09:57:28 #39280 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Plasma position stabilization 09:57:28 #39280 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 09:57:28 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.30 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:57:30 #39280 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 09:57:30 #39280 /GetReadyTheDischarge: Going with gas pressure 20 09:57:30 #39280 /GetReadyTheDischarge: Going with gas type H 09:57:30 #39280 /GetReadyTheDischarge: Discharge with Hydrogen request 09:57:30 #39280 /GetReadyTheDischarge: Discharge with 20 mPa request 57:30 #39280 /GetReadyTheDischarge: Going with Bt_orientation CW 09:57:30 #39280 /GetReadyTheDischarge: Discharge with Bt CW request 09:57:30 #39280 /GetReadyTheDischarge: Going with CD_orientation CW 09:57:30 #39280 /GetReadyTheDischarge: Discharge with CD CW request 09:57:32 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.30 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 22.82 V 09:57:35 #39280 /VacuumLog: Chamber: 9.90 mPa, 41.30 C, ForVacuum: 1.8 Pa, Gas: H2, GasValve: 26.52 V 09:57:37 #39280 /GetReadyTheDischarge: Bt capacitor charging started 09:57:39 #39280 /VacuumLog: Chamber: 21.30 mPa, 41.30 C, ForVacuum: 4.95 Pa, Gas: H2, GasValve: 24.67 V 09:57:42 #39280 /GetReadyTheDischarge: Cd capacitor charging started 09:57:42 #39280 /ChargingResistorsAllOFF: Diving into .. 09:57:42 #39280 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 09:57:42 #39280 /GetReadyTheDischarge: U_Et: 400, Hrana: 98 09:57:42 #39280 /GetReadyTheDischarge: Charging ... HV=-12 V 09:57:43 #39280 /GetReadyTheDischarge: Charging ... HV=-12 V 09:57:43 #39280 /VacuumLog: Chamber: 20.40 mPa, 41.30 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 25.41 V 09:57:43 #39280 /GetReadyTheDischarge: Charging ... HV=-12 V 09:57:43 #39280 /GetReadyTheDischarge: Charging ... HV=10 V 09:57:44 #39280 /GetReadyTheDischarge: Charging ... HV=10 V 09:57:44 #39280 /GetReadyTheDischarge: Charging ... HV=57 V 09:57:45 #39280 /GetReadyTheDischarge: Charging ... HV=57 V 09:57:45 #39280 /GetReadyTheDischarge: Charging ... HV=105 V 09:57:46 #39280 /GetReadyTheDischarge: Charging ... HV=105 V 09:57:46 #39280 /GetReadyTheDischarge: Charging ... HV=105 V 09:57:47 #39280 /GetReadyTheDischarge: Charging ... HV=151 V Gas: H2, GasValve: 25.16 V 09:57:47 #39280 /GetReadyTheDischarge: Charging ... HV=151 V 09:57:47 #39280 /GetReadyTheDischarge: Charging ... HV=196 V 09:57:48 #39280 /GetReadyTheDischarge: Charging ... HV=196 V 09:57:48 #39280 /GetReadyTheDischarge: Charging ... HV=196 V 09:57:49 #39280 /GetReadyTheDischarge: Charging ... HV=242 V 09:57:49 #39280 /GetReadyTheDischarge: Charging ... HV=242 V 09:57:50 #39280 /GetReadyTheDischarge: Charging ... HV=285 V 09:57:50 #39280 /GetReadyTheDischarge: Charging ... HV=285 V 09:57:50 #39280 /GetReadyTheDischarge: Charging ... HV=285 V , Gas: H2, GasValve: 25.16 V 09:57:51 #39280 /GetReadyTheDischarge: Charging ... HV=329 V 09:57:51 #39280 /GetReadyTheDischarge: Charging ... HV=329 V 09:57:52 #39280 /GetReadyTheDischarge: Charging ... HV=369 V 09:57:52 #39280 /GetReadyTheDischarge: Charging ... HV=369 V 09:57:53 #39280 /GetReadyTheDischarge: Charging ... HV=369 V 09:57:53 #39280 /GetReadyTheDischarge: Charging ... HV=407 V 09:57:53 #39280 /GetReadyTheDischarge: Cd capacitor charging finished @ 407 V 09:57:54 #39280 /GetReadyTheDischarge: Charging ... HV=407 V 09:57:54 #39280 /GetReadyTheDischarge: Charging ... HV=446 V , Gas: H2, GasValve: 25.16 V 09:57:54 #39280 /GetReadyTheDischarge: Charging ... HV=446 V 09:57:55 #39280 /GetReadyTheDischarge: Charging ... HV=487 V 09:57:55 #39280 /GetReadyTheDischarge: Charging ... HV=15 V 09:57:56 #39280 /GetReadyTheDischarge: Charging ... HV=487 V 09:57:56 #39280 /GetReadyTheDischarge: Charging ... HV=527 V 09:57:57 #39280 /GetReadyTheDischarge: Charging ... HV=527 V 09:57:57 #39280 /GetReadyTheDischarge: Charging ... HV=565 V 09:57:57 #39280 /GetReadyTheDischarge: Charging ... HV=565 V 09:57:58 #39280 /GetReadyTheDischarge: Charging ... HV=565 V 09:57:58 #39280 /GetReadyTheDischarge: Charging ... HV=602 V 09:57:59 #39280 /GetReadyTheDischarge: Charging ... HV=602 V 09:57:59 #39280 /GetReadyTheDischarge: Charging ... HV=602 V 09:58:00 #39280 /GetReadyTheDischarge: Charging ... HV=637 V 09:58:00 #39280 /GetReadyTheDischarge: Charging ... HV=637 V 09:58:00 #39280 /GetReadyTheDischarge: Charging ... HV=673 V 09:58:01 #39280 /GetReadyTheDischarge: Charging ... HV=15 V 09:58:01 #39280 /GetReadyTheDischarge: Charging ... HV=673 V 09:58:02 #39280 /GetReadyTheDischarge: Charging ... HV=708 V 09:58:02 #39280 /GetReadyTheDischarge: Charging ... HV=708 V 09:58:03 #39280 /GetReadyTheDischarge: Charging ... HV=741 V 09:58:03 #39280 /GetReadyTheDischarge: Charging ... HV=741 V 09:58:03 #39280 /GetReadyTheDischarge: Charging ... HV=741 V 09:58:04 #39280 /GetReadyTheDischarge: Charging ... HV=771 V 09:58:04 #39280 /GetReadyTheDischarge: Charging ... HV=771 V 09:58:05 #39280 /GetReadyTheDischarge: Charging ... HV=802 V 09:58:05 #39280 /ChargingResistorsAllON: Diving into .. 09:58:05 #39280 /GetReadyTheDischarge: Bt capacitor charging finished @ 802 V 09:58:06 #39280 /ChargingResistorsAllON: Diving into .. 09:58:06 #39280 /GetReadyTheDischarge: Ascending from .. 09:58:06 #39280 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 09:58:08 #39280 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 09:58:08 #39280 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 09:58:08 #39280 /VacuumLog: Chamber: 18.10 mPa, 41.10 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 25.16 V 09:58:08 #39280 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 09:58:12 #39280 /VacuumLog: Chamber: 18.10 mPa, 41.20 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 25.16 V 09:58:16 #39280 /VacuumLog: Chamber: 18.10 mPa, 41.20 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 25.16 V 09:58:19 #39280 /Trigger: Going through .. 09:58:19 #39280 Discharge/HWTrigger: Going through .. 09:58:19 #39280 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 09:58:19 #39280 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 09:58:19 #39280 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 09:58:19 #39280 /VacuumLog: Chamber: 18.00 mPa, 41.10 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.16 V 09:58:23 #39280 /VacuumLog: Chamber: 16.30 mPa, 41.20 C, ForVacuum: 4.5 Pa, Gas: H2, GasValve: 25.16 V 09:58:24 #39280 /ChargingResistorsAllON: Diving into .. 09:58:26 #39280 /SecurePostDischargeState: Going through .. 09:58:26 #39280 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 09:58:27 #39280 /VacuumLog: Chamber: 2.02 mPa, 41.20 C, ForVacuum: 3.7 Pa, Gas: NULL, GasValve: 0.00 V 09:58:30 #39280 /VacuumLog: Chamber: 1.37 mPa, 41.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 09:58:31 #39280 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 09:58:34 #39280 /VacuumLog: Chamber: 1.32 mPa, 41.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 09:58:37 #39280 /VacuumLog: Chamber: 1.28 mPa, 41.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 09:58:41 #39280 /VacuumLog: Chamber: 1.24 mPa, 41.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 09:58:45 #39280 /VacuumLog: Chamber: 1.22 mPa, 41.20 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 09:58:48 #39280 /VacuumLog: Chamber: 1.21 mPa, 41.20 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:58:52 #39280 /VacuumLog: Chamber: 1.20 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:58:56 #39280 /VacuumLog: Chamber: 1.19 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:58:59 #39280 /VacuumLog: Chamber: 1.19 mPa, 41.20 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:03 #39280 /VacuumLog: Chamber: 1.18 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:07 #39280 /VacuumLog: Chamber: 1.18 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:09 #39280 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 09:59:10 #39280 /VacuumLog: Chamber: 1.18 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:14 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:18 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:21 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:25 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:29 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:32 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:36 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:39 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:41 #39280 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 09:59:43 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:47 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 09:59:48 #39280 /DischargeFunction: General Calling FinalDischargeOperations 09:59:50 #39280 /VacuumLog: Chamber: 1.17 mPa, 41.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V