16:35:14 #39517 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Dirigent service 16:35:14 #39517 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:35:15 #39517 /VacuumLog: Chamber: 1.76 mPa, 30.90 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 16:35:16 #39517 /GetReadyTheDischarge: Going with gas pressure 16 16:35:16 #39517 /GetReadyTheDischarge: Going with gas type H 16:35:16 #39517 /GetReadyTheDischarge: Discharge with Hydrogen request 16:35:16 #39517 /GetReadyTheDischarge: Discharge with 16 mPa request charge 16:35:16 #39517 /GetReadyTheDischarge: Diving into .. 16:35:16 #39517 /GetReadyTheDischarge: Going with Bt_orientation CW 16:35:16 #39517 /GetReadyTheDischarge: Discharge with Bt CW request 16:35:17 #39517 /GetReadyTheDischarge: Going with CD_orientation CW 16:35:17 #39517 /GetReadyTheDischarge: Discharge with CD CW request 16:35:19 #39517 /VacuumLog: Chamber: 1.76 mPa, 30.90 C, ForVacuum: 2.0 Pa, Gas: H2, GasValve: 23.46 V 16:35:23 #39517 /VacuumLog: Chamber: 1.76 mPa, 30.90 C, ForVacuum: 2.0 Pa, Gas: H2, GasValve: 26.31 V 16:35:23 #39517 /GetReadyTheDischarge: Bt capacitor charging started 16:35:26 #39517 /VacuumLog: Chamber: 2.41 mPa, 31.00 C, ForVacuum: 2.0 Pa, Gas: H2, GasValve: 30.56 V 16:35:28 #39517 /GetReadyTheDischarge: Cd capacitor charging started 16:35:28 #39517 /ChargingResistorsAllOFF: Diving into .. 16:35:28 #39517 /GetReadyTheDischarge: U_Bt: 900, Hrana: 98 16:35:28 #39517 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 16:35:28 #39517 /GetReadyTheDischarge: Charging ... HV=-14 V 16:35:29 #39517 /GetReadyTheDischarge: Charging ... HV=-7 V 16:35:29 #39517 /GetReadyTheDischarge: Charging ... HV=-7 V 16:35:30 #39517 /GetReadyTheDischarge: Charging ... HV=-7 V 16:35:30 #39517 /GetReadyTheDischarge: Charging ... HV=34 V a, Gas: H2, GasValve: 30.26 V 16:35:30 #39517 /GetReadyTheDischarge: Charging ... HV=34 V 16:35:31 #39517 /GetReadyTheDischarge: Charging ... HV=22 V 16:35:31 #39517 /GetReadyTheDischarge: Charging ... HV=83 V 16:35:32 #39517 /GetReadyTheDischarge: Charging ... HV=83 V 16:35:32 #39517 /GetReadyTheDischarge: Charging ... HV=129 V 16:35:33 #39517 /GetReadyTheDischarge: Charging ... HV=129 V 16:35:33 #39517 /GetReadyTheDischarge: Charging ... HV=175 V 16:35:34 #39517 /GetReadyTheDischarge: Charging ... HV=175 V 16:35:34 #39517 /GetReadyTheDischarge: Charging ... HV=222 V , Gas: H2, GasValve: 29.16 V 16:35:34 #39517 /GetReadyTheDischarge: Charging ... HV=22 V 16:35:35 #39517 /GetReadyTheDischarge: Charging ... HV=222 V 16:35:35 #39517 /GetReadyTheDischarge: Charging ... HV=266 V 16:35:36 #39517 /GetReadyTheDischarge: Charging ... HV=266 V 16:35:36 #39517 /GetReadyTheDischarge: Charging ... HV=311 V 16:35:37 #39517 /GetReadyTheDischarge: Charging ... HV=311 V 16:35:37 #39517 /GetReadyTheDischarge: Charging ... HV=311 V 16:35:37 #39517 /GetReadyTheDischarge: Charging ... HV=352 V 16:35:38 #39517 /GetReadyTheDischarge: Charging ... HV=352 V 16:35:38 #39517 /GetReadyTheDischarge: Charging ... HV=391 V 16:35:39 #39517 /GetReadyTheDischarge: Charging ... HV=391 V 16:35:39 #39517 /GetReadyTheDischarge: Charging ... HV=391 V 16:35:40 #39517 /GetReadyTheDischarge: Charging ... HV=430 V 16:35:40 #39517 /GetReadyTheDischarge: Charging ... HV=430 V 16:35:41 #39517 /GetReadyTheDischarge: Charging ... HV=470 V 16:35:41 #39517 /VacuumLog: Chamber: 13.80 mPa, 31.00 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 29.16 V 16:35:41 #39517 /GetReadyTheDischarge: Charging ... HV=470 V 16:35:41 #39517 /GetReadyTheDischarge: Charging ... HV=470 V 16:35:42 #39517 /GetReadyTheDischarge: Charging ... HV=22 V 16:35:42 #39517 /GetReadyTheDischarge: Charging ... HV=506 V 16:35:43 #39517 /GetReadyTheDischarge: Cd capacitor charging finished @ 506 V 16:35:43 #39517 /GetReadyTheDischarge: Charging ... HV=541 V 16:35:43 #39517 /GetReadyTheDischarge: Charging ... HV=541 V 16:35:44 #39517 /GetReadyTheDischarge: Charging ... HV=578 V 16:35:44 #39517 /GetReadyTheDischarge: Charging ... HV=578 V 16:35:45 #39517 /GetReadyTheDischarge: Charging ... HV=578 V , Gas: H2, GasValve: 29.16 V 16:35:45 #39517 /GetReadyTheDischarge: Charging ... HV=614 V 16:35:45 #39517 /GetReadyTheDischarge: Charging ... HV=614 V 16:35:46 #39517 /GetReadyTheDischarge: Charging ... HV=648 V 16:35:46 #39517 /GetReadyTheDischarge: Charging ... HV=648 V 16:35:47 #39517 /GetReadyTheDischarge: Charging ... HV=648 V 16:35:47 #39517 /GetReadyTheDischarge: Charging ... HV=686 V 16:35:47 #39517 /GetReadyTheDischarge: Charging ... HV=686 V 16:35:48 #39517 /GetReadyTheDischarge: Charging ... HV=721 V 16:35:48 #39517 /GetReadyTheDischarge: Charging ... HV=721 V Gas: H2, GasValve: 29.16 V 16:35:49 #39517 /GetReadyTheDischarge: Charging ... HV=721 V 16:35:49 #39517 /GetReadyTheDischarge: Charging ... HV=753 V 16:35:50 #39517 /GetReadyTheDischarge: Charging ... HV=753 V 16:35:50 #39517 /GetReadyTheDischarge: Charging ... HV=785 V 16:35:50 #39517 /GetReadyTheDischarge: Charging ... HV=785 V 16:35:51 #39517 /GetReadyTheDischarge: Charging ... HV=22 V 16:35:51 #39517 /GetReadyTheDischarge: Charging ... HV=816 V 16:35:52 #39517 /GetReadyTheDischarge: Charging ... HV=816 V 16:35:52 #39517 /GetReadyTheDischarge: Charging ... HV=816 V , Gas: H2, GasValve: 29.16 V 16:35:53 #39517 /GetReadyTheDischarge: Charging ... HV=847 V 16:35:53 #39517 /GetReadyTheDischarge: Charging ... HV=847 V 16:35:53 #39517 /GetReadyTheDischarge: Charging ... HV=847 V 16:35:54 #39517 /GetReadyTheDischarge: Charging ... HV=876 V 16:35:54 #39517 /GetReadyTheDischarge: Charging ... HV=876 V 16:35:55 #39517 /GetReadyTheDischarge: Charging ... HV=906 V 16:35:55 #39517 /ChargingResistorsAllON: Diving into .. 16:35:55 #39517 /GetReadyTheDischarge: Bt capacitor charging finished @ 906 V 16:35:56 #39517 /ChargingResistorsAllON: Diving into .. 16:35:56 #39517 /GetReadyTheDischarge: Ascending from .. 16:35:56 #39517 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:35:57 #39517 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:35:57 #39517 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:35:58 #39517 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:35:59 #39517 /VacuumLog: Chamber: 13.00 mPa, 31.00 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 29.16 V 16:36:03 #39517 /VacuumLog: Chamber: 12.90 mPa, 31.00 C, ForVacuum: 4.55 Pa, Gas: H2, GasValve: 29.16 V 16:36:06 #39517 /VacuumLog: Chamber: 12.80 mPa, 31.00 C, ForVacuum: 4.55 Pa, Gas: H2, GasValve: 29.16 V 16:36:08 #39517 /Trigger: Going through .. 16:36:08 #39517 Discharge/HWTrigger: Going through .. 16:36:08 #39517 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:36:08 #39517 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 16:36:08 #39517 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 16:36:10 #39517 /VacuumLog: Chamber: 12.70 mPa, 31.00 C, ForVacuum: 4.55 Pa, Gas: H2, GasValve: 29.16 V 16:36:12 #39517 /ChargingResistorsAllON: Diving into .. 16:36:14 #39517 /VacuumLog: Chamber: 13.40 mPa, 31.00 C, ForVacuum: 4.4 Pa, Gas: H2, GasValve: 0.00 V 16:36:17 #39517 /VacuumLog: Chamber: 2.22 mPa, 31.00 C, ForVacuum: 2.7 Pa, Gas: NULL, GasValve: 0.00 V 16:36:21 #39517 /VacuumLog: Chamber: 2.03 mPa, 31.00 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 16:36:25 #39517 /VacuumLog: Chamber: 1.94 mPa, 31.00 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 16:36:25 #39517 /SecurePostDischargeState: Going through .. 16:36:25 #39517 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:36:28 #39517 /VacuumLog: Chamber: 1.88 mPa, 31.00 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 16:36:30 #39517 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:36:32 #39517 /VacuumLog: Chamber: 1.85 mPa, 31.00 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 16:36:36 #39517 /VacuumLog: Chamber: 1.82 mPa, 31.00 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 16:36:39 #39517 /VacuumLog: Chamber: 1.80 mPa, 31.10 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 16:36:41 #39517 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:36:43 #39517 /VacuumLog: Chamber: 1.79 mPa, 31.10 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 16:36:46 #39517 /VacuumLog: Chamber: 1.78 mPa, 31.10 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 16:36:47 #39517 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:36:50 #39517 /VacuumLog: Chamber: 1.77 mPa, 31.10 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V 16:36:53 #39517 /DischargeFunction: General Calling FinalDischargeOperations 16:36:54 #39517 /VacuumLog: Chamber: 1.76 mPa, 31.10 C, ForVacuum: 1.95 Pa, Gas: NULL, GasValve: 0.00 V