Basic parameters:
- Chamber pressure pchamber : 1.80->25.72 mPa
(request: 20 mPa)
- Chamber temperature: 10 grad C
- CBt capacitors (23 mF) charged to: 600 V
- CBD capacitors (3.6 mF) charged to: 100 V, triggered 5,0 ms after Bt
- CCD capacitors (11.3 mF) charged to: 400 V, triggered 5,0 ms after Bt
- charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
- Time since session beginning: 1862 s
Data (sampling interval Ts=100 kHz):
|
Plasma parameters:
- Plasma life from 10.78 over 10.09 to 20.87 [ms]
- Mean toroidal magnetic field Bt: 0.169 T
- Mean plasma current: 2.1 kA
- Mean Uloop: 6.0 V
- Break down voltage: 9.6 V
- Plasma total charge: 21.0 C
- Ohmic heating power: 12.6 kW
- Q edge: 7.3
- Central electron temperature: 44.6 eV
|