16:25:57 #39179 Discharge/PrepareDischargeEnv@SHM: Command Line Request: EDU (MHD + biasing) 16:25:57 #39179 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:25:57 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:25:59 #39179 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:25:59 #39179 /GetReadyTheDischarge: Going with gas pressure 10 16:25:59 #39179 /GetReadyTheDischarge: Going with gas type H 16:25:59 #39179 /GetReadyTheDischarge: Discharge with Hydrogen request 16:25:59 #39179 /GetReadyTheDischarge: Discharge with 10 mPa request 16:25:59 #39179 /GetReadyTheDischarge: Diving into .. 16:25:59 #39179 /GetReadyTheDischarge: Going with Bt_orientation CW 16:25:59 #39179 /GetReadyTheDischarge: Discharge with Bt CW request 16:26:00 #39179 /GetReadyTheDischarge: Going with CD_orientation CW 16:26:00 #39179 /GetReadyTheDischarge: Discharge with CD CW request 16:26:01 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 21.10 V 16:26:04 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 22.87 V 16:26:07 #39179 /GetReadyTheDischarge: Bt capacitor charging started 16:26:08 #39179 /VacuumLog: Chamber: 1.67 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 25.49 V 16:26:11 #39179 /GetReadyTheDischarge: Cd capacitor charging started 16:26:11 #39179 /ChargingResistorsAllOFF: Diving into .. 16:26:11 #39179 /GetReadyTheDischarge: U_Bt: 1150, Hrana: 98 16:26:11 #39179 /GetReadyTheDischarge: U_Et: 700, Hrana: 98 16:26:11 #39179 /GetReadyTheDischarge: Charging ... HV=-11 V 16:26:12 #39179 /GetReadyTheDischarge: Charging ... HV=-3 V Gas: H2, GasValve: 26.75 V 16:26:12 #39179 /GetReadyTheDischarge: Charging ... HV=-3 V 16:26:13 #39179 /GetReadyTheDischarge: Charging ... HV=-3 V 16:26:13 #39179 /GetReadyTheDischarge: Charging ... HV=39 V 16:26:14 #39179 /GetReadyTheDischarge: Charging ... HV=39 V 16:26:14 #39179 /GetReadyTheDischarge: Charging ... HV=87 V 16:26:14 #39179 /GetReadyTheDischarge: Charging ... HV=87 V 16:26:15 #39179 /GetReadyTheDischarge: Charging ... HV=87 V 16:26:15 #39179 /GetReadyTheDischarge: Charging ... HV=133 V 16:26:16 #39179 /GetReadyTheDischarge: Charging ... HV=133 V , Gas: H2, GasValve: 26.94 V 16:26:16 #39179 /GetReadyTheDischarge: Charging ... HV=179 V 16:26:17 #39179 /GetReadyTheDischarge: Charging ... HV=179 V 16:26:17 #39179 /GetReadyTheDischarge: Charging ... HV=179 V 16:26:17 #39179 /GetReadyTheDischarge: Charging ... HV=225 V 16:26:18 #39179 /GetReadyTheDischarge: Charging ... HV=225 V 16:26:18 #39179 /GetReadyTheDischarge: Charging ... HV=269 V 16:26:19 #39179 /GetReadyTheDischarge: Charging ... HV=269 V 16:26:19 #39179 /GetReadyTheDischarge: Charging ... HV=269 V 16:26:20 #39179 /GetReadyTheDischarge: Charging ... HV=314 V 16:26:20 #39179 /GetReadyTheDischarge: Charging ... HV=314 V 16:26:21 #39179 /GetReadyTheDischarge: Charging ... HV=355 V 16:26:21 #39179 /GetReadyTheDischarge: Charging ... HV=355 V 16:26:21 #39179 /GetReadyTheDischarge: Charging ... HV=355 V 16:26:22 #39179 /GetReadyTheDischarge: Charging ... HV=394 V 16:26:22 #39179 /GetReadyTheDischarge: Charging ... HV=394 V 16:26:23 #39179 /GetReadyTheDischarge: Charging ... HV=432 V 16:26:23 #39179 /GetReadyTheDischarge: Charging ... HV=432 V 16:26:24 #39179 /GetReadyTheDischarge: Charging ... HV=472 V 16:26:24 #39179 /GetReadyTheDischarge: Charging ... HV=472 V 16:26:24 #39179 /GetReadyTheDischarge: Charging ... HV=472 V 16:26:25 #39179 /GetReadyTheDischarge: Charging ... HV=508 V 16:26:25 #39179 /GetReadyTheDischarge: Charging ... HV=508 V 16:26:26 #39179 /GetReadyTheDischarge: Charging ... HV=544 V 16:26:26 #39179 /GetReadyTheDischarge: Charging ... HV=544 V 16:26:26 #39179 /VacuumLog: Chamber: 22.40 mPa, 37.40 C, ForVacuum: 5.35 Pa, Gas: H2, GasValve: 26.94 V 16:26:27 #39179 /GetReadyTheDischarge: Charging ... HV=544 V 16:26:27 #39179 /GetReadyTheDischarge: Charging ... HV=580 V 16:26:28 #39179 /GetReadyTheDischarge: Charging ... HV=580 V 16:26:28 #39179 /GetReadyTheDischarge: Charging ... HV=612 V 16:26:28 #39179 /GetReadyTheDischarge: Charging ... HV=612 V 16:26:29 #39179 /GetReadyTheDischarge: Charging ... HV=612 V 16:26:29 #39179 /GetReadyTheDischarge: Charging ... HV=643 V 16:26:30 #39179 /GetReadyTheDischarge: Charging ... HV=643 V 16:26:30 #39179 /GetReadyTheDischarge: Charging ... HV=678 V , Gas: H2, GasValve: 26.94 V 16:26:31 #39179 /GetReadyTheDischarge: Charging ... HV=678 V 16:26:31 #39179 /GetReadyTheDischarge: Charging ... HV=678 V 16:26:31 #39179 /GetReadyTheDischarge: Charging ... HV=710 V 16:26:32 #39179 /GetReadyTheDischarge: Cd capacitor charging finished @ 710 V 16:26:32 #39179 /GetReadyTheDischarge: Charging ... HV=710 V 16:26:32 #39179 /GetReadyTheDischarge: Charging ... HV=740 V 16:26:33 #39179 /GetReadyTheDischarge: Charging ... HV=740 V 16:26:33 #39179 /GetReadyTheDischarge: Charging ... HV=771 V 16:26:34 #39179 /GetReadyTheDischarge: Charging ... HV=771 V 16:26:34 #39179 /VacuumLog: Chamber: 23.40 mPa, 37.40 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 26.94 V 16:26:34 #39179 /GetReadyTheDischarge: Charging ... HV=771 V 16:26:35 #39179 /GetReadyTheDischarge: Charging ... HV=802 V 16:26:35 #39179 /GetReadyTheDischarge: Charging ... HV=802 V 16:26:35 #39179 /GetReadyTheDischarge: Charging ... HV=22 V 16:26:36 #39179 /GetReadyTheDischarge: Charging ... HV=834 V 16:26:36 #39179 /GetReadyTheDischarge: Charging ... HV=834 V 16:26:37 #39179 /GetReadyTheDischarge: Charging ... HV=862 V 16:26:37 #39179 /GetReadyTheDischarge: Charging ... HV=862 V 16:26:38 #39179 /GetReadyTheDischarge: Charging ... HV=862 V , Gas: H2, GasValve: 26.94 V 16:26:38 #39179 /GetReadyTheDischarge: Charging ... HV=893 V 16:26:38 #39179 /GetReadyTheDischarge: Charging ... HV=893 V 16:26:39 #39179 /GetReadyTheDischarge: Charging ... HV=921 V 16:26:39 #39179 /GetReadyTheDischarge: Charging ... HV=921 V 16:26:40 #39179 /GetReadyTheDischarge: Charging ... HV=921 V 16:26:40 #39179 /GetReadyTheDischarge: Charging ... HV=950 V 16:26:40 #39179 /GetReadyTheDischarge: Charging ... HV=950 V 16:26:41 #39179 /GetReadyTheDischarge: Charging ... HV=977 V 16:26:41 #39179 /GetReadyTheDischarge: Charging ... HV=977 V Gas: H2, GasValve: 26.94 V 16:26:42 #39179 /GetReadyTheDischarge: Charging ... HV=977 V 16:26:42 #39179 /GetReadyTheDischarge: Charging ... HV=1002 V 16:26:43 #39179 /GetReadyTheDischarge: Charging ... HV=1002 V 16:26:43 #39179 /GetReadyTheDischarge: Charging ... HV=1026 V 16:26:43 #39179 /GetReadyTheDischarge: Charging ... HV=1026 V 16:26:44 #39179 /GetReadyTheDischarge: Charging ... HV=1026 V 16:26:44 #39179 /GetReadyTheDischarge: Charging ... HV=1053 V 16:26:45 #39179 /GetReadyTheDischarge: Charging ... HV=1053 V 16:26:45 #39179 /GetReadyTheDischarge: Charging ... HV=1078 V 16:26:46 #39179 /GetReadyTheDischarge: Charging ... HV=1078 V 16:26:46 #39179 /GetReadyTheDischarge: Charging ... HV=1078 V 16:26:46 #39179 /GetReadyTheDischarge: Charging ... HV=1101 V 16:26:47 #39179 /GetReadyTheDischarge: Charging ... HV=1101 V 16:26:47 #39179 /GetReadyTheDischarge: Charging ... HV=1123 V 16:26:48 #39179 /GetReadyTheDischarge: Charging ... HV=1123 V 16:26:48 #39179 /GetReadyTheDischarge: Charging ... HV=1123 V 16:26:49 #39179 /GetReadyTheDischarge: Charging ... HV=1144 V 16:26:49 #39179 /GetReadyTheDischarge: Bt slow PowSup 16:26:49 #39179 /ChargingResistorsAllON: Diving into .. 16:26:49 #39179 /GetReadyTheDischarge: Charging ... HV=1144 V 16:26:50 #39179 /GetReadyTheDischarge: Charging ... HV=1164 V 16:26:50 #39179 /ChargingResistorsAllON: Diving into .. 16:26:50 #39179 /GetReadyTheDischarge: Bt capacitor charging finished @ 1164 V 16:26:50 #39179 /ChargingResistorsAllON: Diving into .. 16:26:51 #39179 /GetReadyTheDischarge: Ascending from .. 16:26:51 #39179 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:26:52 #39179 /VacuumLog: Chamber: 25.30 mPa, 37.40 C, ForVacuum: 5.75 Pa, Gas: H2, GasValve: 26.94 V 16:26:52 #39179 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:26:52 #39179 TektrMSO64-a/LogTheDeviceAction: The TunnelProbe action on stage with Arming 16:26:53 #39179 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:26:53 #39179 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_JCetal action on stage with Arming 16:26:56 #39179 /VacuumLog: Chamber: 25.60 mPa, 37.40 C, ForVacuum: 5.75 Pa, Gas: H2, GasValve: 26.94 V 16:26:57 #39179 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:26:59 #39179 /VacuumLog: Chamber: 26.00 mPa, 37.40 C, ForVacuum: 5.8 Pa, Gas: H2, GasValve: 26.94 V 16:27:03 #39179 /VacuumLog: Chamber: 26.30 mPa, 37.40 C, ForVacuum: 5.85 Pa, Gas: H2, GasValve: 26.94 V 16:27:07 #39179 /VacuumLog: Chamber: 26.70 mPa, 37.40 C, ForVacuum: 5.85 Pa, Gas: H2, GasValve: 26.94 V 16:27:07 #39179 /Trigger: Going through .. 16:27:07 #39179 Discharge/HWTrigger: Going through .. 16:27:07 #39179 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:27:07 #39179 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1900 16:27:07 #39179 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3100 16:27:10 #39179 /VacuumLog: Chamber: 21.20 mPa, 37.00 C, ForVacuum: 5.7 Pa, Gas: H2, GasValve: 26.94 V 16:27:12 #39179 /ChargingResistorsAllON: Diving into .. 16:27:14 #39179 /VacuumLog: Chamber: 4.30 mPa, 37.40 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 0.00 V 16:27:14 #39179 /SecurePostDischargeState: Going through .. 16:27:14 #39179 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:27:18 #39179 /VacuumLog: Chamber: 1.50 mPa, 37.50 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 16:27:19 #39179 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:27:21 #39179 /VacuumLog: Chamber: 1.39 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:23 #39179 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 16:27:23 #39179 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:27:23 #39179 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:27:25 #39179 /VacuumLog: Chamber: 1.33 mPa, 37.50 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 16:27:27 #39179 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 16:27:27 #39179 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 16:27:29 #39179 /VacuumLog: Chamber: 1.28 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:32 #39179 /VacuumLog: Chamber: 1.24 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:36 #39179 /VacuumLog: Chamber: 1.22 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:40 #39179 /VacuumLog: Chamber: 1.20 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:42 #39179 Papouch-Za/RawDataAcquiring: Papouch-Za: End of acquiring 16:27:43 #39179 /VacuumLog: Chamber: 1.18 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:47 #39179 /VacuumLog: Chamber: 1.17 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:51 #39179 /VacuumLog: Chamber: 1.16 mPa, 37.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:54 #39179 /VacuumLog: Chamber: 1.15 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:58 #39179 /VacuumLog: Chamber: 1.15 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:27:58 #39179 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:28:02 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:28:05 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:28:09 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:28:13 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:16 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:20 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.50 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:24 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:27 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:31 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:35 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:38 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:42 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:46 #39179 /VacuumLog: Chamber: 1.13 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:49 #39179 /VacuumLog: Chamber: 1.15 mPa, 37.30 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:53 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:28:57 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.30 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:29:00 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.30 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:29:01 #39179 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:29:04 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.30 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:29:07 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:29:09 #39179 /DischargeFunction: General Calling FinalDischargeOperations 16:29:11 #39179 /VacuumLog: Chamber: 1.14 mPa, 37.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V