Golem shot: 4256

2010-12-02 - 182443

Basic parameters:
  • Chamber pressure pchamber : 1.91->20.35 mPa (request: 20 mPa)
  • Chamber temperature: 8 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 75 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 9,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 9132 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.9 over 10.6 to 19.5 [ms]
  • Mean toroidal magnetic field Bt: 0.273 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: 5.4 V
  • Break down voltage: 8.3 V
  • Plasma total charge: 13.8 C
  • Ohmic heating power: 7.0 kW
  • Q edge: 19.0
  • Central electron temperature: 34.8 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and