16:41:48 #39415   Discharge/PrepareDischargeEnv@SHM:	Command Line Request: RE session               
16:41:48 #39415   /Broadcast:	**Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end               
16:41:50 #39415   /LogTheDeviceAction:	The Preionization action on stage with GetReadyTheDischarge         
16:41:50 #39415   /GetReadyTheDischarge:	Going with gas pressure 10               
16:41:50 #39415   /GetReadyTheDischarge:	Going with gas type H               
16:41:51 #39415   /GetReadyTheDischarge:	Discharge with Hydrogen request               
16:4116:41:51 #39415   /GetReadyTheDischarge:	Going with Bt_orientation CW               
16:41:51 #39415   /GetReadyTheDischarge:	Discharge with Bt CW request               
16:41:51 #39415   /GetReadyTheDischarge:	Going with CD_orientation CW               
16:41:51 #39415   /GetReadyTheDischarge:	Discharge with CD CW request               
16:41:54 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.00 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 21.94 V               
16:41:58 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.00 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 24.55 V               
16:41:58 #39415   /GetReadyTheDischarge:	Bt capacitor charging started               
16:42:01 #39415   /VacuumLog:	Chamber: 1.35 mPa,  37.00 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 26.29 V               
16:42:02 #39415   /GetReadyTheDischarge:	Cd capacitor charging started               
16:42:02 #39415   /ChargingResistorsAllOFF:	Diving into ..             
16:42:02 #39415   /GetReadyTheDischarge:	U_Bt: 1150, Hrana: 98               
16:42:02 #39415   /GetReadyTheDischarge:	U_Et: 700, Hrana: 98               
16:42:03 #39415   /GetReadyTheDischarge:	Charging ... HV=-8 V               
16:42:03 #39415   /GetReadyTheDischarge:	Charging ... HV=-8 V               
16:42:03 #39415   /GetReadyTheDischarge:	Charging ... HV=-8 V               
16:42:04 #39415   /GetReadyTheDischarge:	Charging ... HV=22 V               
16:42:04 #39415   /GetReadyTheDischarge:	Charging ... HV=22 V               
16:42:05 #39415   /GetReadyTheDischarge:	Charging ... HV=70 V               
16:42:05 #39415   /GetReadyTheDischarge:	Charging ... HV=70 V               
16:42:06 #39415   /GetReadyTheDischarge:	Charging ... HV=70 V               
16:42:06 #39415   /GetReadyTheDischarge:	Charging ... HV=116 V               
16:42:07 #39415   /GetReadyTheDischarge:	Charging ... HV=116 V               
16:42:07 #39415   /GetReadyTheDischarge:	Charging ... HV=163 V               
16:42:07 #39415   /GetReadyTheDischarge:	Charging ... HV=163 V               
16:42:08 #39415   /GetReadyTheDischarge:	Charging ... HV=163 V               
16:42:08 #39415   /GetReadyTheDischarge:	Charging ... HV=209 V               
16:42:08 #39415   /VacuumLog:	Chamber: 9.22 mPa,  37.00 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 28.50 V               
16:42:09 #39415   /GetReadyTheDischarge:	Charging ... HV=209 V               
16:42:09 #39415   /GetReadyTheDischarge:	Charging ... HV=254 V               
16:42:10 #39415   /GetReadyTheDischarge:	Charging ... HV=254 V               
16:42:10 #39415   /GetReadyTheDischarge:	Charging ... HV=254 V               
16:42:11 #39415   /GetReadyTheDischarge:	Charging ... HV=298 V               
16:42:11 #39415   /GetReadyTheDischarge:	Charging ... HV=298 V               
16:42:11 #39415   /GetReadyTheDischarge:	Charging ... HV=341 V               
16:42:12 #39415   /GetReadyTheDischarge:	Charging ... HV=341 V               
16:42:12 #39415   /GetReadyTheDischarge:	Charging ... HV=380 V               
, Gas: H2, GasValve: 28.50 V               
16:42:13 #39415   /GetReadyTheDischarge:	Charging ... HV=380 V               
16:42:13 #39415   /GetReadyTheDischarge:	Charging ... HV=380 V               
16:42:14 #39415   /GetReadyTheDischarge:	Charging ... HV=418 V               
16:42:14 #39415   /GetReadyTheDischarge:	Charging ... HV=418 V               
16:42:14 #39415   /GetReadyTheDischarge:	Charging ... HV=459 V               
16:42:15 #39415   /GetReadyTheDischarge:	Charging ... HV=459 V               
16:42:15 #39415   /GetReadyTheDischarge:	Charging ... HV=459 V               
16:42:16 #39415   /GetReadyTheDischarge:	Charging ... HV=495 V               
16:42:16 #39415   /GetReadyTheDischarge:	Charging ... HV=495 V               
, Gas: H2, GasValve: 28.50 V               
16:42:17 #39415   /GetReadyTheDischarge:	Charging ... HV=531 V               
16:42:17 #39415   /GetReadyTheDischarge:	Charging ... HV=531 V               
16:42:18 #39415   /GetReadyTheDischarge:	Charging ... HV=531 V               
16:42:18 #39415   /GetReadyTheDischarge:	Charging ... HV=567 V               
16:42:18 #39415   /GetReadyTheDischarge:	Charging ... HV=567 V               
16:42:19 #39415   /GetReadyTheDischarge:	Charging ... HV=601 V               
16:42:19 #39415   /GetReadyTheDischarge:	Charging ... HV=601 V               
16:42:20 #39415   /GetReadyTheDischarge:	Charging ... HV=601 V               
16:42:20 #39415   /GetReadyTheDischarge:	Charging ... HV=22 V               
16:42:21 #39415   /GetReadyTheDischarge:	Charging ... HV=632 V               
16:42:21 #39415   /GetReadyTheDischarge:	Charging ... HV=666 V               
16:42:21 #39415   /GetReadyTheDischarge:	Charging ... HV=666 V               
16:42:22 #39415   /GetReadyTheDischarge:	Charging ... HV=666 V               
16:42:22 #39415   /GetReadyTheDischarge:	Charging ... HV=699 V               
16:42:22 #39415   /GetReadyTheDischarge:	Cd slow PowSup               
16:42:23 #39415   /ChargingResistorsAllON:	Diving into ..             
16:42:23 #39415   /GetReadyTheDischarge:	Charging ... HV=728 V               
16:42:23 #39415   /GetReadyTheDischarge:	Cd capacitor charging finished @ 728 V               
16:42:23 #39415   /GetReadyTheDischarge:	Bt boost PowSup               
16:42:23 #39415   /ChargingResistorsAllOFF:	Diving into ..             
16:42:24 #39415   /GetReadyTheDischarge:	Charging ... HV=728 V               
16:42:24 #39415   /GetReadyTheDischarge:	Charging ... HV=728 V               
16:42:24 #39415   /GetReadyTheDischarge:	Charging ... HV=744 V               
16:42:25 #39415   /GetReadyTheDischarge:	Charging ... HV=744 V               
16:42:25 #39415   /GetReadyTheDischarge:	Charging ... HV=774 V               
16:42:26 #39415   /GetReadyTheDischarge:	Charging ... HV=774 V               
16:42:26 #39415   /GetReadyTheDischarge:	Charging ... HV=774 V               
16:42:27 #39415   /GetReadyTheDischarge:	Charging ... HV=805 V               
16:42:27 #39415   /GetReadyTheDischarge:	Charging ... HV=805 V               
16:42:27 #39415   /GetReadyTheDischarge:	Charging ... HV=837 V               
16:42:28 #39415   /GetReadyTheDischarge:	Charging ... HV=837 V               
16:42:28 #39415   /GetReadyTheDischarge:	Charging ... HV=837 V               
16:42:29 #39415   /GetReadyTheDischarge:	Charging ... HV=865 V               
16:42:29 #39415   /GetReadyTheDischarge:	Charging ... HV=865 V               
16:42:30 #39415   /GetReadyTheDischarge:	Charging ... HV=896 V               
16:42:30 #39415   /GetReadyTheDischarge:	Charging ... HV=896 V               
16:42:30 #39415   /GetReadyTheDischarge:	Charging ... HV=896 V               
16:42:31 #39415   /GetReadyTheDischarge:	Charging ... HV=924 V               
16:42:31 #39415   /GetReadyTheDischarge:	Charging ... HV=924 V               
16:42:32 #39415   /GetReadyTheDischarge:	Charging ... HV=953 V               
16:42:32 #39415   /GetReadyTheDischarge:	Charging ... HV=953 V               
16:42:33 #39415   /GetReadyTheDischarge:	Charging ... HV=953 V               
16:42:33 #39415   /GetReadyTheDischarge:	Charging ... HV=979 V               
16:42:33 #39415   /GetReadyTheDischarge:	Charging ... HV=979 V               
16:42:34 #39415   /GetReadyTheDischarge:	Charging ... HV=1005 V               
16:42:34 #39415   /VacuumLog:	Chamber: 23.10 mPa,  37.00 C, ForVacuum: 5.95 Pa, Gas: H2, GasValve: 28.50 V               
16:42:34 #39415   /GetReadyTheDischarge:	Charging ... HV=1005 V               
16:42:35 #39415   /GetReadyTheDischarge:	Charging ... HV=1005 V               
16:42:35 #39415   /GetReadyTheDischarge:	Charging ... HV=1030 V               
16:42:36 #39415   /GetReadyTheDischarge:	Charging ... HV=1030 V               
16:42:36 #39415   /GetReadyTheDischarge:	Charging ... HV=1056 V               
16:42:36 #39415   /GetReadyTheDischarge:	Charging ... HV=1056 V               
16:42:37 #39415   /GetReadyTheDischarge:	Charging ... HV=1056 V               
16:42:37 #39415   /GetReadyTheDischarge:	Charging ... HV=1081 V               
16:42:38 #39415   /GetReadyTheDischarge:	Charging ... HV=1081 V               
16:42:38 #39415   /VacuumLog:	Chamber: 23.40 mPa,  37.10 C, ForVacuum: 6.0 Pa, Gas: H2, GasValve: 28.50 V               
16:42:38 #39415   /GetReadyTheDischarge:	Charging ... HV=1081 V               
16:42:38 #39415   /GetReadyTheDischarge:	Charging ... HV=1104 V               
16:42:39 #39415   /GetReadyTheDischarge:	Charging ... HV=1104 V               
16:42:39 #39415   /GetReadyTheDischarge:	Charging ... HV=1126 V               
16:42:40 #39415   /GetReadyTheDischarge:	Charging ... HV=1126 V               
16:42:40 #39415   /GetReadyTheDischarge:	Charging ... HV=1126 V               
16:42:41 #39415   /GetReadyTheDischarge:	Charging ... HV=1147 V               
16:42:41 #39415   /GetReadyTheDischarge:	Bt slow PowSup               
16:42:41 #39415   /ChargingResistorsAllON:	Diving into ..             
16:42:41 #39415   /GetReadyTheDischarge:	Charging ... HV=1147 V               
16:42:42 #39415   /GetReadyTheDischarge:	Charging ... HV=1167 V               
 Gas: H2, GasValve: 28.50 V               
16:42:42 #39415   /ChargingResistorsAllON:	Diving into ..             
16:42:42 #39415   /GetReadyTheDischarge:	Bt capacitor charging finished @ 1167 V               
16:42:43 #39415   /ChargingResistorsAllON:	Diving into ..             
16:42:43 #39415   /GetReadyTheDischarge:	Ascending from ..             
16:42:43 #39415   /Broadcast:	**ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end               
16:42:45 #39415   TektrMSO56-a/LogTheDeviceAction:	The BasicDiagnostics action on stage with Arming         
16:42:45 #39415   TektrMSO56-a/LogTheDeviceAction:	The BasicDiagnostics action on stage with Arming         
16:42:45 #39415   TektrMSO58-a/LogTheDeviceAction:	The 21_RunAways_MT action on stage with Arming         
16:42:45 #39415   /VacuumLog:	Chamber: 24.30 mPa,  37.00 C, ForVacuum: 6.1 Pa, Gas: H2, GasValve: 28.50 V               
16:42:49 #39415   /Broadcast:	**ActualShot: ARMING@EVERYWHERE end               
16:42:49 #39415   /VacuumLog:	Chamber: 24.70 mPa,  37.00 C, ForVacuum: 6.15 Pa, Gas: H2, GasValve: 28.50 V               
16:42:52 #39415   /VacuumLog:	Chamber: 25.00 mPa,  37.10 C, ForVacuum: 6.2 Pa, Gas: H2, GasValve: 28.50 V               
16:42:56 #39415   /VacuumLog:	Chamber: 25.30 mPa,  37.00 C, ForVacuum: 6.2 Pa, Gas: H2, GasValve: 28.50 V               
16:42:59 #39415   /Trigger:	Going through ..             
16:42:59 #39415   Discharge/HWTrigger:	Going through ..             
16:42:59 #39415   Discharge/HWTrigger:	Going with trigger Tch3 - TBt 0               
16:42:59 #39415   Discharge/HWTrigger:	Going with trigger Tch4 - Tcd 1900               
16:42:59 #39415   Discharge/HWTrigger:	Going with trigger Tch5 - Tist 3100               
16:43:00 #39415   /VacuumLog:	Chamber: 25.60 mPa,  37.00 C, ForVacuum: 6.25 Pa, Gas: H2, GasValve: 28.50 V               
16:43:03 #39415   /VacuumLog:	Chamber: 25.60 mPa,  37.00 C, ForVacuum: 5.95 Pa, Gas: H2, GasValve: 28.50 V               
16:43:04 #39415   /ChargingResistorsAllON:	Diving into ..             
16:43:07 #39415   /VacuumLog:	Chamber: 2.10 mPa,  37.10 C, ForVacuum: 4.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:11 #39415   /VacuumLog:	Chamber: 1.58 mPa,  37.20 C, ForVacuum: 1.9 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:14 #39415   /VacuumLog:	Chamber: 1.86 mPa,  37.10 C, ForVacuum: 1.5 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:16 #39415   /SecurePostDischargeState:	Going through ..             
16:43:16 #39415   /Broadcast:	**ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end               
16:43:18 #39415   /VacuumLog:	Chamber: 1.64 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:21 #39415   /Broadcast:	**ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end               
16:43:21 #39415   /VacuumLog:	Chamber: 1.54 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:25 #39415   Papouch-Za/RawDataAcquiring:	Papouch-Za: Start of acquiring               
16:43:25 #39415   /VacuumLog:	Chamber: 1.48 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:29 #39415   /VacuumLog:	Chamber: 1.43 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:32 #39415   /VacuumLog:	Chamber: 1.40 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:36 #39415   /VacuumLog:	Chamber: 1.38 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:39 #39415   /VacuumLog:	Chamber: 1.36 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:43 #39415   /VacuumLog:	Chamber: 1.34 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:44 #39415   Papouch-Za/RawDataAcquiring:	Papouch-Za: End of acquiring               
16:43:47 #39415   /VacuumLog:	Chamber: 1.33 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:50 #39415   /VacuumLog:	Chamber: 1.32 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:54 #39415   /VacuumLog:	Chamber: 1.32 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:43:58 #39415   /VacuumLog:	Chamber: 1.31 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:01 #39415   /VacuumLog:	Chamber: 1.31 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:05 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:09 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:12 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:16 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:20 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:23 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:27 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:31 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:34 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:38 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:41 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:45 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:49 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:52 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:56 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:44:58 #39415   /Broadcast:	**ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end               
16:44:59 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:03 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:04 #39415   Papouch-St/RawDataAcquiring:	Papouch-St: Start of acquiring               
16:45:04 #39415   NIstandard/RawDataAcquiring:	NIstandard: Start of acquiring               
16:45:05 #39415   NIstandard/RawDataAcquiring:	NIstandard: End of acquiring               
16:45:07 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:10 #39415   Papouch-St/RawDataAcquiring:	Papouch-St: End of acquiring               
16:45:10 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:14 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:18 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:21 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:25 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:29 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:32 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:36 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:39 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:43 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:47 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:50 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:54 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:58 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:45:58 #39415   /Broadcast:	**ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end               
16:46:01 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:46:05 #39415   /DischargeFunction:	General Calling FinalDischargeOperations               
16:46:05 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V               
16:46:09 #39415   /VacuumLog:	Chamber: 1.30 mPa,  37.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V