Golem shot: 4263

2010-12-03 - 105328

Basic parameters:
  • Chamber pressure pchamber : 1.66->18.35 mPa (request: 20 mPa)
  • Chamber temperature: 8 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1223 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.52 over 7.93 to 17.45 [ms]
  • Mean toroidal magnetic field Bt: 0.155 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 7.1 V
  • Break down voltage: 9.6 V
  • Plasma total charge: 11.1 C
  • Ohmic heating power: 9.9 kW
  • Q edge: 10.0
  • Central electron temperature: 30.4 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and