11:58:18 #39263 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Exkurze - Gymnazium Rokycany 11:58:18 #39263 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:58:18 #39263 /VacuumLog: Chamber: 1.22 mPa, 34.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 11:58:20 #39263 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:58:20 #39263 /GetReadyTheDischarge: Going with gas pressure 16 11:58:20 #39263 /GetReadyTheDischarge: Going with gas type H 11:58:20 #39263 /GetReadyTheDischarge: Discharge with Hydrogen request 11:58:20 #39263 /GetReadyTheDischarge: Discharge with 16 mPa request 11:58:20 #39263 /GetReadyTheDischarge: Discharge with Bt CW request 11:58:21 #39263 /GetReadyTheDischarge: Going with CD_orientation CW 11:58:21 #39263 /GetReadyTheDischarge: Discharge with CD CW request 11:58:22 #39263 /VacuumLog: Chamber: 1.22 mPa, 34.20 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 22.12 V 11:58:25 #39263 /VacuumLog: Chamber: 2.03 mPa, 34.20 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 25.07 V 11:58:27 #39263 /GetReadyTheDischarge: Bt capacitor charging started 11:58:29 #39263 /VacuumLog: Chamber: 27.70 mPa, 34.20 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 26.30 V 11:58:32 #39263 /GetReadyTheDischarge: Cd capacitor charging started 11:58:32 #39263 /ChargingResistorsAllOFF: Diving into .. 11:58:32 #39263 /GetReadyTheDischarge: U_Bt: 500, Hrana: 98 11:58:32 #39263 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 11:58:32 #39263 /GetReadyTheDischarge: Charging ... HV=-12 V 11:58:33 #39263 /GetReadyTheDischarge: Charging ... HV=-12 V 11:58:33 #39263 /VacuumLog: Chamber: 11.70 mPa, 34.20 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 23.41 V 11:58:33 #39263 /GetReadyTheDischarge: Charging ... HV=-3 V 11:58:33 #39263 /GetReadyTheDischarge: Charging ... HV=-3 V 11:58:34 #39263 /GetReadyTheDischarge: Charging ... HV=17 V 11:58:34 #39263 /GetReadyTheDischarge: Charging ... HV=40 V 11:58:35 #39263 /GetReadyTheDischarge: Charging ... HV=40 V 11:58:35 #39263 /GetReadyTheDischarge: Charging ... HV=88 V 11:58:36 #39263 /GetReadyTheDischarge: Charging ... HV=88 V 11:58:36 #39263 /GetReadyTheDischarge: Charging ... HV=134 V 11:58:37 #39263 /GetReadyTheDischarge: Charging ... HV=134 V , Gas: H2, GasValve: 25.31 V 11:58:37 #39263 /GetReadyTheDischarge: Charging ... HV=181 V 11:58:37 #39263 /GetReadyTheDischarge: Charging ... HV=181 V 11:58:38 #39263 /GetReadyTheDischarge: Charging ... HV=181 V 11:58:38 #39263 /GetReadyTheDischarge: Charging ... HV=227 V 11:58:39 #39263 /GetReadyTheDischarge: Charging ... HV=227 V 11:58:39 #39263 /GetReadyTheDischarge: Charging ... HV=271 V 11:58:40 #39263 /GetReadyTheDischarge: Charging ... HV=271 V 11:58:40 #39263 /GetReadyTheDischarge: Charging ... HV=271 V 11:58:41 #39263 /GetReadyTheDischarge: Charging ... HV=317 V 11:58:41 #39263 /GetReadyTheDischarge: Charging ... HV=317 V 11:58:41 #39263 /GetReadyTheDischarge: Charging ... HV=357 V 11:58:42 #39263 /GetReadyTheDischarge: Charging ... HV=357 V 11:58:42 #39263 /GetReadyTheDischarge: Charging ... HV=357 V 11:58:43 #39263 /GetReadyTheDischarge: Charging ... HV=396 V 11:58:43 #39263 /GetReadyTheDischarge: Charging ... HV=396 V 11:58:44 #39263 /GetReadyTheDischarge: Charging ... HV=436 V 11:58:44 #39263 /GetReadyTheDischarge: Charging ... HV=436 V 11:58:44 #39263 /GetReadyTheDischarge: Charging ... HV=17 V 11:58:45 #39263 /GetReadyTheDischarge: Charging ... HV=475 V 11:58:45 #39263 /GetReadyTheDischarge: Charging ... HV=475 V 11:58:46 #39263 /GetReadyTheDischarge: Charging ... HV=511 V 11:58:46 #39263 /GetReadyTheDischarge: Bt capacitor charging finished @ 511 V 11:58:46 #39263 /ChargingResistorsAllON: Diving into .. 11:58:46 #39263 /GetReadyTheDischarge: Cd capacitor charging finished @ 511 V 11:58:47 #39263 /ChargingResistorsAllON: Diving into .. 11:58:47 #39263 /GetReadyTheDischarge: Ascending from .. 11:58:47 #39263 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:58:47 #39263 /VacuumLog: Chamber: 19.30 mPa, 34.20 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 25.31 V 11:58:49 #39263 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:58:49 #39263 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:58:49 #39263 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:58:51 #39263 /VacuumLog: Chamber: 19.20 mPa, 34.20 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.31 V 11:58:55 #39263 /VacuumLog: Chamber: 19.10 mPa, 34.20 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.31 V 11:58:58 #39263 /VacuumLog: Chamber: 19.00 mPa, 34.20 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.31 V 11:59:00 #39263 /Trigger: Going through .. 11:59:00 #39263 Discharge/HWTrigger: Going through .. 11:59:00 #39263 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 11:59:00 #39263 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 100 11:59:00 #39263 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4900 11:59:02 #39263 /VacuumLog: Chamber: 18.90 mPa, 34.20 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.31 V 11:59:04 #39263 /ChargingResistorsAllON: Diving into .. 11:59:06 #39263 /VacuumLog: Chamber: 14.60 mPa, 34.20 C, ForVacuum: 4.75 Pa, Gas: H2, GasValve: 0.00 V 11:59:07 #39263 /SecurePostDischargeState: Going through .. 11:59:07 #39263 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:59:09 #39263 /VacuumLog: Chamber: 1.26 mPa, 34.20 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 11:59:12 #39263 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:59:13 #39263 /VacuumLog: Chamber: 1.22 mPa, 34.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 11:59:17 #39263 /VacuumLog: Chamber: 1.20 mPa, 34.20 C, ForVacuum: 1.1 Pa, Gas: NULL, GasValve: 0.00 V 11:59:20 #39263 /VacuumLog: Chamber: 1.19 mPa, 34.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:21 #39263 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:59:24 #39263 /VacuumLog: Chamber: 1.19 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:28 #39263 /VacuumLog: Chamber: 1.19 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:31 #39263 /VacuumLog: Chamber: 1.19 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:35 #39263 /VacuumLog: Chamber: 1.19 mPa, 34.30 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:39 #39263 /VacuumLog: Chamber: 1.20 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:42 #39263 /VacuumLog: Chamber: 1.20 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:46 #39263 /VacuumLog: Chamber: 1.20 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:50 #39263 /VacuumLog: Chamber: 1.20 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:53 #39263 /VacuumLog: Chamber: 1.22 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 11:59:57 #39263 /VacuumLog: Chamber: 1.21 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 12:00:01 #39263 /VacuumLog: Chamber: 1.21 mPa, 34.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:00:03 #39263 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 12:00:04 #39263 /VacuumLog: Chamber: 1.21 mPa, 34.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 12:00:07 #39263 /DischargeFunction: General Calling FinalDischargeOperations