13:38:57 #39593 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Training course for Ulm University 13:38:57 #39593 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 13:38:59 #39593 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 13:38:59 #39593 /VacuumLog: Chamber: 1.11 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:38:59 #39593 /GetReadyTheDischarge: Going with gas pressure 10 13:38:59 #39593 /GetReadyTheDischarge: Going with gas type H 13:38:59 #39593 /GetRe13:38:59 #39593 /GetReadyTheDischarge: Diving into .. 13:38:59 #39593 /GetReadyTheDischarge: Discharge with 10 mPa request 13:38:59 #39593 /GetReadyTheDischarge: Discharge with Bt CW request 13:38:59 #39593 /GetReadyTheDischarge: Going with CD_orientation CW 13:39:00 #39593 /GetReadyTheDischarge: Discharge with CD CW request 13:39:03 #39593 /VacuumLog: Chamber: 1.11 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: H2, GasValve: 21.99 V 13:39:06 #39593 /VacuumLog: Chamber: 1.11 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: H2, GasValve: 24.66 V 13:39:06 #39593 /GetReadyTheDischarge: Bt capacitor charging started 13:39:10 #39593 /VacuumLog: Chamber: 1.11 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: H2, GasValve: 26.44 V 13:39:11 #39593 /GetReadyTheDischarge: Cd capacitor charging started 13:39:11 #39593 /ChargingResistorsAllOFF: Diving into .. 13:39:11 #39593 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 13:39:11 #39593 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 13:39:11 #39593 /GetReadyTheDischarge: Charging ... HV=-15 V 13:39:12 #39593 /GetReadyTheDischarge: Charging ... HV=-12 V 13:39:12 #39593 /GetReadyTheDischarge: Charging ... HV=-12 V 13:39:13 #39593 /GetReadyTheDischarge: Charging ... HV=22 V 13:39:13 #39593 /GetReadyTheDischarge: Charging ... HV=22 V 13:39:13 #39593 /GetReadyTheDischarge: Charging ... HV=70 V 13:39:14 #39593 /GetReadyTheDischarge: Charging ... HV=70 V 13:39:14 #39593 /GetReadyTheDischarge: Charging ... HV=70 V 13:39:15 #39593 /GetReadyTheDischarge: Charging ... HV=116 V 13:39:15 #39593 /GetReadyTheDischarge: Charging ... HV=116 V 13:39:16 #39593 /GetReadyTheDischarge: Charging ... HV=162 V 13:39:16 #39593 /GetReadyTheDischarge: Charging ... HV=162 V 13:39:16 #39593 /GetReadyTheDischarge: Charging ... HV=162 V 13:39:17 #39593 /GetReadyTheDischarge: Charging ... HV=208 V 13:39:17 #39593 /VacuumLog: Chamber: 2.49 mPa, 38.60 C, ForVacuum: 1.8 Pa, Gas: H2, GasValve: 29.10 V 13:39:17 #39593 /GetReadyTheDischarge: Charging ... HV=208 V 13:39:18 #39593 /GetReadyTheDischarge: Charging ... HV=19 V 13:39:18 #39593 /GetReadyTheDischarge: Charging ... HV=253 V 13:39:19 #39593 /GetReadyTheDischarge: Charging ... HV=253 V 13:39:19 #39593 /GetReadyTheDischarge: Charging ... HV=297 V 13:39:20 #39593 /GetReadyTheDischarge: Charging ... HV=297 V 13:39:20 #39593 /GetReadyTheDischarge: Charging ... HV=339 V 13:39:20 #39593 /GetReadyTheDischarge: Charging ... HV=339 V 13:39:21 #39593 /GetReadyTheDischarge: Charging ... HV=339 V Gas: H2, GasValve: 29.10 V 13:39:21 #39593 /GetReadyTheDischarge: Charging ... HV=19 V 13:39:22 #39593 /GetReadyTheDischarge: Charging ... HV=379 V 13:39:22 #39593 /GetReadyTheDischarge: Charging ... HV=417 V 13:39:23 #39593 /GetReadyTheDischarge: Charging ... HV=417 V 13:39:23 #39593 /GetReadyTheDischarge: Charging ... HV=457 V 13:39:23 #39593 /GetReadyTheDischarge: Cd capacitor charging finished @ 457 V 13:39:24 #39593 /GetReadyTheDischarge: Charging ... HV=457 V 13:39:24 #39593 /GetReadyTheDischarge: Charging ... HV=457 V 13:39:24 #39593 /GetReadyTheDischarge: Charging ... HV=493 V 13:39:25 #39593 /GetReadyTheDischarge: Charging ... HV=493 V 13:39:25 #39593 /GetReadyTheDischarge: Charging ... HV=533 V 13:39:26 #39593 /GetReadyTheDischarge: Charging ... HV=533 V 13:39:26 #39593 /GetReadyTheDischarge: Charging ... HV=533 V 13:39:27 #39593 /GetReadyTheDischarge: Charging ... HV=572 V 13:39:27 #39593 /GetReadyTheDischarge: Charging ... HV=572 V 13:39:27 #39593 /GetReadyTheDischarge: Charging ... HV=607 V 13:39:28 #39593 /GetReadyTheDischarge: Charging ... HV=607 V 13:39:28 #39593 /GetReadyTheDischarge: Charging ... HV=607 V 13:39:29 #39593 /GetReadyTheDischarge: Charging ... HV=642 V 13:39:29 #39593 /GetReadyTheDischarge: Charging ... HV=642 V 13:39:30 #39593 /GetReadyTheDischarge: Charging ... HV=679 V 13:39:30 #39593 /GetReadyTheDischarge: Charging ... HV=679 V 13:39:30 #39593 /GetReadyTheDischarge: Charging ... HV=679 V 13:39:31 #39593 /GetReadyTheDischarge: Charging ... HV=714 V 13:39:31 #39593 /GetReadyTheDischarge: Charging ... HV=714 V 13:39:32 #39593 /GetReadyTheDischarge: Charging ... HV=714 V 13:39:32 #39593 /GetReadyTheDischarge: Charging ... HV=747 V 13:39:33 #39593 /GetReadyTheDischarge: Charging ... HV=747 V 13:39:33 #39593 /GetReadyTheDischarge: Charging ... HV=778 V 13:39:33 #39593 /GetReadyTheDischarge: Charging ... HV=778 V 13:39:34 #39593 /GetReadyTheDischarge: Charging ... HV=778 V 13:39:34 #39593 /GetReadyTheDischarge: Charging ... HV=808 V 13:39:34 #39593 /ChargingResistorsAllON: Diving into .. 13:39:35 #39593 /GetReadyTheDischarge: Bt capacitor charging finished @ 808 V 13:39:35 #39593 /ChargingResistorsAllON: Diving into .. 13:39:35 #39593 /GetReadyTheDischarge: Ascending from .. 13:39:35 #39593 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 13:39:35 #39593 /VacuumLog: Chamber: 4.02 mPa, 38.60 C, ForVacuum: 2.45 Pa, Gas: H2, GasValve: 29.10 V 13:39:37 #39593 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 13:39:37 #39593 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 13:39:37 #39593 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 13:39:39 #39593 /VacuumLog: Chamber: 4.18 mPa, 38.50 C, ForVacuum: 2.5 Pa, Gas: H2, GasValve: 29.10 V 13:39:43 #39593 /VacuumLog: Chamber: 4.66 mPa, 38.60 C, ForVacuum: 2.6 Pa, Gas: H2, GasValve: 29.10 V 13:39:46 #39593 /VacuumLog: Chamber: 4.80 mPa, 38.60 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 29.10 V 13:39:48 #39593 /Trigger: Going through .. 13:39:48 #39593 Discharge/HWTrigger: Going through .. 13:39:48 #39593 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 13:39:48 #39593 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 13:39:48 #39593 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 13:39:50 #39593 /VacuumLog: Chamber: 4.83 mPa, 38.60 C, ForVacuum: 2.8 Pa, Gas: H2, GasValve: 29.10 V 13:39:52 #39593 /ChargingResistorsAllON: Diving into .. 13:39:53 #39593 /VacuumLog: Chamber: 4.98 mPa, 38.50 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 0.00 V 13:39:57 #39593 /VacuumLog: Chamber: 1.24 mPa, 38.60 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 13:40:01 #39593 /VacuumLog: Chamber: 1.19 mPa, 38.60 C, ForVacuum: 1.65 Pa, Gas: NULL, GasValve: 0.00 V 13:40:04 #39593 /VacuumLog: Chamber: 1.17 mPa, 38.60 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 13:40:05 #39593 /SecurePostDischargeState: Going through .. 13:40:05 #39593 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 13:40:08 #39593 /VacuumLog: Chamber: 1.15 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:10 #39593 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 13:40:12 #39593 /VacuumLog: Chamber: 1.15 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:15 #39593 /VacuumLog: Chamber: 1.14 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:19 #39593 /VacuumLog: Chamber: 1.13 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:22 #39593 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 13:40:23 #39593 /VacuumLog: Chamber: 1.13 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:26 #39593 /VacuumLog: Chamber: 1.13 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:30 #39593 /VacuumLog: Chamber: 1.13 mPa, 38.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:34 #39593 /VacuumLog: Chamber: 1.13 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:37 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:41 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:44 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:48 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:52 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:55 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:40:59 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:41:03 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:41:05 #39593 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 13:41:06 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:41:10 #39593 /VacuumLog: Chamber: 1.12 mPa, 38.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 13:41:12 #39593 /DischargeFunction: General Calling FinalDischargeOperations