The session survey for the 23-05-23

(psql command: SELECT shot_no,"X_discharge_command" FROM operation.discharges WHERE session_id LIKE "41886 %" ORDER BY shot_no ASC LIMIT 200)

Mission="Run aways diagnostics: Radiometer, Scintillation probes"

Staff="Vladislav I., Cerovsky J. & Dirigent"

#41886 (23-05-23 11:51:34)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=500,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='off',U_heater=0,U_accel=0" --infrastructure.workinggas "S_mode='U_v',S_gas='H',U_v=20.5,p_H=-1" --infrastructure.positionstabilization "main_switch='on',vertical_switch='on',vertical_waveform='3000,0;7000,0;8000,-20;30000,0',radial_switch='on',radial_waveform='2000,0;3000,0;9000,-20;30000,0'" --diagnostics.limitermirnovcoils "vacuum_shot=41794" --diagnostics.scintillationprobes "U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600" --comment "Master standard discharge"




















#41887 (23-05-23 11:57:13)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=500,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='off',U_heater=0,U_accel=0" --infrastructure.workinggas "S_mode='U_v',S_gas='H',U_v=21,p_H=-1" --infrastructure.positionstabilization "main_switch='on',vertical_switch='on',vertical_waveform='3000,0;7000,0;8000,-20;30000,0',radial_switch='on',radial_waveform='2000,0;3000,0;9000,-20;30000,0'" --diagnostics.limitermirnovcoils "vacuum_shot=41794" --diagnostics.scintillationprobes "U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600" --comment "Master standard discharge"