Golem shot: 4240

2010-12-02 - 174413

Basic parameters:
  • Chamber pressure pchamber : 21.06->20.66 mPa (request: 20 mPa)
  • Chamber temperature: 11 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 75 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 7,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6702 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.94 over 8.09 to 17.03 [ms]
  • Mean toroidal magnetic field Bt: 0.265 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 5.7 V
  • Break down voltage: 8.4 V
  • Plasma total charge: 9.9 C
  • Ohmic heating power: 6.8 kW
  • Q edge: 19.9
  • Central electron temperature: 31.8 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and