Golem shot: 4027

2010-11-25 - 201120

Basic parameters:
  • Chamber pressure pchamber : 1.77->1.77 mPa (vacuum shot)
  • Chamber temperature: grad C
  • CBt capacitors (23 mF) charged to: V
  • CBD capacitors (3.6 mF) charged to: V, triggered ms after Bt
  • CCD capacitors (11.3 mF) charged to: V, triggered ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 387 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.85 over 8.09 to 16.94 [ms]
  • Mean toroidal magnetic field Bt: 0.146 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 7.2 V
  • Break down voltage: 9.5 V
  • Plasma total charge: 11.5 C
  • Ohmic heating power: 10.1 kW
  • Q edge: 9.4
  • Central electron temperature: 30.1 eV

Thanks to the specific help and