16:14:41 #39257 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Radiometer commissioning 16:14:42 #39257 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:14:43 #39257 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:14:44 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.00 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:14:44 #39257 /GetReadyTheDischarge: Going with gas pressure 0 16:14:44 #39257 /GetReadyTheDischarge: Going with gas type H 16:14:44 #39257 /GetReadyTheDischarge: Vacuum discharge ! 16:14:44 #39257 /GetReadyTheDischarge: Diving into .. 16:14:44 #39257 /GetReadyTheDischarge: Going with Bt_orientation CW 16:14:44 #39257 /GetReadyTheDischarge: Discharge with Bt CW request 16:14:44 #39257 /GetReadyTheDischarge: Going with CD_orientation CW 16:14:44 #39257 /GetReadyTheDischarge: Discharge with CD CW request 16:14:47 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:14:51 #39257 /VacuumLog: Chamber: 1.15 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:14:51 #39257 /GetReadyTheDischarge: Bt capacitor charging started 16:14:55 #39257 /VacuumLog: Chamber: 1.15 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:14:55 #39257 /GetReadyTheDischarge: Cd capacitor charging started 16:14:55 #39257 /ChargingResistorsAllOFF: Diving into .. 16:14:56 #39257 /GetReadyTheDischarge: U_Bt: 300, Hrana: 98 16:14:56 #39257 /GetReadyTheDischarge: U_Et: 300, Hrana: 98 16:14:56 #39257 /GetReadyTheDischarge: Charging ... HV=-11 V 16:14:56 #39257 /GetReadyTheDischarge: Charging ... HV=-11 V 16:14:57 #39257 /GetReadyTheDischarge: Charging ... HV=-11 V 16:14:57 #39257 /GetReadyTheDischarge: Charging ... HV=20 V 16:14:58 #39257 /GetReadyTheDischarge: Charging ... HV=20 V 16:14:58 #39257 /GetReadyTheDischarge: Charging ... HV=68 V 16:14:58 #39257 /GetReadyTheDischarge: Charging ... HV=68 V 16:14:59 #39257 /GetReadyTheDischarge: Charging ... HV=68 V 16:14:59 #39257 /GetReadyTheDischarge: Charging ... HV=115 V 16:15:00 #39257 /GetReadyTheDischarge: Charging ... HV=115 V 16:15:00 #39257 /GetReadyTheDischarge: Charging ... HV=162 V 16:15:01 #39257 /GetReadyTheDischarge: Charging ... HV=162 V 16:15:01 #39257 /GetReadyTheDischarge: Charging ... HV=162 V 16:15:02 #39257 /GetReadyTheDischarge: Charging ... HV=208 V 16:15:02 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:02 #39257 /GetReadyTheDischarge: Charging ... HV=208 V 16:15:02 #39257 /GetReadyTheDischarge: Charging ... HV=254 V 16:15:03 #39257 /GetReadyTheDischarge: Charging ... HV=254 V 16:15:03 #39257 /GetReadyTheDischarge: Charging ... HV=254 V 16:15:04 #39257 /GetReadyTheDischarge: Charging ... HV=298 V 16:15:04 #39257 /GetReadyTheDischarge: Bt slow PowSup 16:15:04 #39257 /ChargingResistorsAllON: Diving into .. 16:15:04 #39257 /GetReadyTheDischarge: Charging ... HV=298 V 16:15:05 #39257 /GetReadyTheDischarge: Charging ... HV=339 V 16:15:05 #39257 /GetReadyTheDischarge: Bt capacitor charging finished @ 339 V 16:15:05 #39257 /ChargingResistorsAllON: Diving into .. 16:15:05 #39257 /GetReadyTheDischarge: Cd capacitor charging finished @ 339 V 16:15:06 #39257 /ChargingResistorsAllON: Diving into .. 16:15:06 #39257 /GetReadyTheDischarge: Ascending from .. 16:15:06 #39257 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:15:08 #39257 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:15:08 #39257 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:15:08 #39257 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_JCetal action on stage with Arming 16:15:09 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:10 #39257 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:15:13 #39257 /VacuumLog: Chamber: 1.15 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:16 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:20 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:20 #39257 /Trigger: Going through .. 16:15:20 #39257 Discharge/HWTrigger: Going through .. 16:15:20 #39257 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:15:21 #39257 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 450 16:15:21 #39257 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4550 16:15:24 #39257 /VacuumLog: Chamber: 1.15 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:25 #39257 /ChargingResistorsAllON: Diving into .. 16:15:27 #39257 /SecurePostDischargeState: Going through .. 16:15:27 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:27 #39257 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:15:31 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:33 #39257 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:15:35 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:38 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:42 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:46 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:49 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:53 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:54 #39257 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:15:56 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:15:58 #39257 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:15:58 #39257 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:16:00 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:02 #39257 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 16:16:02 #39257 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 16:16:04 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:07 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:11 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:15 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:18 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:22 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:26 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:29 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:33 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:37 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:40 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:44 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:47 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:51 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:52 #39257 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:16:55 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:16:55 #39257 /DischargeFunction: General Calling FinalDischargeOperations 16:16:58 #39257 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V