11:27:04 #39134 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Dirigent service 11:27:04 #39134 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:27:06 #39134 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:27:06 #39134 /GetReadyTheDischarge: Going with gas pressure 10 11:27:06 #39134 /GetReadyTheDischarge: Going with gas type H 11:27:06 #39134 /GetReadyTheDischarge: Discharge with Hydrogen request 11:27:06 #39134 /VacuumLog: Chamber: 5.46 mPa, 55.10 C, ForVacuum: 2.0 Pa, Gas: 11:27:06 #39134 /GetReadyTheDischarg11:27:06 #39134 /GetReadyTheDischarge: Discha11:27:06 #39134 /GetReadyTheDischarge: Discharge with Bt CW request 11:27:06 #39134 /GetReadyTheDischarge: Going with CD_orientation CW 11:27:06 #39134 /GetReadyTheDischarge: Discharge with CD CW request 11:27:10 #39134 /VacuumLog: Chamber: 5.43 mPa, 55.00 C, ForVacuum: 2.0 Pa, Gas: H2, GasValve: 20.84 V 11:27:13 #39134 /VacuumLog: Chamber: 5.40 mPa, 55.00 C, ForVacuum: 2.0 Pa, Gas: H2, GasValve: 22.21 V 11:27:13 #39134 /GetReadyTheDischarge: Bt capacitor charging started 11:27:17 #39134 /VacuumLog: Chamber: 5.89 mPa, 55.00 C, ForVacuum: 2.05 Pa, Gas: H2, GasValve: 23.10 V 11:27:18 #39134 /GetReadyTheDischarge: Cd capacitor charging started 11:27:18 #39134 /ChargingResistorsAllOFF: Diving into .. 11:27:18 #39134 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 11:27:18 #39134 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 11:27:18 #39134 /GetReadyTheDischarge: Charging ... HV=-14 V 11:27:18 #39134 /GetReadyTheDischarge: Charging ... HV=-10 V 11:27:19 #39134 /GetReadyTheDischarge: Charging ... HV=-10 V 11:27:19 #39134 /GetReadyTheDischarge: Charging ... HV=22 V 11:27:20 #39134 /GetReadyTheDischarge: Charging ... HV=22 V 11:27:20 #39134 /GetReadyTheDischarge: Charging ... HV=22 V 11:27:21 #39134 /GetReadyTheDischarge: Charging ... HV=70 V 11:27:21 #39134 /GetReadyTheDischarge: Charging ... HV=70 V 11:27:22 #39134 /GetReadyTheDischarge: Charging ... HV=117 V 11:27:22 #39134 /GetReadyTheDischarge: Charging ... HV=117 V 11:27:22 #39134 /GetReadyTheDischarge: Charging ... HV=117 V 11:27:23 #39134 /GetReadyTheDischarge: Charging ... HV=163 V 11:27:23 #39134 /GetReadyTheDischarge: Charging ... HV=163 V 11:27:24 #39134 /GetReadyTheDischarge: Charging ... HV=209 V 11:27:24 #39134 /VacuumLog: Chamber: 10.00 mPa, 54.90 C, ForVacuum: 2.8 Pa, Gas: H2, GasValve: 23.99 V 11:27:24 #39134 /GetReadyTheDischarge: Charging ... HV=209 V 11:27:25 #39134 /GetReadyTheDischarge: Charging ... HV=209 V 11:27:25 #39134 /GetReadyTheDischarge: Charging ... HV=254 V 11:27:25 #39134 /GetReadyTheDischarge: Charging ... HV=254 V 11:27:26 #39134 /GetReadyTheDischarge: Charging ... HV=298 V 11:27:26 #39134 /GetReadyTheDischarge: Charging ... HV=298 V 11:27:27 #39134 /GetReadyTheDischarge: Charging ... HV=340 V 11:27:27 #39134 /GetReadyTheDischarge: Charging ... HV=340 V 11:27:28 #39134 /GetReadyTheDischarge: Charging ... HV=340 V Gas: H2, GasValve: 23.99 V 11:27:28 #39134 /GetReadyTheDischarge: Charging ... HV=379 V 11:27:29 #39134 /GetReadyTheDischarge: Charging ... HV=379 V 11:27:29 #39134 /GetReadyTheDischarge: Charging ... HV=418 V 11:27:29 #39134 /GetReadyTheDischarge: Charging ... HV=418 V 11:27:30 #39134 /GetReadyTheDischarge: Charging ... HV=418 V 11:27:30 #39134 /GetReadyTheDischarge: Charging ... HV=457 V 11:27:30 #39134 /GetReadyTheDischarge: Cd capacitor charging finished @ 457 V 11:27:31 #39134 /GetReadyTheDischarge: Charging ... HV=457 V 11:27:31 #39134 /GetReadyTheDischarge: Charging ... HV=494 V 11:27:31 #39134 /VacuumLog: Chamber: 11.40 mPa, 54.80 C, ForVacuum: 3.3 Pa, Gas: H2, GasValve: 23.99 V 11:27:32 #39134 /GetReadyTheDischarge: Charging ... HV=494 V 11:27:32 #39134 /GetReadyTheDischarge: Charging ... HV=494 V 11:27:32 #39134 /GetReadyTheDischarge: Charging ... HV=533 V 11:27:33 #39134 /GetReadyTheDischarge: Charging ... HV=17 V 11:27:33 #39134 /GetReadyTheDischarge: Charging ... HV=572 V 11:27:34 #39134 /GetReadyTheDischarge: Charging ... HV=572 V 11:27:34 #39134 /GetReadyTheDischarge: Charging ... HV=572 V 11:27:35 #39134 /GetReadyTheDischarge: Charging ... HV=609 V 11:27:35 #39134 /GetReadyTheDischarge: Charging ... HV=609 V Gas: H2, GasValve: 23.99 V 11:27:35 #39134 /GetReadyTheDischarge: Charging ... HV=643 V 11:27:36 #39134 /GetReadyTheDischarge: Charging ... HV=643 V 11:27:36 #39134 /GetReadyTheDischarge: Charging ... HV=643 V 11:27:37 #39134 /GetReadyTheDischarge: Charging ... HV=681 V 11:27:37 #39134 /GetReadyTheDischarge: Charging ... HV=681 V 11:27:37 #39134 /GetReadyTheDischarge: Charging ... HV=681 V 11:27:38 #39134 /GetReadyTheDischarge: Charging ... HV=715 V 11:27:38 #39134 /GetReadyTheDischarge: Charging ... HV=715 V 11:27:39 #39134 /GetReadyTheDischarge: Charging ... HV=747 V Gas: H2, GasValve: 23.99 V 11:27:39 #39134 /GetReadyTheDischarge: Charging ... HV=747 V 11:27:40 #39134 /GetReadyTheDischarge: Charging ... HV=747 V 11:27:40 #39134 /GetReadyTheDischarge: Charging ... HV=778 V 11:27:40 #39134 /GetReadyTheDischarge: Charging ... HV=778 V 11:27:41 #39134 /GetReadyTheDischarge: Charging ... HV=809 V 11:27:41 #39134 /ChargingResistorsAllON: Diving into .. 11:27:41 #39134 /GetReadyTheDischarge: Bt capacitor charging finished @ 809 V 11:27:42 #39134 /ChargingResistorsAllON: Diving into .. 11:27:42 #39134 /GetReadyTheDischarge: Ascending from .. 11:27:42 #39134 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:27:42 #39134 /VacuumLog: Chamber: 13.30 mPa, 54.70 C, ForVacuum: 3.65 Pa, Gas: H2, GasValve: 23.99 V 11:27:44 #39134 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:27:44 #39134 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:27:44 #39134 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:27:46 #39134 /VacuumLog: Chamber: 13.60 mPa, 54.70 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 23.99 V 11:27:49 #39134 /VacuumLog: Chamber: 13.90 mPa, 54.60 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 23.99 V 11:27:53 #39134 /VacuumLog: Chamber: 14.40 mPa, 54.60 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 23.99 V 11:27:54 #39134 /Trigger: Going through .. 11:27:55 #39134 Discharge/HWTrigger: Going through .. 11:27:55 #39134 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 11:27:55 #39134 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 11:27:55 #39134 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 11:27:57 #39134 /VacuumLog: Chamber: 14.80 mPa, 54.50 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 23.99 V 11:27:59 #39134 /ChargingResistorsAllON: Diving into .. 11:28:00 #39134 /VacuumLog: Chamber: 12.00 mPa, 54.50 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 0.00 V 11:28:01 #39134 /SecurePostDischargeState: Going through .. 11:28:02 #39134 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:28:04 #39134 /VacuumLog: Chamber: 5.33 mPa, 54.50 C, ForVacuum: 2.4 Pa, Gas: NULL, GasValve: 0.00 V 11:28:07 #39134 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:28:08 #39134 /VacuumLog: Chamber: 5.23 mPa, 54.40 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 11:28:11 #39134 /VacuumLog: Chamber: 5.17 mPa, 54.40 C, ForVacuum: 1.9 Pa, Gas: NULL, GasValve: 0.00 V 11:28:15 #39134 /VacuumLog: Chamber: 5.13 mPa, 54.30 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 11:28:18 #39134 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:28:18 #39134 /VacuumLog: Chamber: 5.09 mPa, 54.30 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 11:28:22 #39134 /VacuumLog: Chamber: 5.06 mPa, 54.30 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 11:28:23 #39134 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 11:28:26 #39134 /VacuumLog: Chamber: 5.02 mPa, 54.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 11:28:29 #39134 /VacuumLog: Chamber: 5.00 mPa, 54.20 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 11:28:30 #39134 /DischargeFunction: General Calling FinalDischargeOperations