15:51:02 #39174   Discharge/PrepareDischargeEnv@SHM:	Command Line Request: EDU (MHD + biasing)               
15:51:02 #39174   /Broadcast:	**Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end               
15:51:04 #39174   /LogTheDeviceAction:	The Preionization action on stage with GetReadyTheDischarge         
15:51:04 #39174   /GetReadyTheDischarge:	Going with gas pressure 10               
15:51:04 #39174   /GetReadyTheDischarge:	Going with gas type H               
15:51:04 #39174   /GetReadyTheDischarge:	Discharge with Hydrogen request               
15:51:04 #39174   /GetReadyTheDischarge:	Discharge with 10 mPa request               
15:51:05 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 0.00 V               
 Bt_orientation CW               
15:51:04 #39174   /GetReadyTheDischarge:	Discharge with Bt CW request               
15:51:05 #39174   /GetReadyTheDischarge:	Going with CD_orientation CW               
15:51:05 #39174   /GetReadyTheDischarge:	Discharge with CD CW request               
15:51:09 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 22.87 V               
15:51:12 #39174   /GetReadyTheDischarge:	Bt capacitor charging started               
15:51:12 #39174   /VacuumLog:	Chamber: 1.37 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 24.63 V               
15:51:16 #39174   /VacuumLog:	Chamber: 4.57 mPa,  38.40 C, ForVacuum: 1.6 Pa, Gas: H2, GasValve: 26.80 V               
15:51:16 #39174   /GetReadyTheDischarge:	Cd capacitor charging started               
15:51:16 #39174   /ChargingResistorsAllOFF:	Diving into ..             
15:51:16 #39174   /GetReadyTheDischarge:	U_Bt: 1150, Hrana: 98               
15:51:16 #39174   /GetReadyTheDischarge:	U_Et: 700, Hrana: 98               
15:51:16 #39174   /GetReadyTheDischarge:	Charging ... HV=-11 V               
15:51:17 #39174   /GetReadyTheDischarge:	Charging ... HV=-11 V               
15:51:17 #39174   /GetReadyTheDischarge:	Charging ... HV=0 V               
15:51:18 #39174   /GetReadyTheDischarge:	Charging ... HV=0 V               
15:51:18 #39174   /GetReadyTheDischarge:	Charging ... HV=45 V               
15:51:18 #39174   /GetReadyTheDischarge:	Charging ... HV=45 V               
15:51:19 #39174   /GetReadyTheDischarge:	Charging ... HV=45 V               
15:51:19 #39174   /GetReadyTheDischarge:	Charging ... HV=93 V               
15:51:19 #39174   /VacuumLog:	Chamber: 12.80 mPa,  38.50 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 26.62 V               
15:51:20 #39174   /GetReadyTheDischarge:	Charging ... HV=93 V               
15:51:20 #39174   /GetReadyTheDischarge:	Charging ... HV=138 V               
15:51:21 #39174   /GetReadyTheDischarge:	Charging ... HV=138 V               
15:51:21 #39174   /GetReadyTheDischarge:	Charging ... HV=138 V               
15:51:22 #39174   /GetReadyTheDischarge:	Charging ... HV=184 V               
15:51:22 #39174   /GetReadyTheDischarge:	Charging ... HV=184 V               
15:51:22 #39174   /GetReadyTheDischarge:	Charging ... HV=231 V               
15:51:23 #39174   /GetReadyTheDischarge:	Charging ... HV=231 V               
15:51:23 #39174   /GetReadyTheDischarge:	Charging ... HV=231 V               
, Gas: H2, GasValve: 26.62 V               
15:51:24 #39174   /GetReadyTheDischarge:	Charging ... HV=275 V               
15:51:24 #39174   /GetReadyTheDischarge:	Charging ... HV=275 V               
15:51:25 #39174   /GetReadyTheDischarge:	Charging ... HV=320 V               
15:51:25 #39174   /GetReadyTheDischarge:	Charging ... HV=320 V               
15:51:25 #39174   /GetReadyTheDischarge:	Charging ... HV=361 V               
15:51:26 #39174   /GetReadyTheDischarge:	Charging ... HV=361 V               
15:51:26 #39174   /GetReadyTheDischarge:	Charging ... HV=361 V               
15:51:27 #39174   /GetReadyTheDischarge:	Charging ... HV=399 V               
15:51:27 #39174   /GetReadyTheDischarge:	Charging ... HV=399 V               
, Gas: H2, GasValve: 26.62 V               
15:51:28 #39174   /GetReadyTheDischarge:	Charging ... HV=438 V               
15:51:28 #39174   /GetReadyTheDischarge:	Charging ... HV=438 V               
15:51:29 #39174   /GetReadyTheDischarge:	Charging ... HV=438 V               
15:51:29 #39174   /GetReadyTheDischarge:	Charging ... HV=477 V               
15:51:29 #39174   /GetReadyTheDischarge:	Charging ... HV=477 V               
15:51:30 #39174   /GetReadyTheDischarge:	Charging ... HV=513 V               
15:51:30 #39174   /GetReadyTheDischarge:	Charging ... HV=513 V               
15:51:31 #39174   /GetReadyTheDischarge:	Charging ... HV=513 V               
15:51:31 #39174   /GetReadyTheDischarge:	Charging ... HV=548 V               
15:51:32 #39174   /GetReadyTheDischarge:	Charging ... HV=548 V               
15:51:32 #39174   /GetReadyTheDischarge:	Charging ... HV=584 V               
15:51:33 #39174   /GetReadyTheDischarge:	Charging ... HV=584 V               
15:51:33 #39174   /GetReadyTheDischarge:	Charging ... HV=584 V               
15:51:33 #39174   /GetReadyTheDischarge:	Charging ... HV=616 V               
15:51:34 #39174   /GetReadyTheDischarge:	Charging ... HV=616 V               
15:51:34 #39174   /VacuumLog:	Chamber: 20.10 mPa,  38.40 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 26.62 V               
15:51:34 #39174   /GetReadyTheDischarge:	Charging ... HV=648 V               
15:51:35 #39174   /GetReadyTheDischarge:	Charging ... HV=648 V               
15:51:35 #39174   /GetReadyTheDischarge:	Charging ... HV=683 V               
15:51:36 #39174   /GetReadyTheDischarge:	Charging ... HV=683 V               
15:51:36 #39174   /GetReadyTheDischarge:	Charging ... HV=683 V               
15:51:36 #39174   /GetReadyTheDischarge:	Charging ... HV=714 V               
15:51:37 #39174   /GetReadyTheDischarge:	Cd capacitor charging finished @ 714 V               
15:51:37 #39174   /GetReadyTheDischarge:	Charging ... HV=714 V               
15:51:37 #39174   /GetReadyTheDischarge:	Charging ... HV=744 V               
15:51:38 #39174   /VacuumLog:	Chamber: 20.30 mPa,  38.40 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 26.62 V               
15:51:38 #39174   /GetReadyTheDischarge:	Charging ... HV=744 V               
15:51:38 #39174   /GetReadyTheDischarge:	Charging ... HV=744 V               
15:51:39 #39174   /GetReadyTheDischarge:	Charging ... HV=775 V               
15:51:39 #39174   /GetReadyTheDischarge:	Charging ... HV=775 V               
15:51:40 #39174   /GetReadyTheDischarge:	Charging ... HV=806 V               
15:51:40 #39174   /GetReadyTheDischarge:	Charging ... HV=806 V               
15:51:40 #39174   /GetReadyTheDischarge:	Charging ... HV=21 V               
15:51:41 #39174   /GetReadyTheDischarge:	Charging ... HV=838 V               
15:51:41 #39174   /GetReadyTheDischarge:	Charging ... HV=838 V               
15:51:41 #39174   /VacuumLog:	Chamber: 20.50 mPa,  38.40 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 26.62 V               
15:51:42 #39174   /GetReadyTheDischarge:	Charging ... HV=866 V               
15:51:42 #39174   /GetReadyTheDischarge:	Charging ... HV=866 V               
15:51:43 #39174   /GetReadyTheDischarge:	Charging ... HV=866 V               
15:51:43 #39174   /GetReadyTheDischarge:	Charging ... HV=897 V               
15:51:43 #39174   /GetReadyTheDischarge:	Charging ... HV=897 V               
15:51:44 #39174   /GetReadyTheDischarge:	Charging ... HV=925 V               
15:51:44 #39174   /GetReadyTheDischarge:	Charging ... HV=925 V               
15:51:45 #39174   /GetReadyTheDischarge:	Charging ... HV=925 V               
15:51:45 #39174   /GetReadyTheDischarge:	Charging ... HV=954 V               
 Gas: H2, GasValve: 26.62 V               
15:51:45 #39174   /GetReadyTheDischarge:	Charging ... HV=954 V               
15:51:46 #39174   /GetReadyTheDischarge:	Charging ... HV=21 V               
15:51:46 #39174   /GetReadyTheDischarge:	Charging ... HV=981 V               
15:51:47 #39174   /GetReadyTheDischarge:	Charging ... HV=981 V               
15:51:47 #39174   /GetReadyTheDischarge:	Charging ... HV=1005 V               
15:51:48 #39174   /GetReadyTheDischarge:	Charging ... HV=1005 V               
15:51:48 #39174   /GetReadyTheDischarge:	Charging ... HV=1005 V               
15:51:48 #39174   /GetReadyTheDischarge:	Charging ... HV=1030 V               
15:51:49 #39174   /GetReadyTheDischarge:	Charging ... HV=1030 V               
Gas: H2, GasValve: 26.62 V               
15:51:49 #39174   /GetReadyTheDischarge:	Charging ... HV=1057 V               
15:51:50 #39174   /GetReadyTheDischarge:	Charging ... HV=1057 V               
15:51:50 #39174   /GetReadyTheDischarge:	Charging ... HV=1057 V               
15:51:51 #39174   /GetReadyTheDischarge:	Charging ... HV=1082 V               
15:51:51 #39174   /GetReadyTheDischarge:	Charging ... HV=1082 V               
15:51:51 #39174   /GetReadyTheDischarge:	Charging ... HV=21 V               
15:51:52 #39174   /GetReadyTheDischarge:	Charging ... HV=1105 V               
15:51:52 #39174   /GetReadyTheDischarge:	Charging ... HV=1105 V               
15:51:53 #39174   /GetReadyTheDischarge:	Charging ... HV=1127 V               
15:51:53 #39174   /GetReadyTheDischarge:	Charging ... HV=1127 V               
15:51:54 #39174   /GetReadyTheDischarge:	Charging ... HV=1148 V               
15:51:54 #39174   /GetReadyTheDischarge:	Bt slow PowSup               
15:51:54 #39174   /ChargingResistorsAllON:	Diving into ..             
15:51:54 #39174   /GetReadyTheDischarge:	Charging ... HV=1148 V               
15:51:55 #39174   /GetReadyTheDischarge:	Charging ... HV=1167 V               
15:51:55 #39174   /ChargingResistorsAllON:	Diving into ..             
15:51:55 #39174   /GetReadyTheDischarge:	Bt capacitor charging finished @ 1167 V               
15:51:55 #39174   /ChargingResistorsAllON:	Diving into ..             
15:51:56 #39174   /GetReadyTheDischarge:	Ascending from ..             
15:51:56 #39174   /Broadcast:	**ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end               
15:51:56 #39174   /VacuumLog:	Chamber: 21.20 mPa,  38.40 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 26.62 V               
15:51:57 #39174   TektrMSO56-a/LogTheDeviceAction:	The BasicDiagnostics action on stage with Arming         
15:51:57 #39174   TektrMSO56-a/LogTheDeviceAction:	The BasicDiagnostics action on stage with Arming         
15:51:57 #39174   TektrMSO58-a/LogTheDeviceAction:	The 21_RunAways_JCetal action on stage with Arming         
15:51:57 #39174   TektrMSO64-a/LogTheDeviceAction:	The TunnelProbe action on stage with Arming         
15:51:59 #39174   /VacuumLog:	Chamber: 21.40 mPa,  38.40 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 26.62 V               
15:52:03 #39174   /VacuumLog:	Chamber: 21.60 mPa,  38.40 C, ForVacuum: 5.3 Pa, Gas: H2, GasValve: 26.62 V               
15:52:04 #39174   /Broadcast:	**ActualShot: ARMING@EVERYWHERE end               
15:52:07 #39174   /VacuumLog:	Chamber: 21.80 mPa,  38.40 C, ForVacuum: 5.3 Pa, Gas: H2, GasValve: 26.62 V               
15:52:10 #39174   /VacuumLog:	Chamber: 22.00 mPa,  38.40 C, ForVacuum: 5.35 Pa, Gas: H2, GasValve: 26.62 V               
15:52:14 #39174   /VacuumLog:	Chamber: 22.20 mPa,  38.40 C, ForVacuum: 5.35 Pa, Gas: H2, GasValve: 26.62 V               
15:52:15 #39174   /Trigger:	Going through ..             
15:52:15 #39174   Discharge/HWTrigger:	Going through ..             
15:52:15 #39174   Discharge/HWTrigger:	Going with trigger Tch3 - TBt 0               
15:52:15 #39174   Discharge/HWTrigger:	Going with trigger Tch4 - Tcd 1900               
15:52:15 #39174   Discharge/HWTrigger:	Going with trigger Tch5 - Tist 3100               
15:52:18 #39174   /VacuumLog:	Chamber: 17.00 mPa,  38.40 C, ForVacuum: 5.25 Pa, Gas: H2, GasValve: 26.62 V               
15:52:19 #39174   /ChargingResistorsAllON:	Diving into ..             
15:52:21 #39174   /VacuumLog:	Chamber: 5.94 mPa,  38.50 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 0.00 V               
15:52:22 #39174   /SecurePostDischargeState:	Going through ..             
15:52:22 #39174   /Broadcast:	**ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end               
15:52:25 #39174   /VacuumLog:	Chamber: 1.51 mPa,  38.50 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:27 #39174   /Broadcast:	**ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end               
15:52:29 #39174   /VacuumLog:	Chamber: 1.42 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:30 #39174   Papouch-Za/RawDataAcquiring:	Papouch-Za: Start of acquiring               
15:52:30 #39174   NIstandard/RawDataAcquiring:	NIstandard: Start of acquiring               
15:52:31 #39174   NIstandard/RawDataAcquiring:	NIstandard: End of acquiring               
15:52:32 #39174   /VacuumLog:	Chamber: 1.34 mPa,  38.50 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:34 #39174   TektrMSO58-a/getdata:	TektrMSO58-a: Start of acquiring               
15:52:34 #39174   TektrMSO58-a/getdata:	TektrMSO58-a: End of acquiring               
15:52:36 #39174   /VacuumLog:	Chamber: 1.29 mPa,  38.60 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:39 #39174   /VacuumLog:	Chamber: 1.26 mPa,  38.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:43 #39174   /VacuumLog:	Chamber: 1.23 mPa,  38.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:47 #39174   /VacuumLog:	Chamber: 1.21 mPa,  38.60 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:49 #39174   Papouch-Za/RawDataAcquiring:	Papouch-Za: End of acquiring               
15:52:50 #39174   /VacuumLog:	Chamber: 1.19 mPa,  38.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:54 #39174   /VacuumLog:	Chamber: 1.18 mPa,  38.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:52:58 #39174   /VacuumLog:	Chamber: 1.18 mPa,  38.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:01 #39174   /VacuumLog:	Chamber: 1.17 mPa,  38.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:05 #39174   /VacuumLog:	Chamber: 1.16 mPa,  38.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:05 #39174   /Broadcast:	**ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end               
15:53:08 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:12 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:16 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:19 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:23 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:27 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:30 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:34 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:38 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:41 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:45 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:49 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:52 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:53:56 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:54:00 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:54:03 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:54:07 #39174   /VacuumLog:	Chamber: 1.14 mPa,  38.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:54:08 #39174   /Broadcast:	**ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end               
15:54:11 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:54:14 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V               
15:54:16 #39174   /DischargeFunction:	General Calling FinalDischargeOperations               
15:54:18 #39174   /VacuumLog:	Chamber: 1.15 mPa,  38.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V