Golem shot: 4230

2010-12-02 - 155551

Basic parameters:
  • Chamber pressure pchamber : 1.79->20.58 mPa (request: 20 mPa)
  • Chamber temperature: 8 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 182 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.76 over 9.04 to 17.8 [ms]
  • Mean toroidal magnetic field Bt: 0.146 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: 8.7 V
  • Break down voltage: 10.6 V
  • Plasma total charge: 17.2 C
  • Ohmic heating power: 16.5 kW
  • Q edge: 6.9
  • Central electron temperature: 32.6 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and