11:59:28 #39288 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Tomography intro + Timepix commissioning 11:59:29 #39288 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:59:30 #39288 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:59:31 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 11:59:31 #39288 /GetReadyTheDischarge: Going with gas pressure 10 11:59:31 #39288 /GetReadyTheDischarge: Going with gas type H 11:59:31 #39288 /GetReadyTheDischarge: Discharge with Hydrogen request 11:59:31 #39288 /GetReadyTheDischarge: Discharge with 10 mPa request 11:59:31 #39288 /GetReadyTheDischarge: Discharge with Bt CW request 11:59:31 #39288 /GetReadyTheDischarge: Going with CD_orientation CW 11:59:31 #39288 /GetReadyTheDischarge: Discharge with CD CW request 11:59:34 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 22.01 V 11:59:38 #39288 /VacuumLog: Chamber: 1.24 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 24.69 V 11:59:38 #39288 /GetReadyTheDischarge: Bt capacitor charging started 11:59:42 #39288 /VacuumLog: Chamber: 4.72 mPa, 35.20 C, ForVacuum: 1.55 Pa, Gas: H2, GasValve: 26.07 V 11:59:43 #39288 /GetReadyTheDischarge: Cd capacitor charging started 11:59:43 #39288 /ChargingResistorsAllOFF: Diving into .. 11:59:43 #39288 /GetReadyTheDischarge: U_Bt: 700, Hrana: 98 11:59:43 #39288 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 11:59:43 #39288 /GetReadyTheDischarge: Charging ... HV=-11 V 11:59:43 #39288 /GetReadyTheDischarge: Charging ... HV=18 V 11:59:44 #39288 /GetReadyTheDischarge: Charging ... HV=-11 V 11:59:44 #39288 /GetReadyTheDischarge: Charging ... HV=9 V 11:59:45 #39288 /GetReadyTheDischarge: Charging ... HV=9 V 11:59:45 #39288 /GetReadyTheDischarge: Charging ... HV=57 V 11:59:46 #39288 /GetReadyTheDischarge: Charging ... HV=57 V 11:59:46 #39288 /GetReadyTheDischarge: Charging ... HV=105 V 11:59:46 #39288 /GetReadyTheDischarge: Charging ... HV=105 V 11:59:47 #39288 /GetReadyTheDischarge: Charging ... HV=18 V 11:59:47 #39288 /GetReadyTheDischarge: Charging ... HV=151 V 11:59:48 #39288 /GetReadyTheDischarge: Charging ... HV=151 V 11:59:48 #39288 /GetReadyTheDischarge: Charging ... HV=197 V 11:59:49 #39288 /GetReadyTheDischarge: Charging ... HV=197 V 11:59:49 #39288 /VacuumLog: Chamber: 14.30 mPa, 35.20 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 25.91 V 11:59:49 #39288 /GetReadyTheDischarge: Charging ... HV=197 V 11:59:50 #39288 /GetReadyTheDischarge: Charging ... HV=243 V 11:59:50 #39288 /GetReadyTheDischarge: Charging ... HV=243 V 11:59:50 #39288 /GetReadyTheDischarge: Charging ... HV=287 V 11:59:51 #39288 /GetReadyTheDischarge: Charging ... HV=287 V 11:59:51 #39288 /GetReadyTheDischarge: Charging ... HV=287 V 11:59:52 #39288 /GetReadyTheDischarge: Charging ... HV=331 V 11:59:52 #39288 /GetReadyTheDischarge: Charging ... HV=331 V 11:59:53 #39288 /GetReadyTheDischarge: Charging ... HV=371 V , Gas: H2, GasValve: 25.91 V 11:59:53 #39288 /GetReadyTheDischarge: Charging ... HV=371 V 11:59:53 #39288 /GetReadyTheDischarge: Charging ... HV=18 V 11:59:54 #39288 /GetReadyTheDischarge: Charging ... HV=410 V 11:59:54 #39288 /GetReadyTheDischarge: Charging ... HV=410 V 11:59:55 #39288 /GetReadyTheDischarge: Charging ... HV=450 V 11:59:55 #39288 /GetReadyTheDischarge: Cd capacitor charging finished @ 450 V 11:59:55 #39288 /GetReadyTheDischarge: Charging ... HV=450 V 11:59:56 #39288 /GetReadyTheDischarge: Charging ... HV=488 V 11:59:56 #39288 /GetReadyTheDischarge: Charging ... HV=488 V 11:59:57 #39288 /GetReadyTheDischarge: Charging ... HV=488 V , Gas: H2, GasValve: 25.91 V 11:59:57 #39288 /GetReadyTheDischarge: Charging ... HV=528 V 11:59:57 #39288 /GetReadyTheDischarge: Charging ... HV=528 V 11:59:58 #39288 /GetReadyTheDischarge: Charging ... HV=567 V 11:59:58 #39288 /GetReadyTheDischarge: Charging ... HV=567 V 11:59:59 #39288 /GetReadyTheDischarge: Charging ... HV=567 V 11:59:59 #39288 /GetReadyTheDischarge: Charging ... HV=605 V 12:00:00 #39288 /GetReadyTheDischarge: Charging ... HV=605 V 12:00:00 #39288 /GetReadyTheDischarge: Charging ... HV=639 V 12:00:00 #39288 /GetReadyTheDischarge: Charging ... HV=18 V 12:00:01 #39288 /GetReadyTheDischarge: Charging ... HV=639 V 12:00:01 #39288 /GetReadyTheDischarge: Charging ... HV=677 V 12:00:02 #39288 /GetReadyTheDischarge: Charging ... HV=677 V 12:00:02 #39288 /GetReadyTheDischarge: Charging ... HV=677 V 12:00:03 #39288 /GetReadyTheDischarge: Charging ... HV=712 V 12:00:03 #39288 /ChargingResistorsAllON: Diving into .. 12:00:03 #39288 /GetReadyTheDischarge: Bt capacitor charging finished @ 712 V 12:00:03 #39288 /ChargingResistorsAllON: Diving into .. 12:00:04 #39288 /GetReadyTheDischarge: Ascending from .. .25 Pa, Gas: H2, GasValve: 25.91 V 12:00:04 #39288 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 12:00:05 #39288 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:00:05 #39288 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 12:00:06 #39288 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 12:00:07 #39288 /VacuumLog: Chamber: 15.00 mPa, 35.20 C, ForVacuum: 4.3 Pa, Gas: H2, GasValve: 25.91 V 12:00:11 #39288 /VacuumLog: Chamber: 15.10 mPa, 35.20 C, ForVacuum: 4.3 Pa, Gas: H2, GasValve: 25.91 V 12:00:14 #39288 /VacuumLog: Chamber: 15.20 mPa, 35.20 C, ForVacuum: 4.3 Pa, Gas: H2, GasValve: 25.91 V 12:00:17 #39288 /Trigger: Going through .. 12:00:17 #39288 Discharge/HWTrigger: Going through .. 12:00:17 #39288 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 12:00:17 #39288 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 12:00:17 #39288 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 12:00:18 #39288 /VacuumLog: Chamber: 15.30 mPa, 35.20 C, ForVacuum: 4.3 Pa, Gas: H2, GasValve: 25.91 V 12:00:21 #39288 /ChargingResistorsAllON: Diving into .. 12:00:22 #39288 /VacuumLog: Chamber: 15.60 mPa, 35.20 C, ForVacuum: 4.1 Pa, Gas: H2, GasValve: 25.91 V 12:00:24 #39288 /SecurePostDischargeState: Going through .. 12:00:24 #39288 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 12:00:25 #39288 /VacuumLog: Chamber: 1.31 mPa, 35.20 C, ForVacuum: 2.8 Pa, Gas: NULL, GasValve: 0.00 V 12:00:29 #39288 /VacuumLog: Chamber: 1.11 mPa, 35.20 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 12:00:29 #39288 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 12:00:33 #39288 /VacuumLog: Chamber: 1.07 mPa, 35.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 12:00:36 #39288 /VacuumLog: Chamber: 1.05 mPa, 35.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 12:00:40 #39288 /VacuumLog: Chamber: 1.04 mPa, 35.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:00:44 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:00:47 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:00:51 #39288 /VacuumLog: Chamber: 1.02 mPa, 35.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:00:54 #39288 /VacuumLog: Chamber: 1.02 mPa, 35.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:00:58 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:01:02 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:01:05 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:01:06 #39288 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 12:01:09 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 12:01:13 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:16 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:20 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:24 #39288 /VacuumLog: Chamber: 1.03 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:27 #39288 /VacuumLog: Chamber: 1.04 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:31 #39288 /VacuumLog: Chamber: 1.04 mPa, 35.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:35 #39288 /VacuumLog: Chamber: 1.04 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:38 #39288 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 12:01:38 #39288 /VacuumLog: Chamber: 1.04 mPa, 35.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:42 #39288 /VacuumLog: Chamber: 1.04 mPa, 35.20 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 12:01:45 #39288 /DischargeFunction: General Calling FinalDischargeOperations 12:01:46 #39288 /VacuumLog: Chamber: 1.04 mPa, 35.10 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V