Golem shot: 4040

2010-11-25 - 211901

Basic parameters:
  • Chamber pressure pchamber : 1.75->29.53 mPa (request: 20 mPa)
  • Chamber temperature: 11 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 5,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 4491 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 10.86 over 7.52 to 18.38 [ms]
  • Mean toroidal magnetic field Bt: 0.169 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: 7.0 V
  • Break down voltage: 9.6 V
  • Plasma total charge: 9.5 C
  • Ohmic heating power: 9.1 kW
  • Q edge: 11.7
  • Central electron temperature: 29.2 eV

NI


MirnovCoils


Thanks to the specific help and