10:47:00 #39282 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Plasma position stabilization 10:47:01 #39282 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 10:47:01 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.70 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 10:47:02 #39282 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 10:47:03 #39282 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 10:47:03 #39282 /GetReadyTheDischarge: Going with gas pressure 10 10:47:03 #39282 /GetReadyTheDischarge: Going with gas type H 10:47:03 #39282 /GetReadyTheDischarge: Discharge with Hydrogen requ10:47:03 #39282 /10:47:03 #39282 /GetReadyTheDischarge: Discharge with 10 mPa req10:47:03 #39282 /GetReadyTheDischarge: Discharge with Bt CW request 10:47:03 #39282 /GetReadyTheDischarge: Going with CD_orientation CW 10:47:03 #39282 /GetReadyTheDischarge: Discharge with CD CW request 10:47:04 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.80 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 21.11 V 10:47:08 #39282 /VacuumLog: Chamber: 1.10 mPa, 37.70 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 22.90 V 10:47:10 #39282 /GetReadyTheDischarge: Bt capacitor charging started 10:47:11 #39282 /VacuumLog: Chamber: 2.69 mPa, 37.80 C, ForVacuum: 1.4 Pa, Gas: H2, GasValve: 25.41 V 10:47:14 #39282 /GetReadyTheDischarge: Cd capacitor charging started 10:47:14 #39282 /ChargingResistorsAllOFF: Diving into .. 10:47:14 #39282 /GetReadyTheDischarge: U_Bt: 220, Hrana: 98 10:47:15 #39282 /GetReadyTheDischarge: U_Et: 220, Hrana: 98 10:47:15 #39282 /GetReadyTheDischarge: Charging ... HV=-13 V 10:47:15 #39282 /GetReadyTheDischarge: Charging ... HV=-13 V , Gas: H2, GasValve: 25.98 V 10:47:16 #39282 /GetReadyTheDischarge: Charging ... HV=-4 V 10:47:16 #39282 /GetReadyTheDischarge: Charging ... HV=-4 V 10:47:16 #39282 /GetReadyTheDischarge: Charging ... HV=39 V 10:47:17 #39282 /GetReadyTheDischarge: Charging ... HV=39 V 10:47:17 #39282 /GetReadyTheDischarge: Charging ... HV=39 V 10:47:18 #39282 /GetReadyTheDischarge: Charging ... HV=87 V 10:47:18 #39282 /GetReadyTheDischarge: Charging ... HV=87 V 10:47:19 #39282 /GetReadyTheDischarge: Charging ... HV=133 V 10:47:19 #39282 /GetReadyTheDischarge: Charging ... HV=133 V Gas: H2, GasValve: 24.89 V 10:47:19 #39282 /GetReadyTheDischarge: Charging ... HV=178 V 10:47:20 #39282 /GetReadyTheDischarge: Charging ... HV=178 V 10:47:20 #39282 /GetReadyTheDischarge: Charging ... HV=178 V 10:47:21 #39282 /GetReadyTheDischarge: Charging ... HV=224 V 10:47:21 #39282 /GetReadyTheDischarge: Bt capacitor charging finished @ 224 V 10:47:21 #39282 /ChargingResistorsAllON: Diving into .. 10:47:21 #39282 /GetReadyTheDischarge: Cd capacitor charging finished @ 224 V 10:47:22 #39282 /ChargingResistorsAllON: Diving into .. 10:47:22 #39282 /GetReadyTheDischarge: Ascending from .. 10:47:22 #39282 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 10:47:22 #39282 /VacuumLog: Chamber: 12.00 mPa, 37.70 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 24.89 V 10:47:24 #39282 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:47:24 #39282 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:47:25 #39282 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 10:47:26 #39282 /VacuumLog: Chamber: 11.90 mPa, 37.70 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 24.89 V 10:47:30 #39282 /VacuumLog: Chamber: 11.80 mPa, 37.70 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 24.89 V 10:47:33 #39282 /VacuumLog: Chamber: 11.70 mPa, 37.70 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 24.89 V 10:47:36 #39282 /Trigger: Going through .. 10:47:36 #39282 Discharge/HWTrigger: Going through .. 10:47:36 #39282 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 10:47:36 #39282 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 10:47:36 #39282 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 10:47:37 #39282 /VacuumLog: Chamber: 11.70 mPa, 37.70 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 24.89 V 10:47:40 #39282 /ChargingResistorsAllON: Diving into .. 10:47:41 #39282 /VacuumLog: Chamber: 11.60 mPa, 37.70 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 24.89 V 10:47:42 #39282 /SecurePostDischargeState: Going through .. 10:47:43 #39282 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 10:47:44 #39282 /VacuumLog: Chamber: 1.17 mPa, 37.70 C, ForVacuum: 2.35 Pa, Gas: NULL, GasValve: 0.00 V 10:47:48 #39282 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 10:47:48 #39282 /VacuumLog: Chamber: 1.08 mPa, 37.70 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 10:47:51 #39282 /VacuumLog: Chamber: 1.06 mPa, 37.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:47:55 #39282 /VacuumLog: Chamber: 1.06 mPa, 37.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:47:59 #39282 /VacuumLog: Chamber: 1.06 mPa, 37.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:02 #39282 /VacuumLog: Chamber: 1.06 mPa, 37.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:06 #39282 /VacuumLog: Chamber: 1.06 mPa, 37.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:10 #39282 /VacuumLog: Chamber: 1.06 mPa, 37.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:13 #39282 /VacuumLog: Chamber: 1.06 mPa, 37.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:17 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:17 #39282 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 10:48:21 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:24 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:28 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:31 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 10:48:35 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 10:48:39 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 10:48:42 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 10:48:44 #39282 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 10:48:46 #39282 /VacuumLog: Chamber: 1.07 mPa, 37.60 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 10:48:47 #39282 /DischargeFunction: General Calling FinalDischargeOperations