Golem shot: 4255

2010-12-02 - 182246

Basic parameters:
  • Chamber pressure pchamber : 1.96->19.96 mPa (request: 20 mPa)
  • Chamber temperature: 10 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 75 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 130 V, triggered 9,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 9013 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.79 over 10.38 to 19.17 [ms]
  • Mean toroidal magnetic field Bt: 0.268 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 5.6 V
  • Break down voltage: 8.5 V
  • Plasma total charge: 14.9 C
  • Ohmic heating power: 7.8 kW
  • Q edge: 17.3
  • Central electron temperature: 35.6 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and