16:50:00 #39181 Discharge/PrepareDischargeEnv@SHM: Command Line Request: EDU (MHD + biasing) 16:50:00 #39181 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:50:02 #39181 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:50:02 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:50:02 #39181 /GetReadyTheDischarge: Going with gas pressure 10 16:50:02 #39181 /GetReadyTheDischarge: Going with gas type H 16:50:02 #39181 /GetReadyTheDischarge: Discharge with Hydrogen requ16:50:02 #39181 /16:50:02 #39181 /GetReadyTheDischarge: Discharge with 10 mPa req16:50:02 #39181 /GetReadyTheDischarge: Discharge with Bt CW request 16:50:02 #39181 /GetReadyTheDischarge: Going with CD_orientation CW 16:50:02 #39181 /GetReadyTheDischarge: Discharge with CD CW request 16:50:05 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 21.99 V 16:50:09 #39181 /VacuumLog: Chamber: 1.17 mPa, 37.10 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 24.65 V 16:50:09 #39181 /GetReadyTheDischarge: Bt capacitor charging started 16:50:13 #39181 /VacuumLog: Chamber: 2.76 mPa, 37.20 C, ForVacuum: 1.4 Pa, Gas: H2, GasValve: 26.21 V 16:50:14 #39181 /GetReadyTheDischarge: Cd capacitor charging started 16:50:14 #39181 /ChargingResistorsAllOFF: Diving into .. 16:50:14 #39181 /GetReadyTheDischarge: U_Bt: 1150, Hrana: 98 16:50:14 #39181 /GetReadyTheDischarge: U_Et: 700, Hrana: 98 16:50:14 #39181 /GetReadyTheDischarge: Charging ... HV=-10 V 16:50:15 #39181 /GetReadyTheDischarge: Charging ... HV=-10 V 16:50:15 #39181 /GetReadyTheDischarge: Charging ... HV=7 V 16:50:15 #39181 /GetReadyTheDischarge: Charging ... HV=7 V 16:50:16 #39181 /GetReadyTheDischarge: Charging ... HV=7 V 16:50:16 #39181 /GetReadyTheDischarge: Charging ... HV=54 V 16:50:17 #39181 /GetReadyTheDischarge: Charging ... HV=54 V 16:50:17 #39181 /GetReadyTheDischarge: Charging ... HV=102 V 16:50:18 #39181 /GetReadyTheDischarge: Charging ... HV=102 V 16:50:18 #39181 /GetReadyTheDischarge: Charging ... HV=102 V 16:50:18 #39181 /GetReadyTheDischarge: Charging ... HV=148 V 16:50:19 #39181 /GetReadyTheDischarge: Charging ... HV=148 V 16:50:19 #39181 /GetReadyTheDischarge: Charging ... HV=193 V 16:50:20 #39181 /GetReadyTheDischarge: Charging ... HV=193 V 16:50:20 #39181 /VacuumLog: Chamber: 12.40 mPa, 37.10 C, ForVacuum: 3.5 Pa, Gas: H2, GasValve: 26.90 V 16:50:20 #39181 /GetReadyTheDischarge: Charging ... HV=193 V 16:50:21 #39181 /GetReadyTheDischarge: Charging ... HV=240 V 16:50:21 #39181 /GetReadyTheDischarge: Charging ... HV=240 V 16:50:22 #39181 /GetReadyTheDischarge: Charging ... HV=284 V 16:50:22 #39181 /GetReadyTheDischarge: Charging ... HV=284 V 16:50:22 #39181 /GetReadyTheDischarge: Charging ... HV=328 V 16:50:23 #39181 /GetReadyTheDischarge: Charging ... HV=328 V 16:50:23 #39181 /GetReadyTheDischarge: Charging ... HV=328 V 16:50:24 #39181 /GetReadyTheDischarge: Charging ... HV=368 V 16:50:24 #39181 /VacuumLog: Chamber: 18.60 mPa, 37.20 C, ForVacuum: 4.4 Pa, Gas: H2, GasValve: 26.90 V 16:50:24 #39181 /GetReadyTheDischarge: Charging ... HV=368 V 16:50:25 #39181 /GetReadyTheDischarge: Charging ... HV=406 V 16:50:25 #39181 /GetReadyTheDischarge: Charging ... HV=406 V 16:50:25 #39181 /GetReadyTheDischarge: Charging ... HV=406 V 16:50:26 #39181 /GetReadyTheDischarge: Charging ... HV=22 V 16:50:26 #39181 /GetReadyTheDischarge: Charging ... HV=445 V 16:50:27 #39181 /GetReadyTheDischarge: Charging ... HV=484 V 16:50:27 #39181 /GetReadyTheDischarge: Charging ... HV=484 V 16:50:28 #39181 /GetReadyTheDischarge: Charging ... HV=484 V Gas: H2, GasValve: 26.90 V 16:50:28 #39181 /GetReadyTheDischarge: Charging ... HV=520 V 16:50:29 #39181 /GetReadyTheDischarge: Charging ... HV=520 V 16:50:29 #39181 /GetReadyTheDischarge: Charging ... HV=555 V 16:50:29 #39181 /GetReadyTheDischarge: Charging ... HV=22 V 16:50:30 #39181 /GetReadyTheDischarge: Charging ... HV=555 V 16:50:30 #39181 /GetReadyTheDischarge: Charging ... HV=590 V 16:50:31 #39181 /GetReadyTheDischarge: Charging ... HV=590 V 16:50:31 #39181 /GetReadyTheDischarge: Charging ... HV=622 V 16:50:32 #39181 /GetReadyTheDischarge: Charging ... HV=622 V 16:50:32 #39181 /GetReadyTheDischarge: Charging ... HV=654 V 16:50:33 #39181 /GetReadyTheDischarge: Charging ... HV=654 V 16:50:33 #39181 /GetReadyTheDischarge: Charging ... HV=654 V 16:50:33 #39181 /GetReadyTheDischarge: Charging ... HV=689 V 16:50:34 #39181 /GetReadyTheDischarge: Cd slow PowSup 16:50:34 #39181 /ChargingResistorsAllON: Diving into .. 16:50:34 #39181 /GetReadyTheDischarge: Charging ... HV=689 V 16:50:34 #39181 /GetReadyTheDischarge: Charging ... HV=718 V 16:50:35 #39181 /GetReadyTheDischarge: Cd capacitor charging finished @ 718 V 16:50:35 #39181 /GetReadyTheDischarge: Bt boost PowSup 16:50:35 #39181 /ChargingResistorsAllOFF: Diving into .. 16:50:35 #39181 /GetReadyTheDischarge: Charging ... HV=718 V 16:50:36 #39181 /GetReadyTheDischarge: Charging ... HV=727 V 16:50:36 #39181 /GetReadyTheDischarge: Charging ... HV=22 V 16:50:36 #39181 /GetReadyTheDischarge: Charging ... HV=752 V 16:50:37 #39181 /GetReadyTheDischarge: Charging ... HV=752 V 16:50:37 #39181 /GetReadyTheDischarge: Charging ... HV=752 V 16:50:38 #39181 /GetReadyTheDischarge: Charging ... HV=784 V 16:50:38 #39181 /GetReadyTheDischarge: Charging ... HV=784 V 16:50:39 #39181 /GetReadyTheDischarge: Charging ... HV=815 V 16:50:39 #39181 /GetReadyTheDischarge: Charging ... HV=815 V 16:50:39 #39181 /GetReadyTheDischarge: Charging ... HV=815 V 16:50:40 #39181 /GetReadyTheDischarge: Charging ... HV=846 V 16:50:40 #39181 /GetReadyTheDischarge: Charging ... HV=846 V 16:50:41 #39181 /GetReadyTheDischarge: Charging ... HV=846 V 16:50:41 #39181 /GetReadyTheDischarge: Charging ... HV=875 V 16:50:41 #39181 /GetReadyTheDischarge: Charging ... HV=22 V 16:50:42 #39181 /GetReadyTheDischarge: Charging ... HV=904 V 16:50:42 #39181 /GetReadyTheDischarge: Charging ... HV=904 V 16:50:43 #39181 /GetReadyTheDischarge: Charging ... HV=904 V 16:50:43 #39181 /GetReadyTheDischarge: Charging ... HV=933 V 16:50:43 #39181 /GetReadyTheDischarge: Charging ... HV=933 V 16:50:44 #39181 /GetReadyTheDischarge: Charging ... HV=961 V 16:50:44 #39181 /GetReadyTheDischarge: Charging ... HV=961 V 16:50:45 #39181 /GetReadyTheDischarge: Charging ... HV=961 V 16:50:45 #39181 /GetReadyTheDischarge: Charging ... HV=987 V 16:50:46 #39181 /VacuumLog: Chamber: 22.50 mPa, 37.10 C, ForVacuum: 5.45 Pa, Gas: H2, GasValve: 26.90 V 16:50:46 #39181 /GetReadyTheDischarge: Charging ... HV=987 V 16:50:46 #39181 /GetReadyTheDischarge: Charging ... HV=987 V 16:50:46 #39181 /GetReadyTheDischarge: Charging ... HV=1011 V 16:50:47 #39181 /GetReadyTheDischarge: Charging ... HV=1011 V 16:50:47 #39181 /GetReadyTheDischarge: Charging ... HV=1038 V 16:50:48 #39181 /GetReadyTheDischarge: Charging ... HV=1038 V 16:50:48 #39181 /GetReadyTheDischarge: Charging ... HV=1038 V 16:50:49 #39181 /GetReadyTheDischarge: Charging ... HV=1065 V 16:50:49 #39181 /GetReadyTheDischarge: Charging ... HV=1065 V 16:50:49 #39181 /VacuumLog: Chamber: 22.90 mPa, 37.10 C, ForVacuum: 5.5 Pa, Gas: H2, GasValve: 26.90 V 16:50:49 #39181 /GetReadyTheDischarge: Charging ... HV=1089 V 16:50:50 #39181 /GetReadyTheDischarge: Charging ... HV=1089 V 16:50:50 #39181 /GetReadyTheDischarge: Charging ... HV=1089 V 16:50:51 #39181 /GetReadyTheDischarge: Charging ... HV=1112 V 16:50:51 #39181 /GetReadyTheDischarge: Charging ... HV=1112 V 16:50:52 #39181 /GetReadyTheDischarge: Charging ... HV=1133 V 16:50:52 #39181 /GetReadyTheDischarge: Bt slow PowSup 16:50:52 #39181 /ChargingResistorsAllON: Diving into .. 16:50:52 #39181 /GetReadyTheDischarge: Charging ... HV=1133 V 16:50:53 #39181 /GetReadyTheDischarge: Charging ... HV=1152 V 16:50:53 #39181 /ChargingResistorsAllON: Diving into .. 16:50:53 #39181 /GetReadyTheDischarge: Bt capacitor charging finished @ 1152 V : 26.90 V 16:50:53 #39181 /ChargingResistorsAllON: Diving into .. 16:50:54 #39181 /GetReadyTheDischarge: Ascending from .. 16:50:54 #39181 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:50:55 #39181 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:50:55 #39181 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:50:55 #39181 TektrMSO64-a/LogTheDeviceAction: The TunnelProbe action on stage with Arming 16:50:55 #39181 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_JCetal action on stage with Arming 16:50:57 #39181 /VacuumLog: Chamber: 23.50 mPa, 37.10 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 26.90 V 16:51:00 #39181 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:51:00 #39181 /VacuumLog: Chamber: 24.00 mPa, 37.10 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 26.90 V 16:51:04 #39181 /VacuumLog: Chamber: 24.30 mPa, 37.20 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 26.90 V 16:51:08 #39181 /VacuumLog: Chamber: 24.60 mPa, 37.10 C, ForVacuum: 5.65 Pa, Gas: H2, GasValve: 26.90 V 16:51:10 #39181 /Trigger: Going through .. 16:51:10 #39181 Discharge/HWTrigger: Going through .. 16:51:10 #39181 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:51:10 #39181 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1900 16:51:10 #39181 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3100 16:51:11 #39181 /VacuumLog: Chamber: 24.90 mPa, 37.10 C, ForVacuum: 5.7 Pa, Gas: H2, GasValve: 26.90 V 16:51:15 #39181 /ChargingResistorsAllON: Diving into .. 16:51:15 #39181 /VacuumLog: Chamber: 25.90 mPa, 37.20 C, ForVacuum: 5.4 Pa, Gas: H2, GasValve: 26.90 V 16:51:17 #39181 /SecurePostDischargeState: Going through .. 16:51:17 #39181 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:51:18 #39181 /VacuumLog: Chamber: 1.69 mPa, 37.20 C, ForVacuum: 3.5 Pa, Gas: NULL, GasValve: 0.00 V 16:51:22 #39181 /VacuumLog: Chamber: 1.40 mPa, 37.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:51:22 #39181 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:51:26 #39181 /VacuumLog: Chamber: 1.34 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:26 #39181 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 16:51:26 #39181 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:51:26 #39181 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:51:29 #39181 /VacuumLog: Chamber: 1.28 mPa, 37.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 16:51:30 #39181 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 16:51:30 #39181 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 16:51:33 #39181 /VacuumLog: Chamber: 1.24 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:37 #39181 /VacuumLog: Chamber: 1.21 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:40 #39181 /VacuumLog: Chamber: 1.19 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:44 #39181 /VacuumLog: Chamber: 1.18 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:45 #39181 Papouch-Za/RawDataAcquiring: Papouch-Za: End of acquiring 16:51:48 #39181 /VacuumLog: Chamber: 1.16 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:51 #39181 /VacuumLog: Chamber: 1.15 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:55 #39181 /VacuumLog: Chamber: 1.15 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:51:58 #39181 /VacuumLog: Chamber: 1.14 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:00 #39181 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:52:02 #39181 /VacuumLog: Chamber: 1.14 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:06 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:09 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:13 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:17 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:20 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:24 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:28 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:31 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:35 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:39 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:42 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:46 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:50 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:53 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 16:52:57 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.30 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:53:01 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:53:04 #39181 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:53:04 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:53:08 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:53:12 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:53:12 #39181 /DischargeFunction: General Calling FinalDischargeOperations 16:53:15 #39181 /VacuumLog: Chamber: 1.13 mPa, 37.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V