16:19:32 #39258 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Radiometer commissioning 16:19:33 #39258 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:19:34 #39258 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:19:34 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:19:35 #39258 /GetReadyTheDischarge: Going with gas pressure 0 16:19:35 #39258 /GetReadyTheDischarge: Going with gas type H 16:19:35 #39258 /GetReadyTheDischarge: Vacuum discharge ! o .. 16:19:35 #39258 /GetReadyTheDischarge: Going with Bt_orientation CW 16:19:35 #39258 /GetReadyTheDischarge: Discharge with Bt CW request 16:19:35 #39258 /GetReadyTheDischarge: Going with CD_orientation CW 16:19:35 #39258 /GetReadyTheDischarge: Discharge with CD CW request 16:19:38 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:19:42 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:19:42 #39258 /GetReadyTheDischarge: Bt capacitor charging started 16:19:45 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:19:46 #39258 /GetReadyTheDischarge: Cd capacitor charging started 16:19:46 #39258 /ChargingResistorsAllOFF: Diving into .. 16:19:46 #39258 /GetReadyTheDischarge: U_Bt: 300, Hrana: 98 16:19:47 #39258 /GetReadyTheDischarge: U_Et: 300, Hrana: 98 16:19:47 #39258 /GetReadyTheDischarge: Charging ... HV=-15 V 16:19:47 #39258 /GetReadyTheDischarge: Charging ... HV=-11 V 16:19:48 #39258 /GetReadyTheDischarge: Charging ... HV=-11 V 16:19:48 #39258 /GetReadyTheDischarge: Charging ... HV=24 V 16:19:48 #39258 /GetReadyTheDischarge: Charging ... HV=24 V 16:19:49 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:19:49 #39258 /GetReadyTheDischarge: Charging ... HV=24 V 16:19:49 #39258 /GetReadyTheDischarge: Charging ... HV=73 V 16:19:50 #39258 /GetReadyTheDischarge: Charging ... HV=73 V 16:19:50 #39258 /GetReadyTheDischarge: Charging ... HV=120 V 16:19:51 #39258 /GetReadyTheDischarge: Charging ... HV=120 V 16:19:51 #39258 /GetReadyTheDischarge: Charging ... HV=120 V 16:19:52 #39258 /GetReadyTheDischarge: Charging ... HV=167 V 16:19:52 #39258 /GetReadyTheDischarge: Charging ... HV=167 V 16:19:52 #39258 /GetReadyTheDischarge: Charging ... HV=213 V 16:19:52 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:19:53 #39258 /GetReadyTheDischarge: Charging ... HV=213 V 16:19:53 #39258 /GetReadyTheDischarge: Charging ... HV=213 V 16:19:54 #39258 /GetReadyTheDischarge: Charging ... HV=259 V 16:19:54 #39258 /GetReadyTheDischarge: Charging ... HV=259 V 16:19:55 #39258 /GetReadyTheDischarge: Charging ... HV=304 V 16:19:55 #39258 /GetReadyTheDischarge: Bt capacitor charging finished @ 304 V 16:19:55 #39258 /ChargingResistorsAllON: Diving into .. 16:19:55 #39258 /GetReadyTheDischarge: Cd capacitor charging finished @ 304 V 16:19:56 #39258 /ChargingResistorsAllON: Diving into .. 16:19:56 #39258 /GetReadyTheDischarge: Ascending from .. 16:19:56 #39258 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:19:56 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:19:58 #39258 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:19:58 #39258 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:19:58 #39258 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_JCetal action on stage with Arming 16:20:00 #39258 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:20:00 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:03 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:07 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:10 #39258 /Trigger: Going through .. 16:20:10 #39258 Discharge/HWTrigger: Going through .. 16:20:10 #39258 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:20:10 #39258 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 450 16:20:11 #39258 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4550 16:20:11 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:14 #39258 /VacuumLog: Chamber: 1.14 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:15 #39258 /ChargingResistorsAllON: Diving into .. 16:20:17 #39258 /SecurePostDischargeState: Going through .. 16:20:17 #39258 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:20:18 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:22 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:22 #39258 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:20:25 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:29 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:33 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:36 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:40 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:44 #39258 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:20:44 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:47 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:48 #39258 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:20:48 #39258 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:20:51 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:51 #39258 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 16:20:52 #39258 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 16:20:55 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:20:58 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:02 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:05 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:09 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:13 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:16 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:20 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:24 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:27 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:31 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:34 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:38 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:42 #39258 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:21:42 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:21:45 #39258 /DischargeFunction: General Calling FinalDischargeOperations 16:21:45 #39258 /VacuumLog: Chamber: 1.13 mPa, 34.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V