Golem shot: 4059

2010-11-26 - 100109

Basic parameters:
  • Chamber pressure pchamber : 1.84->22.92 mPa (request: 20 mPa)
  • Chamber temperature: 7 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 5064 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.03 over 8.22 to 17.25 [ms]
  • Mean toroidal magnetic field Bt: 0.152 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 7.1 V
  • Break down voltage: 9.5 V
  • Plasma total charge: 11.6 C
  • Ohmic heating power: 9.9 kW
  • Q edge: 9.8
  • Central electron temperature: 30.4 eV

MirnovCoils


Thanks to the specific help and