Golem shot: 4241

2010-12-02 - 174659

Basic parameters:
  • Chamber pressure pchamber : 20.82->20.27 mPa (request: 20 mPa)
  • Chamber temperature: 9 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 75 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 7,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6865 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.86 over 8.13 to 16.99 [ms]
  • Mean toroidal magnetic field Bt: 0.259 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: 5.7 V
  • Break down voltage: 8.5 V
  • Plasma total charge: 10.2 C
  • Ohmic heating power: 7.4 kW
  • Q edge: 18.0
  • Central electron temperature: 33.5 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and