Golem shot: 4236

2010-12-02 - 173339

Basic parameters:
  • Chamber pressure pchamber : 20.58->20.35 mPa (request: 20 mPa)
  • Chamber temperature: 11 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 75 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 7,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6075 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.32 over 8.56 to 16.88 [ms]
  • Mean toroidal magnetic field Bt: 0.241 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 9.5 V
  • Break down voltage: 9.9 V
  • Plasma total charge: 17.5 C
  • Ohmic heating power: 19.0 kW
  • Q edge: 10.9
  • Central electron temperature: 31.8 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and