V 11:59:11 #39002 /GetReadyTheDischarge: Charging ... HV=641 V 11:59:11 #39002 /GetReadyTheDischarge: Charging ... HV=677 V 11:59:11 #39002 /GetReadyTheDischarge: Charging ... HV=677 V 11:59:12 #39002 /GetReadyTheDischarge: Charging ... HV=677 V 11:59:12 #39002 /GetReadyTheDischarge: Charging ... HV=712 V 11:59:13 #39002 /GetReadyTheDischarge: Charging ... HV=712 V 11:59:13 #39002 /GetReadyTheDischarge: Charging ... HV=745 V 11:59:13 #39002 /GetReadyTheDischarge: Charging ... HV=745 V 11:59:14 #39002 /GetReadyTheDischarge: Charging ... HV=745 V 11:59:14 #39002 /VacuumLog: Chamber: 14.30 mPa, 32.00 C, ForVacuum: 4.05 Pa, Gas: H2, GasValve: 23.59 V 11:59:14 #39002 /GetReadyTheDischarge: Charging ... HV=776 V 11:59:15 #39002 /GetReadyTheDischarge: Charging ... HV=776 V 11:59:15 #39002 /GetReadyTheDischarge: Charging ... HV=807 V 11:59:15 #39002 /ChargingResistorsAllON: Diving into .. 11:59:16 #39002 /GetReadyTheDischarge: Bt capacitor charging finished @ 807 V 11:59:16 #39002 /ChargingResistorsAllON: Diving into .. 11:59:16 #39002 /GetReadyTheDischarge: Ascending from .. 11:59:16 #39002 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:59:18 #39002 /VacuumLog: Chamber: 14.20 mPa, 32.10 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 23.59 V 11:59:18 #39002 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:59:18 #39002 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:59:20 #39002 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:59:21 #39002 /VacuumLog: Chamber: 14.00 mPa, 32.00 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 23.59 V 11:59:25 #39002 /VacuumLog: Chamber: 13.90 mPa, 32.00 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 23.59 V 11:59:29 #39002 /VacuumLog: Chamber: 13.80 mPa, 32.10 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 23.59 V 11:59:31 #39002 /Trigger: Going through .. 11:59:31 #39002 Discharge/HWTrigger: Going through .. 11:59:31 #39002 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 11:59:31 #39002 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 11:59:31 #39002 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 11:59:32 #39002 /VacuumLog: Chamber: 13.80 mPa, 32.00 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 23.59 V 11:59:35 #39002 /ChargingResistorsAllON: Diving into .. 11:59:36 #39002 /VacuumLog: Chamber: 14.10 mPa, 32.00 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 0.00 V 11:59:38 #39002 /SecurePostDischargeState: Going through .. 11:59:38 #39002 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:59:39 #39002 /VacuumLog: Chamber: 1.10 mPa, 32.10 C, ForVacuum: 2.1 Pa, Gas: NULL, GasValve: 0.00 V 11:59:43 #39002 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:59:43 #39002 /VacuumLog: Chamber: 0.98 mPa, 32.10 C, ForVacuum: 1.05 Pa, Gas: NULL, GasValve: 0.00 V 11:59:47 #39002 /VacuumLog: Chamber: 0.93 mPa, 32.10 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 11:59:50 #39002 /VacuumLog: Chamber: 0.91 mPa, 32.10 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 11:59:54 #39002 /VacuumLog: Chamber: 0.90 mPa, 32.20 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 11:59:58 #39002 /VacuumLog: Chamber: 0.89 mPa, 32.10 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 12:00:01 #39002 /VacuumLog: Chamber: 0.88 mPa, 32.10 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 12:00:02 #39002 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 12:00:05 #39002 /VacuumLog: Chamber: 0.88 mPa, 32.10 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 12:00:09 #39002 /VacuumLog: Chamber: 0.87 mPa, 32.10 C, ForVacuum: 0.955 Pa, Gas: NULL, GasValve: 0.00 V 12:00:12 #39002 /VacuumLog: Chamber: 0.87 mPa, 32.20 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 12:00:16 #39002 /VacuumLog: Chamber: 0.87 mPa, 32.10 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 12:00:20 #39002 /VacuumLog: Chamber: 0.87 mPa, 32.10 C, ForVacuum: 0.985 Pa, Gas: NULL, GasValve: 0.00 V 12:00:23 #39002 /VacuumLog: Chamber: 0.87 mPa, 32.10 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 12:00:27 #39002 /VacuumLog: Chamber: 0.88 mPa, 32.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 12:00:30 #39002 /VacuumLog: Chamber: 0.88 mPa, 32.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 12:00:34 #39002 /VacuumLog: Chamber: 0.88 mPa, 32.10 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 12:00:34 #39002 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 12:00:38 #39002 /VacuumLog: Chamber: 0.88 mPa, 32.10 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 12:00:41 #39002 /DischargeFunction: General Calling FinalDischargeOperations 12:00:41 #39002 /VacuumLog: Chamber: 0.88 mPa, 32.10 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V