16:32:03 #41901 PingAllDevices: 16:32:04 #41901 CheckAbilityToMakeDischarge: Ping OK 16:32:04 #41901 LogTheFunctionAction: The Function PrepareEnvironment@SHM on stage .. 16:32:04 #41901 PrepareDischargeEnv@SHM: ./Dirigent.sh \n--discharge --operation.discharge "style='standard',vacuum_shot='-1'" \n--infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,O_Bt='CW',U_cd=700,t_cd=1000,O_cd='CW'" \n--infrastructure.preionization "S_device='HotCathode',SW_main='off',U_heater=0,U_accel=0" \n--infrastructure.workinggas "S_mode='U_v',S_gas='H',U_v=20.0,p_H=-1" \n--infrastructure.positionstabilization "main_switch='on',vertical_switch='on',vertical_waveform='3000,0;7000,-5;8000,-20;30000,0',radial_switch='on',radial_waveform='2000,0;3000,-5;5000,-20;30000,0'" \n--diagnostics.scintillationprobes 16:32:04 #41902 PrepareDischargeEnv@SHM: Command Line Request: Run aways diagnostics: Radiometer, Scintillation probes 16:32:05 #41902 GetReadyTheDischarge: Going with gas pressure -1 16:32:05 #41902 GetReadyTheDischarge: Going with gas type H 16:32:05 #41902 SetUpHV@NIMchannel: HV@NIM setup 600 @ 0 16:32:05 #41902 SetUpHV@NIMchannel: HV@NIM setup 650 @ 1 16:32:06 #41902 GetReadyTheDischarge: Diving into .. 16:32:06 #41902 GetReadyTheDischarge: Discharge with Bt CW request 16:32:06 #41902 GetReadyTheDischarge: Discharge with CD CW request 16:32:06 #41902 SetUpHV@NIMchannel: HV@NIM setup 600 @ 3 16:32:06 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.50 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:10 #41902 VacuumLog: Chamber: p=4.28/-1 mPa,T=31.50 C,ForVacuum: 2.75 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:12 #41902 GetReadyTheDischarge: We have got 20.0 V for -1 mPa request 16:32:13 #41902 VacuumLog: Chamber: p=7.07/-1 mPa,T=31.50 C,ForVacuum: 3.45 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:13 #41902 GetReadyTheDischarge: Bt capacitor charging started 16:32:17 #41902 VacuumLog: Chamber: p=8.66/-1 mPa,T=31.60 C,ForVacuum: 3.8 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:18 #41902 GetReadyTheDischarge: Cd capacitor charging started 16:32:18 #41902 ChargingResistorsAllOFF: Diving into .. 16:32:18 #41902 GetReadyTheDischarge: U_Bt: 1300, Hrana: 98 16:32:18 #41902 GetReadyTheDischarge: U_Et: 700, Hrana: 98 16:32:18 #41902 GetReadyTheDischarge: Charging ... HV=-14 V 16:32:19 #41902 GetReadyTheDischarge: Charging ... HV=-14 V 16:32:19 #41902 GetReadyTheDischarge: Charging ... HV=-3 V 16:32:20 #41902 GetReadyTheDischarge: Charging ... HV=-3 V 16:32:20 #41902 GetReadyTheDischarge: Charging ... HV=41 V 16:32:20 #41902 VacuumLog: Chamber: p=9.01/-1 mPa,T=31.60 C,ForVacuum: 3.85 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:21 #41902 GetReadyTheDischarge: Charging ... HV=41 V 16:32:21 #41902 GetReadyTheDischarge: Charging ... HV=41 V 16:32:22 #41902 GetReadyTheDischarge: Charging ... HV=89 V 16:32:22 #41902 GetReadyTheDischarge: Charging ... HV=89 V 16:32:22 #41902 GetReadyTheDischarge: Charging ... HV=134 V 16:32:23 #41902 GetReadyTheDischarge: Charging ... HV=134 V 16:32:23 #41902 GetReadyTheDischarge: Charging ... HV=22 V 16:32:24 #41902 GetReadyTheDischarge: Charging ... HV=181 V 16:32:24 #41902 GetReadyTheDischarge: Charging ... HV=181 V Pa, Gas: NULL,GasValve: U=20.00 V 16:32:25 #41902 GetReadyTheDischarge: Charging ... HV=226 V 16:32:25 #41902 GetReadyTheDischarge: Charging ... HV=226 V 16:32:25 #41902 GetReadyTheDischarge: Charging ... HV=270 V 16:32:26 #41902 GetReadyTheDischarge: Charging ... HV=270 V 16:32:26 #41902 GetReadyTheDischarge: Charging ... HV=270 V 16:32:27 #41902 GetReadyTheDischarge: Charging ... HV=314 V 16:32:27 #41902 GetReadyTheDischarge: Charging ... HV=314 V 16:32:28 #41902 GetReadyTheDischarge: Charging ... HV=354 V 16:32:28 #41902 GetReadyTheDischarge: Charging ... HV=354 V 16:32:29 #41902 GetReadyTheDischarge: Charging ... HV=354 V 16:32:29 #41902 GetReadyTheDischarge: Charging ... HV=393 V 16:32:29 #41902 GetReadyTheDischarge: Charging ... HV=393 V 16:32:30 #41902 GetReadyTheDischarge: Charging ... HV=431 V 16:32:30 #41902 GetReadyTheDischarge: Charging ... HV=431 V 16:32:31 #41902 GetReadyTheDischarge: Charging ... HV=431 V 16:32:31 #41902 VacuumLog: Chamber: p=9.27/-1 mPa,T=31.50 C,ForVacuum: 3.85 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:31 #41902 GetReadyTheDischarge: Charging ... HV=471 V 16:32:32 #41902 GetReadyTheDischarge: Charging ... HV=471 V 16:32:32 #41902 GetReadyTheDischarge: Charging ... HV=506 V 16:32:32 #41902 GetReadyTheDischarge: Charging ... HV=506 V 16:32:33 #41902 GetReadyTheDischarge: Charging ... HV=506 V 16:32:33 #41902 GetReadyTheDischarge: Charging ... HV=541 V 16:32:34 #41902 GetReadyTheDischarge: Charging ... HV=541 V 16:32:34 #41902 GetReadyTheDischarge: Charging ... HV=576 V 16:32:35 #41902 GetReadyTheDischarge: Charging ... HV=576 V Pa, Gas: NULL,GasValve: U=20.00 V 16:32:35 #41902 GetReadyTheDischarge: Charging ... HV=576 V 16:32:36 #41902 GetReadyTheDischarge: Charging ... HV=609 V 16:32:36 #41902 GetReadyTheDischarge: Charging ... HV=609 V 16:32:36 #41902 GetReadyTheDischarge: Charging ... HV=639 V 16:32:37 #41902 GetReadyTheDischarge: Charging ... HV=639 V 16:32:37 #41902 GetReadyTheDischarge: Charging ... HV=674 V 16:32:38 #41902 GetReadyTheDischarge: Charging ... HV=674 V 16:32:38 #41902 GetReadyTheDischarge: Charging ... HV=674 V 16:32:39 #41902 GetReadyTheDischarge: Charging ... HV=705 V 16:32:39 #41902 GetReadyTheDischarge: Cd capacitor charging finished @ 705 V 16:32:39 #41902 GetReadyTheDischarge: Charging ... HV=705 V 16:32:40 #41902 GetReadyTheDischarge: Charging ... HV=736 V 16:32:40 #41902 GetReadyTheDischarge: Charging ... HV=736 V 16:32:40 #41902 GetReadyTheDischarge: Charging ... HV=736 V 16:32:41 #41902 GetReadyTheDischarge: Charging ... HV=767 V 16:32:41 #41902 GetReadyTheDischarge: Charging ... HV=767 V 16:32:42 #41902 GetReadyTheDischarge: Charging ... HV=798 V 16:32:42 #41902 GetReadyTheDischarge: Charging ... HV=798 V 16:32:42 #41902 GetReadyTheDischarge: Charging ... HV=798 V 16:32:43 #41902 GetReadyTheDischarge: Charging ... HV=829 V 16:32:43 #41902 GetReadyTheDischarge: Charging ... HV=829 V 16:32:44 #41902 GetReadyTheDischarge: Charging ... HV=857 V 16:32:44 #41902 GetReadyTheDischarge: Charging ... HV=857 V 16:32:45 #41902 GetReadyTheDischarge: Charging ... HV=857 V 16:32:45 #41902 GetReadyTheDischarge: Charging ... HV=888 V 16:32:45 #41902 GetReadyTheDischarge: Charging ... HV=888 V 16:32:46 #41902 GetReadyTheDischarge: Charging ... HV=915 V 16:32:46 #41902 GetReadyTheDischarge: Charging ... HV=915 V 16:32:47 #41902 GetReadyTheDischarge: Charging ... HV=915 V 16:32:47 #41902 GetReadyTheDischarge: Charging ... HV=944 V 16:32:48 #41902 GetReadyTheDischarge: Charging ... HV=944 V 16:32:48 #41902 GetReadyTheDischarge: Charging ... HV=944 V 16:32:48 #41902 GetReadyTheDischarge: Charging ... HV=970 V 16:32:49 #41902 VacuumLog: Chamber: p=9.50/-1 mPa,T=31.50 C,ForVacuum: 3.9 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:49 #41902 GetReadyTheDischarge: Charging ... HV=970 V 16:32:49 #41902 GetReadyTheDischarge: Charging ... HV=995 V 16:32:50 #41902 GetReadyTheDischarge: Charging ... HV=995 V 16:32:50 #41902 GetReadyTheDischarge: Charging ... HV=995 V 16:32:51 #41902 GetReadyTheDischarge: Charging ... HV=1019 V 16:32:51 #41902 GetReadyTheDischarge: Charging ... HV=1019 V 16:32:51 #41902 GetReadyTheDischarge: Charging ... HV=1046 V 16:32:52 #41902 GetReadyTheDischarge: Charging ... HV=1046 V 16:32:52 #41902 GetReadyTheDischarge: Charging ... HV=1046 V 16:32:52 #41902 VacuumLog: Chamber: p=9.54/-1 mPa,T=31.50 C,ForVacuum: 3.9 Pa, Gas: NULL,GasValve: U=20.00 V 16:32:53 #41902 GetReadyTheDischarge: Charging ... HV=1071 V 16:32:53 #41902 GetReadyTheDischarge: Charging ... HV=1071 V 16:32:53 #41902 GetReadyTheDischarge: Charging ... HV=1093 V 16:32:54 #41902 GetReadyTheDischarge: Charging ... HV=1093 V 16:32:54 #41902 GetReadyTheDischarge: Charging ... HV=1093 V 16:32:55 #41902 GetReadyTheDischarge: Charging ... HV=1115 V 16:32:55 #41902 GetReadyTheDischarge: Charging ... HV=1115 V 16:32:56 #41902 GetReadyTheDischarge: Charging ... HV=1136 V 16:32:56 #41902 GetReadyTheDischarge: Charging ... HV=1136 V a, Gas: NULL,GasValve: U=20.00 V 16:32:56 #41902 GetReadyTheDischarge: Charging ... HV=1136 V 16:32:57 #41902 GetReadyTheDischarge: Charging ... HV=1157 V 16:32:57 #41902 GetReadyTheDischarge: Charging ... HV=1157 V 16:32:58 #41902 GetReadyTheDischarge: Charging ... HV=1177 V 16:32:58 #41902 GetReadyTheDischarge: Charging ... HV=1177 V 16:32:59 #41902 GetReadyTheDischarge: Charging ... HV=1177 V 16:32:59 #41902 GetReadyTheDischarge: Charging ... HV=1199 V 16:32:59 #41902 GetReadyTheDischarge: Charging ... HV=1199 V 16:33:00 #41902 GetReadyTheDischarge: Charging ... HV=1217 V a, Gas: NULL,GasValve: U=20.00 V 16:33:00 #41902 GetReadyTheDischarge: Charging ... HV=1217 V 16:33:01 #41902 GetReadyTheDischarge: Charging ... HV=1217 V 16:33:01 #41902 GetReadyTheDischarge: Charging ... HV=1235 V 16:33:01 #41902 GetReadyTheDischarge: Charging ... HV=1235 V 16:33:02 #41902 GetReadyTheDischarge: Charging ... HV=1235 V 16:33:02 #41902 GetReadyTheDischarge: Charging ... HV=1253 V 16:33:03 #41902 GetReadyTheDischarge: Charging ... HV=1253 V 16:33:03 #41902 GetReadyTheDischarge: Charging ... HV=1270 V 16:33:04 #41902 GetReadyTheDischarge: Charging ... HV=1270 V 16:33:04 #41902 GetReadyTheDischarge: Charging ... HV=1270 V 16:33:04 #41902 GetReadyTheDischarge: Charging ... HV=1287 V 16:33:05 #41902 GetReadyTheDischarge: Bt slow PowSup 16:33:05 #41902 ChargingResistorsAllON: Diving into .. 16:33:05 #41902 GetReadyTheDischarge: Charging ... HV=1287 V 16:33:05 #41902 GetReadyTheDischarge: Charging ... HV=1305 V 16:33:06 #41902 ChargingResistorsAllON: Diving into .. 16:33:06 #41902 GetReadyTheDischarge: Bt capacitor charging finished @ 1305 V 16:33:07 #41902 VacuumLog: Chamber: p=9.72/-1 mPa,T=31.50 C,ForVacuum: 3.95 Pa, Gas: NULL,GasValve: U=20.00 V 16:33:07 #41902 ChargingResistorsAllON: Diving into .. 16:33:07 #41902 GetReadyTheDischarge: Ascending from .. 16:33:07 #41902 LogTheDeviceAction: The TektrMSO56-a.sh action on stage with Arming 16:33:07 #41902 LogTheDeviceAction: The TektrMSO58-a.sh action on stage with Arming 16:33:10 #41902 VacuumLog: Chamber: p=9.76/-1 mPa,T=31.50 C,ForVacuum: 3.95 Pa, Gas: NULL,GasValve: U=20.00 V 16:33:14 #41902 VacuumLog: Chamber: p=9.81/-1 mPa,T=31.50 C,ForVacuum: 3.95 Pa, Gas: NULL,GasValve: U=20.00 V 16:33:17 #41902 VacuumLog: Chamber: p=9.85/-1 mPa,T=31.50 C,ForVacuum: 3.95 Pa, Gas: NULL,GasValve: U=20.00 V 16:33:21 #41902 VacuumLog: Chamber: p=9.89/-1 mPa,T=31.50 C,ForVacuum: 3.95 Pa, Gas: NULL,GasValve: U=20.00 V 16:33:22 #41902 Trigger: Going through .. 16:33:22 #41902 HWTrigger: Going through .. 16:33:22 #41902 HWTrigger: Going with trigger Tch3 - TBt 0 16:33:22 #41902 HWTrigger: Going with trigger Tch4 - Tcd 1000 16:33:24 #41902 VacuumLog: Chamber: p=9.93/-1 mPa,T=31.50 C,ForVacuum: 3.95 Pa, Gas: NULL,GasValve: U=20.00 V 16:33:25 #41902 SecurePostDischargeState: Going through .. 16:33:26 #41902 ChargingResistorsAllON: Diving into .. 16:33:28 #41902 VacuumLog: Chamber: p=3.11/-1 mPa,T=31.60 C,ForVacuum: 2.4 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:31 #41902 VacuumLog: Chamber: p=1.48/-1 mPa,T=31.60 C,ForVacuum: 1.6 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:34 #41902 SecurePostDischargeState: Going through .. 16:33:35 #41902 VacuumLog: Chamber: p=1.24/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:38 #41902 VacuumLog: Chamber: p=1.15/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:39 #41902 RawDataAcquiring: 2NI_PC-StepMal: Start of acquiring 16:33:40 #41902 RawDataAcquiring: 2NI_PC-StepMal: End of acquiring 16:33:42 #41902 VacuumLog: Chamber: p=1.10/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:46 #41902 VacuumLog: Chamber: p=1.06/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:47 #41902 RawDataAcquiring: 2NI_PC-VoSv: End of acquiring 16:33:49 #41902 VacuumLog: Chamber: p=1.04/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:53 #41902 VacuumLog: Chamber: p=1.02/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:33:56 #41902 VacuumLog: Chamber: p=1.00/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:00 #41902 VacuumLog: Chamber: p=0.98/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:03 #41902 VacuumLog: Chamber: p=0.97/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:07 #41902 VacuumLog: Chamber: p=0.96/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:11 #41902 VacuumLog: Chamber: p=0.95/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:14 #41902 VacuumLog: Chamber: p=0.94/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:18 #41902 VacuumLog: Chamber: p=0.94/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:21 #41902 VacuumLog: Chamber: p=0.93/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:25 #41902 VacuumLog: Chamber: p=0.93/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:28 #41902 VacuumLog: Chamber: p=0.92/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:32 #41902 VacuumLog: Chamber: p=0.92/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:35 #41902 VacuumLog: Chamber: p=0.91/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:39 #41902 VacuumLog: Chamber: p=0.91/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:43 #41902 VacuumLog: Chamber: p=0.91/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:46 #41902 VacuumLog: Chamber: p=0.91/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:50 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:53 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:34:57 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:35:00 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:35:04 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:35:08 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:35:11 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.50 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V 16:35:15 #41902 VacuumLog: Chamber: p=0.90/-1 mPa,T=31.60 C,ForVacuum: 1.5 Pa, Gas: NULL,GasValve: U=0.00 V